SR2PACK2BD
- Reverse polarity protection
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- CSA, C-Tick, GOST, GL and UL certified
-
Range of product Zelio Logic Product or component type Compact discovery packs Discrete input number 12 conforming to EN/IEC 61131-2 type 1 Number of outputs 8 relay kit composition SR2B201BD
Cable PC SR2USB01 for connection to PCInput/output number 20 local display With Number or control scheme lines 120 with ladder programming
0…200 with FBD programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 24 V Supply voltage limits 19.2…30 V Maximum supply current 100 mA (without extension) Power dissipation in W 6 W without extension Reverse polarity protection With Discrete input type Resistive Discrete input voltage 24 V DC Discrete input current 4 mA Counting frequency 1 kHz for discrete input Voltage state 1 guaranteed >= 15 V for I1…IA and IH…IR discrete input circuit
>= 15 V for IB…IG used as discrete input circuitVoltage state 0 guaranteed <= 5 V for I1…IA and IH…IR discrete input circuit
<= 5 V for IB…IG used as discrete input circuitCurrent state 1 guaranteed >= 1.2 mA (IB…IG used as discrete input circuit)
>= 2.2 mA (I1…IA and IH…IR discrete input circuit)Current state 0 guaranteed <= 0.5 mA (IB…IG used as discrete input circuit) Input compatibility 3-wire proximity sensors PNP for discrete input Analogue input number 2 Analogue input type Common mode Analogue input range 0…10 V
0…24 VTemperature probe type NTC 10k at 25 °C
NTC 1000k at 25 °C
KTY81 210/220/221/222/250
Pt 500Maximum permissible voltage 30 V for analogue input circuit Analogue input resolution 8 bits LSB value 39 mV for analogue input circuit Conversion time Smart relay cycle time for analogue input circuit Conversion error +/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuitRepeat accuracy +/- 2 % at 55 °C for analogue input circuit Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit Input impedance 12 kOhm for IB…IG used as analogue input circuit
12 kOhm for IB…IG used as discrete input circuit
7.4 kOhm for I1…IA and IH…IR discrete input circuitOutput voltage limits 24…250 V AC (relay output)
5…30 V DC (relay output)Contacts type and composition NO for relay output Output thermal current 8 A for all 8 outputs for relay output Electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock Without Response time 10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.7 kg Immunity to microbreaks 1 ms Product certifications GOST
C-Tick
UL
GL
CSAStandards EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-3
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-11
EN/IEC 61000-4-12
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-5
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-4 level 3IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.2 cm Package 1 Width 15.3 cm Package 1 Length 23.3 cm Package 1 Weight 502 g Unit Type of Package 2 S03 Number of Units in Package 2 10 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 5.516 kg
SR2PACK2FU
- It offers about 5,00,000 cycles of electrical durability
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- Wide range of operating temperature from -20°C to 55°C
-
Range of product Zelio Logic Product or component type Compact discovery packs Discrete input number 12 Number of outputs 8 relay kit composition SR2B201FU
Cable PC SR2USB01 for connection to PCInput/output number 20 local display With Number or control scheme lines 120 with ladder programming
0…200 with FBD programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 100…240 V Supply voltage limits 85…264 V Supply frequency 50/60 Hz Maximum supply current 100 mA at 100 V (without extension)
50 mA at 240 V (without extension)Power consumption in VA 11 VA without extension Isolation voltage 1780 V Protection type Against inversion of terminals (control instructions not executed) Discrete input voltage 100…240 V AC Discrete input current 0.6 mA Discrete input frequency 57…63 Hz
47…53 HzVoltage state 1 guaranteed >= 79 V for discrete input Voltage state 0 guaranteed <= 40 V for discrete input Current state 1 guaranteed >= 0.17 mA (discrete input) Current state 0 guaranteed <= 0.5 mA (discrete input) Input impedance 350 kOhm for discrete input Output voltage limits 5…30 V DC (relay output)
24…250 V ACContacts type and composition NO for relay output Output thermal current 8 A for all 8 outputs for relay output Electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock Without Response time 50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50…255 ms with FBD programming (from state 0 to state 1) for discrete input
50…255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.85 kg Immunity to microbreaks 10 ms Product certifications UL
C-Tick
GL
CSA
GOSTStandards EN/IEC 61000-4-2 level 3
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-5
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-3
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-12
EN/IEC 61000-4-11IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.2 cm Package 1 Width 15.3 cm Package 1 Length 23.2 cm Package 1 Weight 599 g Unit Type of Package 2 S03 Number of Units in Package 2 10 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 6.613 kg
SR2PACKBD
- Reverse polarity protection
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- CSA, C-Tick, GOST, GL and UL certified
-
Range of product Zelio Logic Product or component type Compact discovery packs Discrete input number 8 conforming to EN/IEC 61131-2 type 1 Number of outputs 4 relay kit composition SR2B121BD
Cable PC SR2USB01 for connection to PCInput/output number 12 local display With Number or control scheme lines 120 with ladder programming
0…200 with FBD programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 24 V Supply voltage limits 19.2…30 V Maximum supply current 100 mA (without extension) Power dissipation in W 3 W without extension Reverse polarity protection With Discrete input type Resistive Discrete input voltage 24 V DC Discrete input current 4 mA Counting frequency 1 kHz for discrete input Voltage state 1 guaranteed >= 15 V for I1…IA and IH…IR discrete input circuit
>= 15 V for IB…IG used as discrete input circuitVoltage state 0 guaranteed <= 5 V for I1…IA and IH…IR discrete input circuit
<= 5 V for IB…IG used as discrete input circuitCurrent state 1 guaranteed >= 1.2 mA (IB…IG used as discrete input circuit)
>= 2.2 mA (I1…IA and IH…IR discrete input circuit)Current state 0 guaranteed <= 0.5 mA (IB…IG used as discrete input circuit)
<= 0.75 mA (I1…IA and IH…IR discrete input circuit)Input compatibility 3-wire proximity sensors PNP for discrete input Analogue input number 4 Analogue input type Common mode Analogue input range 0…10 V
0…24 VTemperature probe type NTC 10k at 25 °C
NTC 1000k at 25 °C
KTY81 210/220/221/222/250
Pt 500Maximum permissible voltage 30 V for analogue input circuit Analogue input resolution 8 bits LSB value 39 mV for analogue input circuit Conversion time Smart relay cycle time for analogue input circuit Conversion error +/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuitRepeat accuracy +/- 2 % at 55 °C for analogue input circuit Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit Input impedance 12 kOhm for IB…IG used as analogue input circuit
12 kOhm for IB…IG used as discrete input circuit
7.4 kOhm for I1…IA and IH…IR discrete input circuitOutput voltage limits 24…250 V AC (relay output)
5…30 V DC (relay output)Contacts type and composition NO for relay output Output thermal current 8 A for all 4 outputs for relay output Electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.7 kg Immunity to microbreaks 1 ms Product certifications CSA
C-Tick
UL
GOST
GLStandards EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-12
EN/IEC 61000-4-5
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-11
EN/IEC 60068-2-27 EaIP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.5 cm Package 1 Width 15.5 cm Package 1 Length 23.5 cm Package 1 Weight 393.0 g Unit Type of Package 2 S03 Number of Units in Package 2 10 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 4.434 kg
SR2PACKFU
- It offers about 5,00,000 cycles of electrical durability
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- Wide range of operating temperature from -20°C to 55°C
-
Range of product Zelio Logic Product or component type Compact discovery packs Discrete input number 8 Number of outputs 4 relay kit composition SR2B121FU
Cable PC SR2USB01 for connection to PCInput/output number 12 local display With Number or control scheme lines 120 with ladder programming
0…200 with FBD programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 100…240 V Supply voltage limits 85…264 V Supply frequency 50/60 Hz Maximum supply current 30 mA at 240 V (without extension)
80 mA at 100 V (without extension)Power consumption in VA 7 VA without extension Isolation voltage 1780 V Protection type Against inversion of terminals (control instructions not executed) Discrete input voltage 100…240 V AC Discrete input current 0.6 mA Discrete input frequency 47…53 Hz
57…63 HzVoltage state 1 guaranteed >= 79 V for discrete input Voltage state 0 guaranteed <= 40 V for discrete input Current state 1 guaranteed >= 0.17 mA (discrete input) Current state 0 guaranteed <= 0.5 mA (discrete input) Input impedance 350 kOhm for discrete input Output voltage limits 5…30 V DC (relay output)
24…250 V ACContacts type and composition NO for relay output Output thermal current 8 A for all 4 outputs for relay output Electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50…255 ms with FBD programming (from state 0 to state 1) for discrete input
50…255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.7 kg Immunity to microbreaks 10 ms Product certifications GOST
CSA
UL
C-Tick
GLStandards EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-12
EN/IEC 61000-4-11
EN/IEC 61000-4-3
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-6 level 3
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-5
EN/IEC 61000-4-4 level 3IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.5 cm Package 1 Width 15.5 cm Package 1 Length 23.5 cm Package 1 Weight 499 g Unit Type of Package 2 S03 Number of Units in Package 2 10 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 4.99 kg
SR2SFT01
-
Range of product Zelio Logic Product or component type Programming software Product compatibility Zelio Logic compact and modular smart relay Software designation Zelio Soft 2 multi-language Software version V5.4.0 Operating system Windows 7 32/64 bit (V5.4.0 and older software versions)multilingual
Windows 8.1 32/64 bit (V5.4.0 and older software versions)multilingual
Windows 10 32/64 bit (V5.4.0 and older software versions)multilingualFormat CD Software function FDB language program editor
Ladder language program editorNet weight 0.2 kg
SR2SFT02
Range of product Zelio Logic Software designation Zelio Logic Alarm Software type Programming software language Multilingual Format CD-ROM Operating system Windows 7 64 bits
Windows 7 32 bit
Windows 10 64 bit
Windows 10 32 bit
Windows 8.1 32/64 bit
Net weight 0.2 kg
SR2USB01
-
Range of product Zelio Logic Accessory / separate part type Connecting cable accessory / separate part category Connection accessories Accessory / separate part destination For smart relay Product specific application To be used with Zelio Soft software
To connect the relay to the PCOperating system Windows 7
Windows Vista
Windows XPCable length 3 m Connector type USB Net weight 0.1 kg Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 3.000 cm Package 1 Width 14.500 cm Package 1 Length 13.000 cm Package 1 Weight 81.000 g Unit Type of Package 2 S02 Number of Units in Package 2 20 Package 2 Height 15.000 cm Package 2 Width 30.000 cm Package 2 Length 40.000 cm Package 2 Weight 1.907 kg
SR3B101BD
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- More I/O than SR2 model, for larger applications
-
Range of product Zelio Logic Product or component type Modular smart relay local display With Number or control scheme lines 0…500 with FBD programming
0…240 with ladder programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 24 V Supply voltage limits 19.2…30 V Maximum supply current 100 mA (with extensions)
100 mA (without extension)Power dissipation in W 3 W without extension
8 W with extensionsReverse polarity protection With Discrete input number 6 conforming to EN/IEC 61131-2 type 1 Discrete input type Resistive Discrete input voltage 24 V DC Discrete input current 4 mA Counting frequency 1 kHz for discrete input Voltage state 1 guaranteed >= 15 V for I1…IA and IH…IR discrete input circuit
>= 15 V for IB…IG used as discrete input circuitVoltage state 0 guaranteed <= 5 V for I1…IA and IH…IR discrete input circuit
<= 5 V for IB…IG used as discrete input circuit
<= 5 VCurrent state 1 guaranteed >= 1.2 mA (IB…IG used as discrete input circuit)
>= 2.2 mA (I1…IA and IH…IR discrete input circuit)Current state 0 guaranteed <= 0.5 mA (IB…IG used as discrete input circuit)
<= 0.75 mA (I1…IA and IH…IR discrete input circuit)Input compatibility 3-wire proximity sensors PNP for discrete input Analogue input number 4 Analogue input type Common mode Analogue input range 0…10 V
0…24 VTemperature probe type NTC 10k at 25 °C
NTC 1000k at 25 °C
KTY81 210/220/221/222/250
Pt 500Maximum permissible voltage 30 V for analogue input circuit Analogue input resolution 8 bits LSB value 39 mV for analogue input circuit Conversion time Smart relay cycle time for analogue input circuit Conversion error +/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuitRepeat accuracy +/- 2 % at 55 °C for analogue input circuit Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit Input impedance 12 kOhm for IB…IG used as analogue input circuit
12 kOhm for IB…IG used as discrete input circuit
7.4 kOhm for I1…IA and IH…IR discrete input circuitNumber of outputs 4 relay Output voltage limits 24…250 V AC (relay output)
5…30 V DC (relay output)Contacts type and composition NO for relay output Output thermal current 8 A for all 4 outputs for relay output Electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.25 kg Immunity to microbreaks 1 ms Product certifications GOST
UL
C-Tick
CSA
GLStandards EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-11
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-12IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.86 cm Package 1 Width 8.89 cm Package 1 Length 10.16 cm Package 1 Weight 0.25 kg Unit Type of Package 2 S03 Number of Units in Package 2 30 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 7.605 kg
SR3B101FU
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- More I/O than SR2 model, for larger applications
-
Range of product Zelio Logic Product or component type Modular smart relay local display With Number or control scheme lines 0…500 with FBD programming
0…240 with ladder programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 100…240 V Supply voltage limits 85…264 V Supply frequency 50/60 Hz Maximum supply current 30 mA at 240 V (without extension)
40 mA at 240 V (with extensions)
80 mA at 100 V (with extensions)
80 mA at 100 V (without extension)Power consumption in VA 12 VA with extensions
7 VA without extensionIsolation voltage 1780 V Protection type Against inversion of terminals (control instructions not executed) Discrete input number 6 Discrete input voltage 100…240 V AC Discrete input current 0.6 mA Discrete input frequency 57…63 Hz
47…53 HzVoltage state 1 guaranteed >= 79 V for discrete input Voltage state 0 guaranteed <= 40 V for discrete input Current state 1 guaranteed >= 0.17 mA (discrete input) Current state 0 guaranteed <= 0.5 mA (discrete input) Input impedance 350 kOhm for discrete input Number of outputs 4 relay Output voltage limits 5…30 V DC (relay output)
24…250 V ACContacts type and composition NO for relay output Output thermal current 8 A for all 4 outputs for relay output Electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50…255 ms with FBD programming (from state 0 to state 1) for discrete input
50…255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.25 kg Immunity to microbreaks 10 ms Product certifications GOST
C-Tick
CSA
UL
GLStandards EN/IEC 61000-4-12
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-11
EN/IEC 60068-2-6 Fc
EN/IEC 60068-2-27 EaIP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.8 cm Package 1 Width 10 cm Package 1 Length 9 cm Package 1 Weight 242 g Unit Type of Package 2 S03 Number of Units in Package 2 30 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 7.738 kg
SR3B102BD
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- More I/O than SR2 model, for larger applications
-
Range of product Zelio Logic Product or component type Modular smart relay local display With Number or control scheme lines 0…500 with FBD programming
0…240 with ladder programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 24 V Supply voltage limits 19.2…30 V Maximum supply current 160 mA (with extensions)
50 mA (without extension)Power dissipation in W 4 W without extension
8 W with extensionsReverse polarity protection With Discrete input number 6 conforming to EN/IEC 61131-2 type 1 Discrete input type Resistive Discrete input voltage 24 V DC Discrete input current 4 mA Counting frequency 1 kHz for discrete input Voltage state 1 guaranteed >= 15 V for I1…IA and IH…IR discrete input circuit
>= 15 V for IB…IG used as discrete input circuitVoltage state 0 guaranteed <= 5 V for I1…IA and IH…IR discrete input circuit
<= 5 V for IB…IG used as discrete input circuitCurrent state 1 guaranteed >= 1.2 mA (IB…IG used as discrete input circuit)
>= 2.2 mA (I1…IA and IH…IR discrete input circuit)Current state 0 guaranteed <= 0.5 mA (IB…IG used as discrete input circuit)
<= 0.75 mA (I1…IA and IH…IR discrete input circuit)Input compatibility 3-wire proximity sensors PNP for discrete input Analogue input number 4 Analogue input type Common mode Analogue input range 0…10 V
0…24 VTemperature probe type NTC 10k at 25 °C
NTC 1000k at 25 °C
KTY81 210/220/221/222/250
Pt 500Maximum permissible voltage 30 V for analogue input circuit Analogue input resolution 8 bits LSB value 39 mV for analogue input circuit Conversion time Smart relay cycle time for analogue input circuit Conversion error +/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuitRepeat accuracy +/- 2 % at 55 °C for analogue input circuit Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit Input impedance 12 kOhm for IB…IG used as analogue input circuit
12 kOhm for IB…IG used as discrete input circuit
7.4 kOhm for I1…IA and IH…IR discrete input circuitNumber of outputs 4 transistor Output voltage 24 V transistor output Output voltage limits 19.2…30 V DC (transistor output) Load current 0.5…0.625 A transistor output [Ures] residual voltage 2 V at state 1 transistor output Overload protection With overload protection for transistor output Short-circuit protection With transistor output Overvoltage protection With overvoltage protection for transistor output Clock With Response time <= 1 ms (from state 0 to state 1) for transistor output
<= 1 ms (from state 1 to state 0) for transistor outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.22 kg Immunity to microbreaks 1 ms Product certifications GL
C-Tick
GOST
UL
CSAStandards EN/IEC 60068-2-27 Ea
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-12
EN/IEC 61000-4-11
EN/IEC 61000-4-3
EN/IEC 61000-4-5IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.5 cm Package 1 Width 10.0 cm Package 1 Length 8.8 cm Package 1 Weight 211.0 g Unit Type of Package 2 S03 Number of Units in Package 2 30 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 6.83 kg
SR3B261B
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- More I/O than SR2 model, for larger applications
-
Range of product Zelio Logic Product or component type Modular smart relay local display With Number or control scheme lines 0…500 with FBD programming
0…240 with ladder programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 24 V Supply voltage limits 20.4…28.8 V Supply frequency 50/60 Hz Maximum supply current 280 mA (without extension)
415 mA (with extensions)Power consumption in VA 10 VA with extensions
7.5 VA without extensionIsolation voltage 1780 V Protection type Against inversion of terminals (control instructions not executed) Discrete input number 16 Discrete input voltage 24 V AC Discrete input current 4.4 mA Discrete input frequency 47…53 Hz
57…63 HzVoltage state 1 guaranteed >= 14 V for discrete input Voltage state 0 guaranteed <= 5 V for discrete input Current state 1 guaranteed >= 2 mA (discrete input) Current state 0 guaranteed <= 0.5 mA (discrete input) Input impedance 4.6 kOhm for discrete input Number of outputs 10 relay Output voltage limits 5…30 V DC (relay output)
24…250 V ACContacts type and composition NO for relay output Output thermal current 5 A for 2 outputs for relay output
8 A for 8 outputs for relay outputElectrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50…255 ms with FBD programming (from state 0 to state 1) for discrete input
50…255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.4 kg Immunity to microbreaks 10 ms repeated 20 times Product certifications GOST
GL
UL
CSA
C-TickStandards EN/IEC 61000-4-5
EN/IEC 61000-4-11
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-6 level 3
EN/IEC 60068-2-6 Fc
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-12IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.8 cm Package 1 Width 10.0 cm Package 1 Length 13.5 cm Package 1 Weight 383.0 g Unit Type of Package 2 S03 Number of Units in Package 2 20 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 8.204 kg
SR3B261BD
-
Range of Product Zelio Logic Product or Component Type Modular smart relay local display With Number or control scheme lines 0…500 FBD
0…240 ladderCycle time 6…90 ms Backup time 10 years 77 °F (25 °C) Clock drift 12 min/year 32…131 °F (0…55 °C)
6 s/month 77 °F (25 °C)Checks Program memory on each power up [Us] rated supply voltage 24 V Supply voltage limits 19.2…30 V Maximum supply current 190 mA without extension)
300 mA with extensions)Power dissipation in W 10 W with extensions
6 W without extensionReverse polarity protection With Discrete input number 16 EN/IEC 61131-2 type 1 Discrete input type Resistive Discrete input voltage 24 V DC Discrete input current 4 mA Counting frequency 1 kHz discrete input Voltage state 1 guaranteed >= 15 V I1…IA and IH…IR discrete input circuit
>= 15 V IB…IG used as discrete input circuitVoltage state 0 guaranteed <= 5 V I1…IA and IH…IR discrete input circuit
<= 5 V IB…IG used as discrete input circuitCurrent state 1 guaranteed >= 1.2 mA IB…IG used as discrete input circuit)
>= 2.2 mA I1…IA and IH…IR discrete input circuit)Current state 0 guaranteed <= 0.5 mA IB…IG used as discrete input circuit)
<= 0.75 mA I1…IA and IH…IR discrete input circuit)Input compatibility 3-wire proximity sensors PNP discrete input Analogue input number 6 Analogue Input Type Common mode Analogue input range 0…10 V
0…24 VTemperature probe type NTC 10k 77 °F (25 °C)
NTC 1000k 77 °F (25 °C)
KTY81 210/220/221/222/250
Pt 500Maximum permissible voltage 30 V analogue input circuit Analogue input resolution 8 bits LSB value 39 mV analogue input circuit Conversion time Smart relay cycle time analogue input circuit Conversion error +/- 5 % 77 °F (25 °C) analogue input circuit
+/- 6.2 % 131 °F (55 °C) analogue input circuitRepeat accuracy +/- 2 % 131 °F (55 °C) analogue input circuit Operating distance 10 m between stations, with screened cable (sensor not isolated) analogue input circuit Input impedance 12 kOhm IB…IG used as analogue input circuit
12 kOhm IB…IG used as discrete input circuit
7.4 kOhm I1…IA and IH…IR discrete input circuitNumber of Outputs 10 relay Output voltage limits 24…250 V AC relay output)
5…30 V DC relay output)Contacts type and composition NO relay output Output thermal current 5 A for 2 outputs relay output
8 A for 8 outputs relay outputElectrical durability AC-12 500000 cycles 230 V, 1.5 A relay output EN/IEC 60947-5-1
AC-15 500000 cycles 230 V, 0.9 A relay output EN/IEC 60947-5-1
DC-12 500000 cycles 24 V, 1.5 A relay output EN/IEC 60947-5-1
DC-13 500000 cycles 24 V, 0.6 A relay output EN/IEC 60947-5-1Switching capacity in mA >= 10 mA 12 V relay output) Operating rate in Hz 0.1 Hz at Ie)relay output
10 Hz no load)relay outputMechanical durability 10000000 cycles relay output [Uimp] rated impulse withstand voltage 4 kV EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 10 ms from state 0 to state 1)relay output
5 ms from state 1 to state 0)relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² AWG 24…AWG 18) flexible with cable endTightening torque 4.43 lbf.in (0.5 N.m) Overvoltage category III EN/IEC 60664-1 Net Weight 0.88 lb(US) (0.4 kg) Immunity to microbreaks 1 ms Product Certifications GL
C-tick
CSA
UL
GOSTStandards EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-11
EN/IEC 61000-4-3
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-12
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-4 level 3IP degree of protection IP20 IEC 60529 terminal block)
IP40 IEC 60529 front panel)Environmental characteristic EMC directive EN/IEC 61000-6-2
EMC directive EN/IEC 61000-6-3
EMC directive EN/IEC 61000-6-4
EMC directive EN/IEC 61131-2 zone B
Low voltage directive EN/IEC 61131-2Disturbance radiated/conducted Class B EN 55022-11 group 1 Pollution degree 2 EN/IEC 61131-2 Ambient air temperature for operation -4…104 °F (-20…40 °C) in non-ventilated enclosure IEC 60068-2-1 and IEC 60068-2-2
-4…131 °F (-20…55 °C) IEC 60068-2-1 and IEC 60068-2-2Ambient Air Temperature for Storage -40…158 °F (-40…70 °C) Operating altitude 6561.68 ft (2000 m) Maximum altitude transport 10000.00 ft (3048 m) Relative Humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 2.68 in (6.8 cm) Package 1 Width 3.94 in (10.0 cm) Package 1 Length 5.31 in (13.5 cm) Package 1 Weight 13.44 oz (381.0 g) Unit Type of Package 2 S03 Number of Units in Package 2 20 Package 2 Height 11.81 in (30.0 cm) Package 2 Width 11.81 in (30.0 cm) Package 2 Length 15.75 in (40.0 cm) Package 2 Weight 17.84 lb(US) (8.094 kg)