SR3B261FU

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeModular smart relay
    local displayWith
    Number or control scheme lines0…500 with FBD programming
    0…240 with ladder programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage100…240 V
    Supply voltage limits85…264 V
    Supply frequency50/60 Hz
    Maximum supply current100 mA at 100 V (without extension)
    50 mA at 240 V (without extension)
    60 mA at 240 V (with extensions)
    80 mA at 100 V (with extensions)
    Power consumption in VA12 VA without extension
    17 VA with extensions
    Isolation voltage1780 V
    Protection typeAgainst inversion of terminals (control instructions not executed)
    Discrete input number16
    Discrete input voltage100…240 V AC
    Discrete input current0.6 mA
    Discrete input frequency47…53 Hz
    57…63 Hz
    Voltage state 1 guaranteed>= 79 V for discrete input
    Voltage state 0 guaranteed<= 40 V for discrete input
    Current state 1 guaranteed>= 0.17 mA (discrete input)
    Current state 0 guaranteed<= 0.5 mA (discrete input)
    Input impedance350 kOhm for discrete input
    Number of outputs10 relay
    Output voltage limits5…30 V DC (relay output)
    24…250 V AC
    Contacts type and compositionNO for relay output
    Output thermal current5 A for 2 outputs for relay output
    8 A for 8 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time50 ms with ladder programming (from state 0 to state 1) for discrete input
    50 ms with ladder programming (from state 1 to state 0) for discrete input
    50…255 ms with FBD programming (from state 0 to state 1) for discrete input
    50…255 ms with FBD programming (from state 1 to state 0) for discrete input
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.4 kg
    Immunity to microbreaks10 ms
    Product certificationsGOST
    GL
    CSA
    UL
    C-Tick
    StandardsEN/IEC 61000-4-12
    EN/IEC 60068-2-27 Ea
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-5
    EN/IEC 61000-4-11
    EN/IEC 61000-4-3
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-4 level 3
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.8 cm
    Package 1 Width13.5 cm
    Package 1 Length10.0 cm
    Package 1 Weight390.0 g
    Unit Type of Package 2S03
    Number of Units in Package 220
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight8.302 kg

SR3B261JD

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeModular smart relay
    local displayWith
    Number or control scheme lines0…500 with FBD programming
    0…240 with ladder programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage12 V
    Supply voltage limits10.4…14.4 V
    Maximum supply current250 mA (without extension)
    400 mA (with extensions)
    Power dissipation in W3 W without extension
    5 W with extensions
    Reverse polarity protectionWith
    Discrete input number16 conforming to EN/IEC 61131-2 type 1
    Discrete input typeResistive
    Discrete input voltage12 V DC
    Discrete input current4 mA
    Counting frequency1 kHz for discrete input
    Voltage state 1 guaranteed>= 7 V for IB…IG used as discrete input circuit
    >= 5.6 V for I1…IA and IH…IR discrete input circuit
    Voltage state 0 guaranteed<= 3 V for IB…IG used as discrete input circuit
    <= 2.4 V for I1…IA and IH…IR discrete input circuit
    Current state 1 guaranteed>= 2 mA (I1…IA and IH…IR discrete input circuit)
    >= 0.5 mA (IB…IG used as discrete input circuit)
    Current state 0 guaranteed<= 0.2 mA (IB…IG used as discrete input circuit)
    <= 0.9 mA (I1…IA and IH…IR discrete input circuit)
    Input compatibility3-wire proximity sensors PNP for discrete input
    Analogue input number6
    Analogue input typeCommon mode
    Analogue input range0…12 V
    0…10 V
    Maximum permissible voltage14.4 V for analogue input circuit
    Analogue input resolution8 bits at maximum voltage
    LSB value39 mV for analogue input circuit
    Conversion timeSmart relay cycle time for analogue input circuit
    Conversion error+/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
    Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    Input impedance14 kOhm for IB…IG used as analogue input circuit
    14 kOhm for IB…IG used as discrete input circuit
    2.7 kOhm for I1…IA and IH…IR discrete input circuit
    Number of outputs10 relay
    Output voltage limits24…250 V AC (relay output)
    5…30 V DC (relay output)
    Contacts type and compositionNO for relay output
    Output thermal current5 A for 2 outputs for relay output
    8 A for 8 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.4 kg
    Immunity to microbreaks1 ms repeated 20 times
    Product certificationsC-Tick
    UL
    CSA
    GL
    GOST
    StandardsEN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-12
    EN/IEC 61000-4-3
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-5
    EN/IEC 61000-4-11
    EN/IEC 61000-4-2 level 3
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-4 level 3
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.8 cm
    Package 1 Width10 cm
    Package 1 Length13.3 cm
    Package 1 Weight383 g
    Unit Type of Package 2S03
    Number of Units in Package 220
    Package 2 Height30 cm
    Package 2 Width30 cm
    Package 2 Length40 cm
    Package 2 Weight8.056 kg

SR3B262BD

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeModular smart relay
    local displayWith
    Number or control scheme lines0…500 with FBD programming
    0…240 with ladder programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V
    Supply voltage limits19.2…30 V
    Maximum supply current180 mA (with extensions)
    70 mA (without extension)
    Power dissipation in W10 W with extensions
    5 W without extension
    Reverse polarity protectionWith
    Discrete input number16 conforming to EN/IEC 61131-2 type 1
    Discrete input typeResistive
    Discrete input voltage24 V DC
    Discrete input current4 mA
    Counting frequency1 kHz for discrete input
    Voltage state 1 guaranteed>= 15 V for I1…IA and IH…IR discrete input circuit
    >= 15 V for IB…IG used as discrete input circuit
    Voltage state 0 guaranteed<= 5 V for I1…IA and IH…IR discrete input circuit
    <= 5 V for IB…IG used as discrete input circuit
    Current state 1 guaranteed>= 1.2 mA (IB…IG used as discrete input circuit)
    >= 2.2 mA (I1…IA and IH…IR discrete input circuit)
    Current state 0 guaranteed<= 0.5 mA (IB…IG used as discrete input circuit)
    <= 0.75 mA (I1…IA and IH…IR discrete input circuit)
    Input compatibility3-wire proximity sensors PNP for discrete input
    Analogue input number6
    Analogue input typeCommon mode
    Analogue input range0…24 V
    0…10 V
    Temperature probe typeNTC 10k at 25 °C
    NTC 1000k at 25 °C
    KTY81 210/220/221/222/250
    Pt 500
    Maximum permissible voltage30 V for analogue input circuit
    Analogue input resolution8 bits
    LSB value39 mV for analogue input circuit
    Conversion timeSmart relay cycle time for analogue input circuit
    Conversion error+/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
    Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    Input impedance12 kOhm for IB…IG used as analogue input circuit
    12 kOhm for IB…IG used as discrete input circuit
    7.4 kOhm for I1…IA and IH…IR discrete input circuit
    Number of outputs10 transistor
    Output voltage24 V transistor output
    Output voltage limits19.2…30 V DC (transistor output)
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    Load current0.5…0.625 A transistor output
    [Ures] residual voltage2 V at state 1 transistor output
    Overload protectionWith overload protection for transistor output
    Short-circuit protectionWith transistor output
    Overvoltage protectionWith overvoltage protection for transistor output
    ClockWith
    Response time<= 1 ms (from state 0 to state 1) for transistor output
    <= 1 ms (from state 1 to state 0) for transistor output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.3 kg
    Immunity to microbreaks1 ms
    Product certificationsC-Tick
    GOST
    UL
    CSA
    GL
    StandardsEN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-5
    EN/IEC 61000-4-11
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-3
    EN/IEC 61000-4-2 level 3
    EN/IEC 60068-2-6 Fc
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.8 cm
    Package 1 Width10.0 cm
    Package 1 Length13.5 cm
    Package 1 Weight298.0 g
    Unit Type of Package 2S03
    Number of Units in Package 220
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight6.586 kg

SR3MBU01BD

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeModbus slave communication module
    wiring mode2 or 4 wires
    Product compatibilityAll modules with 24 V supply SR3 B…BD
    Communication port protocolModbus
    Communication port supportRS485
    Electrical connection1 connector RJ45
    Transmission frameRTU
    ASCII
    Transmission rate1200 bauds
    9600 bauds
    38400 bauds
    19200 bauds
    57600 bauds
    28800 bauds
    2400 bauds
    4800 bauds
    ParityNo
    Odd
    Even
    Number of addresses1…247
    Programming languageFBD
    Ladder
    Connections – terminalsScrew terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) semi-solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) solid
    Screw terminals, 2 x 0.25…2 x 1.5 mm² (AWG 23…AWG 16) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Local signalling1 LED for communication
    1 LED for power ON
    Net weight0.11 kg
    Product certificationsGOST
    CSA
    GL
    C-Tick
    UL
    StandardsEN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-3
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-5
    EN/IEC 60068-2-6 Fc
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.0 cm
    Package 1 Width6.5 cm
    Package 1 Length11.0 cm
    Package 1 Weight101.9 g
    Unit Type of Package 2S03
    Number of Units in Package 248
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight5.54 kg

SR3NET01BD

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeEthernet communication module
    Range of productZelio Logic
    Product or component typeEthernet communication module
    Complementary
    Product compatibilityAll modules with 24 V supply SR3 B…BD
    Communication port protocolEthernet
    Communication port support10/100BASE-T
    Electrical connection1 connector RJ45
    Programming languageFBD
    Connections – terminalsScrew terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) semi-solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) solid
    Screw terminals, 2 x 0.25…2 x 1.5 mm² (AWG 23…AWG 16) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Local signalling1 LED for communication (LK/ACT 10/100)
    1 LED for status (STS)
    Net weight0.11 kg
    Product certificationsCSA
    C-Tick
    GOST
    UL
    StandardsEN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-5
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-3
    EN/IEC 60068-2-6 Fc
    EN/IEC 60068-2-27 Ea
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.0 cm
    Package 1 Width6.5 cm
    Package 1 Length11.0 cm
    Package 1 Weight109.0 g
    Unit Type of Package 2S03
    Number of Units in Package 248
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight5.78 kg

SR3PACK2BD

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident

 

  • Range of productZelio Logic
    Product or component typeModular discovery packs
    Discrete input number16 conforming to EN/IEC 61131-2 type 1
    Number of outputs10 relay
    kit compositionCable PC SR2USB01 for connection to PC
    SR3B261BD
    Input/output number26
    local displayWith
    Number or control scheme lines120 with ladder programming
    0…200 with FBD programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V
    Supply voltage limits19.2…30 V
    Maximum supply current190 mA (without extension)
    300 mA (with extensions)
    Power dissipation in W10 W with extensions
    6 W without extension
    Reverse polarity protectionWith
    Discrete input typeResistive
    Discrete input voltage24 V DC
    Discrete input current4 mA
    Counting frequency1 kHz for discrete input
    Voltage state 1 guaranteed>= 15 V for I1…IA and IH…IR discrete input circuit
    >= 15 V for IB…IG used as discrete input circuit
    Voltage state 0 guaranteed<= 5 V for I1…IA and IH…IR discrete input circuit
    <= 5 V for IB…IG used as discrete input circuit
    Current state 1 guaranteed>= 1.2 mA (IB…IG used as discrete input circuit)
    >= 2.2 mA (I1…IA and IH…IR discrete input circuit)
    Current state 0 guaranteed<= 0.5 mA (IB…IG used as discrete input circuit)
    <= 0.75 mA (I1…IA and IH…IR discrete input circuit)
    Input compatibility3-wire proximity sensors PNP for discrete input
    Analogue input number6
    Analogue input typeCommon mode
    Analogue input range0…10 V
    0…24 V
    Temperature probe typeNTC 10k at 25 °C
    NTC 1000k at 25 °C
    KTY81 210/220/221/222/250
    Pt 500
    Maximum permissible voltage30 V for analogue input circuit
    Analogue input resolution8 bits
    LSB value39 mV for analogue input circuit
    Conversion timeSmart relay cycle time for analogue input circuit
    Conversion error+/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
    Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    Input impedance12 kOhm for IB…IG used as analogue input circuit
    12 kOhm for IB…IG used as discrete input circuit
    7.4 kOhm for I1…IA and IH…IR discrete input circuit
    Output voltage limits24…250 V AC (relay output)
    5…30 V DC (relay output)
    Contacts type and compositionNO for relay output
    Output thermal current5 A for 2 outputs for relay output
    8 A for 8 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.85 kg
    Immunity to microbreaks1 ms
    Product certificationsGOST
    GL
    UL
    CSA
    C-Tick
    StandardsEN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-12
    EN/IEC 60068-2-6 Fc
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-5
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-3
    EN/IEC 61000-4-11
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.2 cm
    Package 1 Width15.5 cm
    Package 1 Length23.5 cm
    Package 1 Weight523.0 g
    Unit Type of Package 2S03
    Number of Units in Package 210
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight5.714 kg

SR3PACK2FU

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident

 

  • Range of productZelio Logic
    Product or component typeModular discovery packs
    Discrete input number16
    Number of outputs10 relay
    kit compositionCable PC SR2USB01 for connection to PC
    SR3B261FU
    Input/output number26
    local displayWith
    Number or control scheme lines120 with ladder programming
    0…200 with FBD programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage100…240 V
    Supply voltage limits85…264 V
    Supply frequency50/60 Hz
    Maximum supply current100 mA at 100 V (without extension)
    50 mA at 240 V (without extension)
    60 mA at 240 V (with extensions)
    80 mA at 100 V (with extensions)
    Power consumption in VA12 VA without extension
    17 VA with extensions
    Isolation voltage1780 V
    Protection typeAgainst inversion of terminals (control instructions not executed)
    Discrete input voltage100…240 V AC
    Discrete input current0.6 mA
    Discrete input frequency47…53 Hz
    57…63 Hz
    Voltage state 1 guaranteed>= 79 V for discrete input
    Voltage state 0 guaranteed<= 40 V for discrete input
    Current state 1 guaranteed>= 0.17 mA (discrete input)
    Current state 0 guaranteed<= 0.5 mA (discrete input)
    Input impedance350 kOhm for discrete input
    Output voltage limits5…30 V DC (relay output)
    24…250 V AC
    Contacts type and compositionNO for relay output
    Output thermal current5 A for 2 outputs for relay output
    8 A for 8 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time50 ms with ladder programming (from state 0 to state 1) for discrete input
    50 ms with ladder programming (from state 1 to state 0) for discrete input
    50…255 ms with FBD programming (from state 0 to state 1) for discrete input
    50…255 ms with FBD programming (from state 1 to state 0) for discrete input
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.85 kg
    Immunity to microbreaks10 ms
    Product certificationsGL
    UL
    C-Tick
    CSA
    GOST
    StandardsEN/IEC 61000-4-5
    EN/IEC 61000-4-2 level 3
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-3
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-11
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-12
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.3 cm
    Package 1 Width15.5 cm
    Package 1 Length23.5 cm
    Package 1 Weight532.0 g
    Unit Type of Package 2S03
    Number of Units in Package 210
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight5.817 kg

SR3PACKBD

  • Reverse polarity protection
  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • CSA, C-Tick, GOST, GL and UL certified

 

  • Range of productZelio Logic
    Product or component typeModular discovery packs
    Discrete input number6 conforming to EN/IEC 61131-2 type 1
    Number of outputs4 relay
    kit compositionSR3B101BD
    Cable PC SR2USB01 for connection to PC
    Input/output number10
    local displayWith
    Number or control scheme lines120 with ladder programming
    0…200 with FBD programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V
    Supply voltage limits19.2…30 V
    Maximum supply current100 mA (with extensions)
    100 mA (without extension)
    Power dissipation in W3 W without extension
    8 W with extensions
    Reverse polarity protectionWith
    Discrete input typeResistive
    Discrete input voltage24 V DC
    Discrete input current4 mA
    Counting frequency1 kHz for discrete input
    Voltage state 1 guaranteed>= 15 V for I1…IA and IH…IR discrete input circuit
    >= 15 V for IB…IG used as discrete input circuit
    Voltage state 0 guaranteed<= 5 V for I1…IA and IH…IR discrete input circuit
    <= 5 V for IB…IG used as discrete input circuit
    <= 5 V
    Current state 1 guaranteed>= 1.2 mA (IB…IG used as discrete input circuit)
    >= 2.2 mA (I1…IA and IH…IR discrete input circuit)
    Current state 0 guaranteed<= 0.5 mA (IB…IG used as discrete input circuit)
    <= 0.75 mA (I1…IA and IH…IR discrete input circuit)
    Input compatibility3-wire proximity sensors PNP for discrete input
    Analogue input number4
    Analogue input typeCommon mode
    Analogue input range0…24 V
    0…10 V
    Temperature probe typeNTC 10k at 25 °C
    NTC 1000k at 25 °C
    KTY81 210/220/221/222/250
    Pt 500
    Maximum permissible voltage30 V for analogue input circuit
    Analogue input resolution8 bits
    LSB value39 mV for analogue input circuit
    Conversion timeSmart relay cycle time for analogue input circuit
    Conversion error+/- 5 % at 25 °C for analogue input circuit
    +/- 6.2 % at 55 °C for analogue input circuit
    Repeat accuracy+/- 2 % at 55 °C for analogue input circuit
    Operating distance10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
    Input impedance12 kOhm for IB…IG used as analogue input circuit
    12 kOhm for IB…IG used as discrete input circuit
    7.4 kOhm for I1…IA and IH…IR discrete input circuit
    Output voltage limits24…250 V AC (relay output)
    5…30 V DC (relay output)
    Contacts type and compositionNO for relay output
    Output thermal current8 A for all 4 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.7 kg
    Immunity to microbreaks1 ms
    Product certificationsGL
    UL
    CSA
    GOST
    C-Tick
    StandardsEN/IEC 60068-2-27 Ea
    EN/IEC 60068-2-6 Fc
    EN/IEC 61000-4-3
    EN/IEC 61000-4-6 level 3
    EN/IEC 61000-4-11
    EN/IEC 61000-4-5
    EN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-4 level 3
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.2 cm
    Package 1 Width15.5 cm
    Package 1 Length23.3 cm
    Package 1 Weight390 g
    Unit Type of Package 2S03
    Number of Units in Package 210
    Package 2 Height30 cm
    Package 2 Width30 cm
    Package 2 Length40 cm
    Package 2 Weight4.409 kg

SR3PACKFU

  • It offers about 5,00,000 cycles of electrical durability
  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • Wide range of operating temperature from -20°C to 55°C

 

  • Range of productZelio Logic
    Product or component typeModular discovery packs
    Discrete input number6
    Number of outputs4 relay
    kit compositionSR3B101FU
    Cable PC SR2USB01 for connection to PC
    Input/output number10
    local displayWith
    Number or control scheme lines120 with ladder programming
    0…200 with FBD programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    6 s/month at 25 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage100…240 V
    Supply voltage limits85…264 V
    Supply frequency50/60 Hz
    Maximum supply current30 mA at 240 V (without extension)
    40 mA at 240 V (with extensions)
    80 mA at 100 V (with extensions)
    80 mA at 100 V (without extension)
    Power consumption in VA12 VA with extensions
    7 VA without extension
    Isolation voltage1780 V
    Protection typeAgainst inversion of terminals (control instructions not executed)
    Discrete input voltage100…240 V AC
    Discrete input current0.6 mA
    Discrete input frequency47…53 Hz
    57…63 Hz
    Voltage state 1 guaranteed>= 79 V for discrete input
    Voltage state 0 guaranteed<= 40 V for discrete input
    Current state 1 guaranteed>= 0.17 mA (discrete input)
    Current state 0 guaranteed<= 0.5 mA (discrete input)
    Input impedance350 kOhm for discrete input
    Output voltage limits5…30 V DC (relay output)
    24…250 V AC
    Contacts type and compositionNO for relay output
    Output thermal current8 A for all 4 outputs for relay output
    Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    ClockWith
    Response time50 ms with ladder programming (from state 0 to state 1) for discrete input
    50 ms with ladder programming (from state 1 to state 0) for discrete input
    50…255 ms with FBD programming (from state 0 to state 1) for discrete input
    50…255 ms with FBD programming (from state 1 to state 0) for discrete input
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.7 kg
    Immunity to microbreaks10 ms
    Product certificationsGOST
    C-Tick
    GL
    CSA
    UL
    StandardsEN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-4 level 3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-5
    EN/IEC 61000-4-11
    EN/IEC 61000-4-3
    EN/IEC 61000-4-6 level 3
    EN/IEC 60068-2-6 Fc
    EN/IEC 60068-2-27 Ea
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height7.0 cm
    Package 1 Width16.0 cm
    Package 1 Length24.0 cm
    Package 1 Weight485.0 g
    Unit Type of Package 2S03
    Number of Units in Package 210
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight5.326 kg

SR3XT101B

  • Reverse polarity protection
  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • More I/O than SR2 model, for larger applications

 

  • Range of productZelio Logic
    Product or component typeDiscrete I/O extension module
    Number or control scheme lines120 with ladder programming
    Cycle time6…90 ms
    Backup time10 years at 25 °C
    Clock drift12 min/year at 0…55 °C
    ChecksProgram memory on each power up
    [Us] rated supply voltage24 V AC
    Supply voltage limits20.4…28.8 V
    Supply frequency50/60 Hz
    Reverse polarity protectionWith
    Discrete input number6
    Discrete input voltage24 V AC
    Discrete input current4.4 mA
    Discrete input frequency47…53 Hz
    57…63 Hz
    Voltage state 1 guaranteed>= 14 V for discrete input
    Voltage state 0 guaranteed<= 5 V for discrete input
    Current state 1 guaranteed>= 2 mA (discrete input)
    Current state 0 guaranteed<= 0.5 mA (discrete input)
    Input impedance4.6 kOhm for discrete input
    Number of outputs4 relay
    Output voltage limits5…30 V DC (relay output)
    24…250 V AC
    Contacts type and compositionNO for relay output
    Output thermal current8 A for all 4 outputs for relay output
    Electrical durabilityAC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
    AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
    DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
    Switching capacity in mA>= 10 mA at 12 V (relay output)
    Operating rate in Hz0.1 Hz (at Ie) for relay output
    10 Hz (no load) for relay output
    Mechanical durability10000000 cycles for relay output
    [Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
    Response time50 ms with ladder programming (from state 0 to state 1) for discrete input
    50 ms with ladder programming (from state 1 to state 0) for discrete input
    50…255 ms with FBD programming (from state 0 to state 1) for discrete input
    50…255 ms with FBD programming (from state 1 to state 0) for discrete input
    10 ms (from state 0 to state 1) for relay output
    5 ms (from state 1 to state 0) for relay output
    Connections – terminalsScrew terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
    Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
    Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
    Tightening torque0.5 N.m
    Overvoltage categoryIII conforming to EN/IEC 60664-1
    Net weight0.2 kg
    Product certificationsGOST
    GL
    C-Tick
    CSA
    UL
    StandardsEN/IEC 61000-4-2 level 3
    EN/IEC 61000-4-5
    EN/IEC 61000-4-6 level 3
    EN/IEC 60068-2-6 Fc
    EN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-11
    EN/IEC 61000-4-3
    EN/IEC 61000-4-12
    EN/IEC 61000-4-4 level 3
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity95 % without condensation or dripping water
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6.8 cm
    Package 1 Width9.0 cm
    Package 1 Length10.0 cm
    Package 1 Weight178.0 g
    Unit Type of Package 2S03
    Number of Units in Package 230
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight5.988 kg

SR3XT101BD

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

SR3XT101FU

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm