مینی پی ال سی زلیو اشنایدر

فیلترها

دسته‌بندی را انتخاب کنید

SR2PACK2BD

  • Reverse polarity protection
  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • CSA, C-Tick, GOST, GL and UL certified

 

  • Range of productZelio Logic
    Product or component typeCompact discovery packs
    Discrete input number12 conforming to EN/IEC 61131-2 type 1
    Number of outputs8 relay
    kit compositionSR2B201BD
    Cable PC SR2USB01 for connection to PC
    Input/output number20
    local displayWith
    Number or control scheme lines120 with ladder programming
    0…200 with FBD programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V
    Supply voltage limits19.2…30 V
    Maximum supply current100 mA (without extension)
    Power dissipation in W6 W without extension
    Reverse polarity protectionWith
    Discrete input typeResistive
    Discrete input voltage24 V DC
    Discrete input current4 mA
    Counting frequency1 kHz for discrete input
    Voltage state 1 guaranteed>= 15 V for I1…IA and IH…IR discrete input circuit
    >= 15 V for IB…IG used as discrete input circuit
    Voltage state 0 guaranteed<= 5 V for I1…IA and IH…IR discrete input circuit
    <= 5 V for IB…IG used as discrete input circuit
    Current state 1 guaranteed>= 1.2 mA (IB…IG used as discrete input circuit)
    >= 2.2 mA (I1…IA and IH…IR discrete input circuit)
    Current state 0 guaranteed<= 0.5 mA (IB…IG used as discrete input circuit)
    Input compatibility3-wire proximity sensors PNP for discrete input
    Analogue input number2
    Analogue input typeCommon mode
    Analogue input range0…10 V
    0…24 V
    Temperature probe typeNTC 10k at 25 °C
    NTC 1000k at 25 °C
    KTY81 210/220/221/222/250
    Pt 500
    Maximum permissible voltage30 V for analogue input circuit
    Analogue input resolution8 bits
    LSB value39 mV for analogue input circuit
    Conversion timeSmart relay cycle time for analogue input circuit
    Conversion error+/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
    Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    Input impedance12 kOhm for IB…IG used as analogue input circuit
    12 kOhm for IB…IG used as discrete input circuit
    7.4 kOhm for I1…IA and IH…IR discrete input circuit
    Output voltage limits24…250 V AC (relay output)
    5…30 V DC (relay output)
    Contacts type and compositionNO for relay output
    Output thermal current8 A for all 8 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWithout
    Response time10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.7 kg
    Immunity to microbreaks1 ms
    Product certificationsGOST
    C-Tick
    UL
    GL
    CSA
    StandardsEN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-3
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-11
    EN/IEC 61000-4-12
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-5
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-4 level 3
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.2 cm
    Package 1 Width15.3 cm
    Package 1 Length23.3 cm
    Package 1 Weight502 g
    Unit Type of Package 2S03
    Number of Units in Package 210
    Package 2 Height30 cm
    Package 2 Width30 cm
    Package 2 Length40 cm
    Package 2 Weight5.516 kg

SR2PACK2FU

  • It offers about 5,00,000 cycles of electrical durability
  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • Wide range of operating temperature from -20°C to 55°C

 

  • Range of productZelio Logic
    Product or component typeCompact discovery packs
    Discrete input number12
    Number of outputs8 relay
    kit compositionSR2B201FU
    Cable PC SR2USB01 for connection to PC
    Input/output number20
    local displayWith
    Number or control scheme lines120 with ladder programming
    0…200 with FBD programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage100…240 V
    Supply voltage limits85…264 V
    Supply frequency50/60 Hz
    Maximum supply current100 mA at 100 V (without extension)
    50 mA at 240 V (without extension)
    Power consumption in VA11 VA without extension
    Isolation voltage1780 V
    Protection typeAgainst inversion of terminals (control instructions not executed)
    Discrete input voltage100…240 V AC
    Discrete input current0.6 mA
    Discrete input frequency57…63 Hz
    47…53 Hz
    Voltage state 1 guaranteed>= 79 V for discrete input
    Voltage state 0 guaranteed<= 40 V for discrete input
    Current state 1 guaranteed>= 0.17 mA (discrete input)
    Current state 0 guaranteed<= 0.5 mA (discrete input)
    Input impedance350 kOhm for discrete input
    Output voltage limits5…30 V DC (relay output)
    24…250 V AC
    Contacts type and compositionNO for relay output
    Output thermal current8 A for all 8 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWithout
    Response time50 ms with ladder programming (from state 0 to state 1) for discrete input
    50 ms with ladder programming (from state 1 to state 0) for discrete input
    50…255 ms with FBD programming (from state 0 to state 1) for discrete input
    50…255 ms with FBD programming (from state 1 to state 0) for discrete input
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.85 kg
    Immunity to microbreaks10 ms
    Product certificationsUL
    C-Tick
    GL
    CSA
    GOST
    StandardsEN/IEC 61000-4-2 level 3
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-5
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-3
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-11
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.2 cm
    Package 1 Width15.3 cm
    Package 1 Length23.2 cm
    Package 1 Weight599 g
    Unit Type of Package 2S03
    Number of Units in Package 210
    Package 2 Height30 cm
    Package 2 Width30 cm
    Package 2 Length40 cm
    Package 2 Weight6.613 kg

SR2PACKBD

  • Reverse polarity protection
  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • CSA, C-Tick, GOST, GL and UL certified

 

  • Range of productZelio Logic
    Product or component typeCompact discovery packs
    Discrete input number8 conforming to EN/IEC 61131-2 type 1
    Number of outputs4 relay
    kit compositionSR2B121BD
    Cable PC SR2USB01 for connection to PC
    Input/output number12
    local displayWith
    Number or control scheme lines120 with ladder programming
    0…200 with FBD programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V
    Supply voltage limits19.2…30 V
    Maximum supply current100 mA (without extension)
    Power dissipation in W3 W without extension
    Reverse polarity protectionWith
    Discrete input typeResistive
    Discrete input voltage24 V DC
    Discrete input current4 mA
    Counting frequency1 kHz for discrete input
    Voltage state 1 guaranteed>= 15 V for I1…IA and IH…IR discrete input circuit
    >= 15 V for IB…IG used as discrete input circuit
    Voltage state 0 guaranteed<= 5 V for I1…IA and IH…IR discrete input circuit
    <= 5 V for IB…IG used as discrete input circuit
    Current state 1 guaranteed>= 1.2 mA (IB…IG used as discrete input circuit)
    >= 2.2 mA (I1…IA and IH…IR discrete input circuit)
    Current state 0 guaranteed<= 0.5 mA (IB…IG used as discrete input circuit)
    <= 0.75 mA (I1…IA and IH…IR discrete input circuit)
    Input compatibility3-wire proximity sensors PNP for discrete input
    Analogue input number4
    Analogue input typeCommon mode
    Analogue input range0…10 V
    0…24 V
    Temperature probe typeNTC 10k at 25 °C
    NTC 1000k at 25 °C
    KTY81 210/220/221/222/250
    Pt 500
    Maximum permissible voltage30 V for analogue input circuit
    Analogue input resolution8 bits
    LSB value39 mV for analogue input circuit
    Conversion timeSmart relay cycle time for analogue input circuit
    Conversion error+/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
    Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    Input impedance12 kOhm for IB…IG used as analogue input circuit
    12 kOhm for IB…IG used as discrete input circuit
    7.4 kOhm for I1…IA and IH…IR discrete input circuit
    Output voltage limits24…250 V AC (relay output)
    5…30 V DC (relay output)
    Contacts type and compositionNO for relay output
    Output thermal current8 A for all 4 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.7 kg
    Immunity to microbreaks1 ms
    Product certificationsCSA
    C-Tick
    UL
    GOST
    GL
    StandardsEN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-5
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-3
    EN/IEC 61000-4-11
    EN/IEC 60068-2-27 Ea
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.5 cm
    Package 1 Width15.5 cm
    Package 1 Length23.5 cm
    Package 1 Weight393.0 g
    Unit Type of Package 2S03
    Number of Units in Package 210
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight4.434 kg

SR2PACKFU

  • It offers about 5,00,000 cycles of electrical durability
  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • Wide range of operating temperature from -20°C to 55°C

 

  • Range of productZelio Logic
    Product or component typeCompact discovery packs
    Discrete input number8
    Number of outputs4 relay
    kit compositionSR2B121FU
    Cable PC SR2USB01 for connection to PC
    Input/output number12
    local displayWith
    Number or control scheme lines120 with ladder programming
    0…200 with FBD programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage100…240 V
    Supply voltage limits85…264 V
    Supply frequency50/60 Hz
    Maximum supply current30 mA at 240 V (without extension)
    80 mA at 100 V (without extension)
    Power consumption in VA7 VA without extension
    Isolation voltage1780 V
    Protection typeAgainst inversion of terminals (control instructions not executed)
    Discrete input voltage100…240 V AC
    Discrete input current0.6 mA
    Discrete input frequency47…53 Hz
    57…63 Hz
    Voltage state 1 guaranteed>= 79 V for discrete input
    Voltage state 0 guaranteed<= 40 V for discrete input
    Current state 1 guaranteed>= 0.17 mA (discrete input)
    Current state 0 guaranteed<= 0.5 mA (discrete input)
    Input impedance350 kOhm for discrete input
    Output voltage limits5…30 V DC (relay output)
    24…250 V AC
    Contacts type and compositionNO for relay output
    Output thermal current8 A for all 4 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time50 ms with ladder programming (from state 0 to state 1) for discrete input
    50 ms with ladder programming (from state 1 to state 0) for discrete input
    50…255 ms with FBD programming (from state 0 to state 1) for discrete input
    50…255 ms with FBD programming (from state 1 to state 0) for discrete input
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.7 kg
    Immunity to microbreaks10 ms
    Product certificationsGOST
    CSA
    UL
    C-Tick
    GL
    StandardsEN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-11
    EN/IEC 61000-4-3
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-6 level 3
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-5
    EN/IEC 61000-4-4 level 3
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.5 cm
    Package 1 Width15.5 cm
    Package 1 Length23.5 cm
    Package 1 Weight499 g
    Unit Type of Package 2S03
    Number of Units in Package 210
    Package 2 Height30 cm
    Package 2 Width30 cm
    Package 2 Length40 cm
    Package 2 Weight4.99 kg

SR2SFT01

  • Range of productZelio Logic
    Product or component typeProgramming software
    Product compatibilityZelio Logic compact and modular smart relay
    Software designationZelio Soft 2 multi-language
    Software versionV5.4.0
    Operating systemWindows 7 32/64 bit (V5.4.0 and older software versions)multilingual
    Windows 8.1 32/64 bit (V5.4.0 and older software versions)multilingual
    Windows 10 32/64 bit (V5.4.0 and older software versions)multilingual
    FormatCD
    Software functionFDB language program editor
    Ladder language program editor
    Net weight0.2 kg

SR2SFT02

Range of productZelio Logic
Software designationZelio Logic Alarm
Software typeProgramming software
languageMultilingual
FormatCD-ROM
Operating systemWindows 7 64 bits
Windows 7 32 bit
Windows 10 64 bit
Windows 10 32 bit
Windows 8.1 32/64 bit
Net weight0.2 kg

SR2USB01

  • Range of productZelio Logic
    Accessory / separate part typeConnecting cable
    accessory / separate part categoryConnection accessories
    Accessory / separate part destinationFor smart relay
    Product specific applicationTo be used with Zelio Soft software
    To connect the relay to the PC
    Operating systemWindows 7
    Windows Vista
    Windows XP
    Cable length3 m
    Connector typeUSB
    Net weight0.1 kg
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height3.000 cm
    Package 1 Width14.500 cm
    Package 1 Length13.000 cm
    Package 1 Weight81.000 g
    Unit Type of Package 2S02
    Number of Units in Package 220
    Package 2 Height15.000 cm
    Package 2 Width30.000 cm
    Package 2 Length40.000 cm
    Package 2 Weight1.907 kg

SR3B101BD

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeModular smart relay
    local displayWith
    Number or control scheme lines0…500 with FBD programming
    0…240 with ladder programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V
    Supply voltage limits19.2…30 V
    Maximum supply current100 mA (with extensions)
    100 mA (without extension)
    Power dissipation in W3 W without extension
    8 W with extensions
    Reverse polarity protectionWith
    Discrete input number6 conforming to EN/IEC 61131-2 type 1
    Discrete input typeResistive
    Discrete input voltage24 V DC
    Discrete input current4 mA
    Counting frequency1 kHz for discrete input
    Voltage state 1 guaranteed>= 15 V for I1…IA and IH…IR discrete input circuit
    >= 15 V for IB…IG used as discrete input circuit
    Voltage state 0 guaranteed<= 5 V for I1…IA and IH…IR discrete input circuit
    <= 5 V for IB…IG used as discrete input circuit
    <= 5 V
    Current state 1 guaranteed>= 1.2 mA (IB…IG used as discrete input circuit)
    >= 2.2 mA (I1…IA and IH…IR discrete input circuit)
    Current state 0 guaranteed<= 0.5 mA (IB…IG used as discrete input circuit)
    <= 0.75 mA (I1…IA and IH…IR discrete input circuit)
    Input compatibility3-wire proximity sensors PNP for discrete input
    Analogue input number4
    Analogue input typeCommon mode
    Analogue input range0…10 V
    0…24 V
    Temperature probe typeNTC 10k at 25 °C
    NTC 1000k at 25 °C
    KTY81 210/220/221/222/250
    Pt 500
    Maximum permissible voltage30 V for analogue input circuit
    Analogue input resolution8 bits
    LSB value39 mV for analogue input circuit
    Conversion timeSmart relay cycle time for analogue input circuit
    Conversion error+/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
    Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    Input impedance12 kOhm for IB…IG used as analogue input circuit
    12 kOhm for IB…IG used as discrete input circuit
    7.4 kOhm for I1…IA and IH…IR discrete input circuit
    Number of outputs4 relay
    Output voltage limits24…250 V AC (relay output)
    5…30 V DC (relay output)
    Contacts type and compositionNO for relay output
    Output thermal current8 A for all 4 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.25 kg
    Immunity to microbreaks1 ms
    Product certificationsGOST
    UL
    C-Tick
    CSA
    GL
    StandardsEN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-11
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-3
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-5
    EN/IEC 61000-4-12
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.86 cm
    Package 1 Width8.89 cm
    Package 1 Length10.16 cm
    Package 1 Weight0.25 kg
    Unit Type of Package 2S03
    Number of Units in Package 230
    Package 2 Height30 cm
    Package 2 Width30 cm
    Package 2 Length40 cm
    Package 2 Weight7.605 kg

SR3B101FU

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeModular smart relay
    local displayWith
    Number or control scheme lines0…500 with FBD programming
    0…240 with ladder programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage100…240 V
    Supply voltage limits85…264 V
    Supply frequency50/60 Hz
    Maximum supply current30 mA at 240 V (without extension)
    40 mA at 240 V (with extensions)
    80 mA at 100 V (with extensions)
    80 mA at 100 V (without extension)
    Power consumption in VA12 VA with extensions
    7 VA without extension
    Isolation voltage1780 V
    Protection typeAgainst inversion of terminals (control instructions not executed)
    Discrete input number6
    Discrete input voltage100…240 V AC
    Discrete input current0.6 mA
    Discrete input frequency57…63 Hz
    47…53 Hz
    Voltage state 1 guaranteed>= 79 V for discrete input
    Voltage state 0 guaranteed<= 40 V for discrete input
    Current state 1 guaranteed>= 0.17 mA (discrete input)
    Current state 0 guaranteed<= 0.5 mA (discrete input)
    Input impedance350 kOhm for discrete input
    Number of outputs4 relay
    Output voltage limits5…30 V DC (relay output)
    24…250 V AC
    Contacts type and compositionNO for relay output
    Output thermal current8 A for all 4 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time50 ms with ladder programming (from state 0 to state 1) for discrete input
    50 ms with ladder programming (from state 1 to state 0) for discrete input
    50…255 ms with FBD programming (from state 0 to state 1) for discrete input
    50…255 ms with FBD programming (from state 1 to state 0) for discrete input
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.25 kg
    Immunity to microbreaks10 ms
    Product certificationsGOST
    C-Tick
    CSA
    UL
    GL
    StandardsEN/IEC 61000-4-12
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-3
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-5
    EN/IEC 61000-4-11
    EN/IEC 60068-2-6 Fc
    EN/IEC 60068-2-27 Ea
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.8 cm
    Package 1 Width10 cm
    Package 1 Length9 cm
    Package 1 Weight242 g
    Unit Type of Package 2S03
    Number of Units in Package 230
    Package 2 Height30 cm
    Package 2 Width30 cm
    Package 2 Length40 cm
    Package 2 Weight7.738 kg

SR3B102BD

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeModular smart relay
    local displayWith
    Number or control scheme lines0…500 with FBD programming
    0…240 with ladder programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V
    Supply voltage limits19.2…30 V
    Maximum supply current160 mA (with extensions)
    50 mA (without extension)
    Power dissipation in W4 W without extension
    8 W with extensions
    Reverse polarity protectionWith
    Discrete input number6 conforming to EN/IEC 61131-2 type 1
    Discrete input typeResistive
    Discrete input voltage24 V DC
    Discrete input current4 mA
    Counting frequency1 kHz for discrete input
    Voltage state 1 guaranteed>= 15 V for I1…IA and IH…IR discrete input circuit
    >= 15 V for IB…IG used as discrete input circuit
    Voltage state 0 guaranteed<= 5 V for I1…IA and IH…IR discrete input circuit
    <= 5 V for IB…IG used as discrete input circuit
    Current state 1 guaranteed>= 1.2 mA (IB…IG used as discrete input circuit)
    >= 2.2 mA (I1…IA and IH…IR discrete input circuit)
    Current state 0 guaranteed<= 0.5 mA (IB…IG used as discrete input circuit)
    <= 0.75 mA (I1…IA and IH…IR discrete input circuit)
    Input compatibility3-wire proximity sensors PNP for discrete input
    Analogue input number4
    Analogue input typeCommon mode
    Analogue input range0…10 V
    0…24 V
    Temperature probe typeNTC 10k at 25 °C
    NTC 1000k at 25 °C
    KTY81 210/220/221/222/250
    Pt 500
    Maximum permissible voltage30 V for analogue input circuit
    Analogue input resolution8 bits
    LSB value39 mV for analogue input circuit
    Conversion timeSmart relay cycle time for analogue input circuit
    Conversion error+/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
    Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    Input impedance12 kOhm for IB…IG used as analogue input circuit
    12 kOhm for IB…IG used as discrete input circuit
    7.4 kOhm for I1…IA and IH…IR discrete input circuit
    Number of outputs4 transistor
    Output voltage24 V transistor output
    Output voltage limits19.2…30 V DC (transistor output)
    Load current0.5…0.625 A transistor output
    [Ures] residual voltage2 V at state 1 transistor output
    Overload protectionWith overload protection for transistor output
    Short-circuit protectionWith transistor output
    Overvoltage protectionWith overvoltage protection for transistor output
    ClockWith
    Response time<= 1 ms (from state 0 to state 1) for transistor output
    <= 1 ms (from state 1 to state 0) for transistor output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.22 kg
    Immunity to microbreaks1 ms
    Product certificationsGL
    C-Tick
    GOST
    UL
    CSA
    StandardsEN/IEC 60068-2-27 Ea
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-11
    EN/IEC 61000-4-3
    EN/IEC 61000-4-5
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.5 cm
    Package 1 Width10.0 cm
    Package 1 Length8.8 cm
    Package 1 Weight211.0 g
    Unit Type of Package 2S03
    Number of Units in Package 230
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight6.83 kg

SR3B261B

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeModular smart relay
    local displayWith
    Number or control scheme lines0…500 with FBD programming
    0…240 with ladder programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V
    Supply voltage limits20.4…28.8 V
    Supply frequency50/60 Hz
    Maximum supply current280 mA (without extension)
    415 mA (with extensions)
    Power consumption in VA10 VA with extensions
    7.5 VA without extension
    Isolation voltage1780 V
    Protection typeAgainst inversion of terminals (control instructions not executed)
    Discrete input number16
    Discrete input voltage24 V AC
    Discrete input current4.4 mA
    Discrete input frequency47…53 Hz
    57…63 Hz
    Voltage state 1 guaranteed>= 14 V for discrete input
    Voltage state 0 guaranteed<= 5 V for discrete input
    Current state 1 guaranteed>= 2 mA (discrete input)
    Current state 0 guaranteed<= 0.5 mA (discrete input)
    Input impedance4.6 kOhm for discrete input
    Number of outputs10 relay
    Output voltage limits5…30 V DC (relay output)
    24…250 V AC
    Contacts type and compositionNO for relay output
    Output thermal current5 A for 2 outputs for relay output
    8 A for 8 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time50 ms with ladder programming (from state 0 to state 1) for discrete input
    50 ms with ladder programming (from state 1 to state 0) for discrete input
    50…255 ms with FBD programming (from state 0 to state 1) for discrete input
    50…255 ms with FBD programming (from state 1 to state 0) for discrete input
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.4 kg
    Immunity to microbreaks10 ms repeated 20 times
    Product certificationsGOST
    GL
    UL
    CSA
    C-Tick
    StandardsEN/IEC 61000-4-5
    EN/IEC 61000-4-11
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-6 level 3
    EN/IEC 60068-2-6 Fc
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-3
    EN/IEC 61000-4-12
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.8 cm
    Package 1 Width10.0 cm
    Package 1 Length13.5 cm
    Package 1 Weight383.0 g
    Unit Type of Package 2S03
    Number of Units in Package 220
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight8.204 kg

SR3B261BD

  • Range of ProductZelio Logic
    Product or Component TypeModular smart relay
    local displayWith
    Number or control scheme lines0…500 FBD
    0…240 ladder
    Cycle time6…90 ms
    Backup time10 years 77 °F (25 °C)
    Clock drift12 min/year 32…131 °F (0…55 °C)
    6 s/month 77 °F (25 °C)
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V
    Supply voltage limits19.2…30 V
    Maximum supply current190 mA without extension)
    300 mA with extensions)
    Power dissipation in W10 W with extensions
    6 W without extension
    Reverse polarity protectionWith
    Discrete input number16 EN/IEC 61131-2 type 1
    Discrete input typeResistive
    Discrete input voltage24 V DC
    Discrete input current4 mA
    Counting frequency1 kHz discrete input
    Voltage state 1 guaranteed>= 15 V I1…IA and IH…IR discrete input circuit
    >= 15 V IB…IG used as discrete input circuit
    Voltage state 0 guaranteed<= 5 V I1…IA and IH…IR discrete input circuit
    <= 5 V IB…IG used as discrete input circuit
    Current state 1 guaranteed>= 1.2 mA IB…IG used as discrete input circuit)
    >= 2.2 mA I1…IA and IH…IR discrete input circuit)
    Current state 0 guaranteed<= 0.5 mA IB…IG used as discrete input circuit)
    <= 0.75 mA I1…IA and IH…IR discrete input circuit)
    Input compatibility3-wire proximity sensors PNP discrete input
    Analogue input number6
    Analogue Input TypeCommon mode
    Analogue input range0…10 V
    0…24 V
    Temperature probe typeNTC 10k 77 °F (25 °C)
    NTC 1000k 77 °F (25 °C)
    KTY81 210/220/221/222/250
    Pt 500
    Maximum permissible voltage30 V analogue input circuit
    Analogue input resolution8 bits
    LSB value39 mV analogue input circuit
    Conversion timeSmart relay cycle time analogue input circuit
    Conversion error+/- 5 % 77 °F (25 °C) analogue input circuit
    +/- 6.2 % 131 °F (55 °C) analogue input circuit
    Repeat accuracy+/- 2 % 131 °F (55 °C) analogue input circuit
    Operating distance10 m between stations, with screened cable (sensor not isolated) analogue input circuit
    Input impedance12 kOhm IB…IG used as analogue input circuit
    12 kOhm IB…IG used as discrete input circuit
    7.4 kOhm I1…IA and IH…IR discrete input circuit
    Number of Outputs10 relay
    Output voltage limits24…250 V AC relay output)
    5…30 V DC relay output)
    Contacts type and compositionNO relay output
    Output thermal current5 A for 2 outputs relay output
    8 A for 8 outputs relay output
    Electrical durabilityAC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1
    AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1
    DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1
    DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA 12 V relay output)
    Operating rate in Hz0.1 Hz at Ie)relay output
    10 Hz no load)relay output
    Mechanical durability10000000 cycles relay output
    [Uimp] rated impulse withstand voltage4 kV EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time10 ms from state 0 to state 1)relay output
    5 ms from state 1 to state 0)relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² AWG 24…AWG 18) flexible with cable end
    Tightening torque4.43 lbf.in (0.5 N.m)
    Overvoltage categoryIII EN/IEC 60664-1
    Net Weight0.88 lb(US) (0.4 kg)
    Immunity to microbreaks1 ms
    Product CertificationsGL
    C-tick
    CSA
    UL
    GOST
    StandardsEN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-5
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-11
    EN/IEC 61000-4-3
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-12
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-4 level 3
    IP degree of protectionIP20 IEC 60529 terminal block)
    IP40 IEC 60529 front panel)
    Environmental characteristicEMC directive EN/IEC 61000-6-2
    EMC directive EN/IEC 61000-6-3
    EMC directive EN/IEC 61000-6-4
    EMC directive EN/IEC 61131-2 zone B
    Low voltage directive EN/IEC 61131-2
    Disturbance radiated/conductedClass B EN 55022-11 group 1
    Pollution degree2 EN/IEC 61131-2
    Ambient air temperature for operation-4…104 °F (-20…40 °C) in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2
    -4…131 °F (-20…55 °C) IEC 60068-2-1 and IEC 60068-2-2
    Ambient Air Temperature for Storage-40…158 °F (-40…70 °C)
    Operating altitude6561.68 ft (2000 m)
    Maximum altitude transport10000.00 ft (3048 m)
    Relative Humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height2.68 in (6.8 cm)
    Package 1 Width3.94 in (10.0 cm)
    Package 1 Length5.31 in (13.5 cm)
    Package 1 Weight13.44 oz (381.0 g)
    Unit Type of Package 2S03
    Number of Units in Package 220
    Package 2 Height11.81 in (30.0 cm)
    Package 2 Width11.81 in (30.0 cm)
    Package 2 Length15.75 in (40.0 cm)
    Package 2 Weight17.84 lb(US) (8.094 kg)
فروشگاه