مینی پی ال سی زلیو اشنایدر

فیلترها

دسته‌بندی را انتخاب کنید

SR2D201BD

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident

SR2D201FU

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

SR2E121B

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident

SR2E121BD

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident

SR2E121FU

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident

SR2E201B

  • Extreme compactness
  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
  • Flexible

SR2E201FU

  • Simple ladder programming, adapted for non-specialists
  • Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
  • Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident

 

Range of productZelio Logic
Product or component typeCompact smart relay
local displayWithout
Number or control scheme lines0…240 with ladder programming
0…500 with FBD programming
Cycle time6…90 ms
Backup time10 years at 25 °C
Clock drift12 min/year at 0…55 °C
6 s/month at 25 °C
ChecksProgram memory on each power up
[Us] rated supply voltage100…240 V AC
Supply voltage limits85…264 V
Supply frequency50/60 Hz
Maximum supply current100 mA at 100 V (without extension)
50 mA at 240 V (without extension)
Power consumption in VA11 VA without extension
Isolation voltage1780 V
Protection typeAgainst inversion of terminals (control instructions not executed)
Discrete input number12
Discrete input voltage100…240 V AC
Discrete input current0.6 mA
Discrete input frequency57…63 Hz
47…53 Hz
Voltage state 1 guaranteed>= 79 V for discrete input
Voltage state 0 guaranteed<= 40 V for discrete input
Current state 1 guaranteed>= 0.17 mA (discrete input)
Current state 0 guaranteed<= 0.5 mA (discrete input)
Analogue input number0
Input impedance350 kOhm for discrete input
Number of outputs8 relay
Output voltage limits5…30 V DC (relay output)
24…250 V AC
Contacts type and compositionNO for relay output
Output thermal current8 A for all 8 outputs for relay output
Electrical durabilityAC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
Switching capacity in mA>= 10 mA at 12 V (relay output)
Operating rate in Hz0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay output
Mechanical durability10000000 cycles for relay output
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
ClockWith
Response time50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50…255 ms with FBD programming (from state 0 to state 1) for discrete input
50…255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay output
Connections – terminalsScrew terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
Tightening torque0.5 N.m
Overvoltage categoryIII conforming to EN/IEC 60664-1
Net weight0.35 kg
Immunity to microbreaks10 ms
Product certificationsGL
GOST
CSA
UL
C-Tick
StandardsEN/IEC 61000-4-3
EN/IEC 61000-4-11
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-12
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-5
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-6 level 3
IP degree of protectionIP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529
Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2
Disturbance radiated/conductedClass B conforming to EN 55022-11 group 1
Pollution degree2 conforming to EN/IEC 61131-2
Ambient air temperature for operation-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
Ambient air temperature for storage-40…70 °C
Operating altitude2000 m
Maximum altitude transport3048 m
Relative humidity95 % without condensation or dripping water
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.5 cm
Package 1 Width13.3 cm
Package 1 Length9.9 cm
Package 1 Weight332.0 g
Unit Type of Package 2S03
Number of Units in Package 220
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight7.14 kg

SR2MAN01DE

Range of productZelio Logic
Document purposeProgramming on the smart relay
Document typeUser manual
FormatPaper A5 bound
languageGerman
Net weight0.303 kg
Warranty18 months

SR2MEM01

Main
Range of productZelio Logic
Accessory / separate part designationEEPROM memory cartridge
Accessory / separate part typeMemory cartridge
accessory / separate part categorySeparate parts
Accessory / separate part destination
Complementary
Net weight0.01 kg
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height1.5 cm
Package 1 Width2.5 cm
Package 1 Length4.5 cm
Package 1 Weight6 g
Unit Type of Package 2S01

SR2MEM02

  • Load the program functions developed with the software on smart relay
  • Transfer the program and corresponding firmware from PC to the smart relay
  • Compare the Smart relay data with the program, for firmware version byond version 3.0
  • The transfer of data is secured with a password request

 

Range of productPhaseo
Zelio Logic
Accessory / separate part designationEEPROM memory cartridge
Accessory / separate part typeMemory cartridge
accessory / separate part categorySeparate parts
Accessory / separate part destinationFor firmware version >= 3.0
Net weight0.01 kg
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height1.5 cm
Package 1 Width3 cm
Package 1 Length4.5 cm
Package 1 Weight6 g
Unit Type of Package 2S01
Number of Units in Package 270
Package 2 Height15 cm
Package 2 Width15 cm
Package 2 Length40 cm
Package 2 Weight599 g

SR2MOD01

  • Range of productModicon M251
    Modicon M221
    Zelio Logic
    Modicon M241
    Product or component typeAnalogue PSTN modem
    type of modemSIXNET VT-MODEM-5-WW
    Data backed upFlash memory
    kit compositionAnalogue PSTN modem
    1 telephone cable
    Function availableTransfer program
    Update firmware monitoring
    Send alarm/receive instruction
    Send alarm to e-mail address
    Number of messages28
    Electrical data recordingTelephone/e-mail
    Discrete and digital value
    Date and time
    [Us] rated supply voltage12…24 V DC
    Supply voltage limits10…30 V
    Maximum supply current140 mA at 12 V
    70 mA at 24 V
    9600 mA
    Power dissipation in W1.7 W
    Electrical connection1 cable Com-M specific to Zelio RS232 serial, specific Zelio communication protocol for link with the modem, AT commands
    1 cable Com-Z specific to Zelio, specific Zelio communication protocol for Zelio Logic smart relays SR.B….. and SR2 E….. Version (>= V3.1)
    Telephone cable
    Cable length2 m
    Insulation1780 V optocoupler, connector type: Com-Z specific to Zelio
    By the cable SR2 CBL07, connector type: Com-M specific to Zelio
    Connections – terminalsScrew terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) semi-solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) solid
    Screw terminals, 2 x 0.25…2 x 1.5 mm² (AWG 23…AWG 16) solid
    Tightening torque0.5 N.m
    Net weight0.265 kg
    Product certificationsFCC part 15 standard
    C-Tick
    ACA TS
    CTR21
    GOST
    UL
    AS/NZS
    CSA
    StandardsEN/IEC 60068-2-27 Ea
    EN/IEC 61000-4-5
    EN/IEC 60068-2-6 Fc
    Electromagnetic compatibilityConducted and radiated emissions class B group 1 conforming to EN 55022-11
    IP degree of protectionIP20 (terminal block) conforming to IEC 60529
    IP40 (front panel) conforming to IEC 60529
    Environmental characteristicEMC directive conforming to EN/IEC 61000-6-2
    EMC directive conforming to EN/IEC 61000-6-3
    EMC directive conforming to EN/IEC 61000-6-4
    EMC directive conforming to EN/IEC 61131-2 zone B
    Low voltage directive conforming to EN/IEC 61131-2
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-30…70 °C
    Ambient air temperature for storage-40…85 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity5…95 % without condensation
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Height6 cm
    Package 1 Width14.5 cm
    Package 1 Length15.3 cm
    Package 1 Weight262 g

SR2MOD02

  • Range of productZelio Logic
    Product or component typeGSM modem
    type of modemType quad band 900/1800 MHz, 850/1900 MHz
    Data backed upFlash memory
    kit compositionGSM modem
    Fixing on DIN rail (assembled with the GSM modem)
    1 supply cable
    1 antenna with cable
    2 lugs for plate mounting
    Function availableSend alarm/receive instruction
    Send alarm to e-mail address
    Transfer program
    Update firmware monitoring
    Number of messages28
    Electrical data recordingTelephone/e-mail
    Discrete and digital value
    Date and time
    [Us] rated supply voltage12…24 V DC
    Supply voltage limits5.5…32 V
    Maximum supply current165 mA at 12 V
    87 A at 24 V
    2100 mA at 5.5 V
    Power dissipation in W2.1 W
    Associated fuse rating2.5 A
    Electrical connection1 cable Com-M Com-M specific to Zelio RS232 serial, specific Zelio communication protocol for link with the modem, AT commands
    1 antenna with cable
    1 cable
    1 cable Com-Z Com-Z specific to Zelio, specific Zelio communication protocol for Zelio Logic smart relays SR.B….. and SR2 E….. Version (>= V3.1)
    Supply cable
    Cable length1.5 m supply cable
    2.5 m antenna with cable
    Insulation1780 V optocoupler, connector type: Com-Z specific to Zelio
    By the cable SR2 CBL07, connector type: Com-M specific to Zelio
    Connections – terminalsScrew terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
    Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) semi-solid
    Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) solid
    Screw terminals, 2 x 0.25…2 x 1.5 mm² (AWG 23…AWG 16) solid
    Tightening torque0.5 N.m
    Net weight0.335 kg
    Product certificationsUL
    PTCRB
    GOST
    CSA
    IC
    FCC part 15 standard
    C-Tick
    StandardsEN/IEC 60068-2-6 Fc
    EN/IEC 60068-2-32
    Electromagnetic compatibilityConducted and radiated emissions class B group 1 conforming to EN 55022-11
    IP degree of protectionIP31 conforming to IEC 60529
    Environmental characteristicLow voltage directive conforming to EN/IEC 60950-1
    R and TTE directive conforming to ETSI EN 301419-1
    R and TTE directive conforming to ETSI EN 301 489-7
    R and TTE directive conforming to ETSI EN 301 511
    EMC directive conforming to ETSI EN 301 489-1
    Pollution degree2 conforming to EN/IEC 61131-2
    Ambient air temperature for operation-20…55 °C conforming to IEC 60068-2-2
    -20…55 °C conforming to IEC 60068-2-2
    Ambient air temperature for storage-40…70 °C
    Operating altitude2000 m
    Maximum altitude transport3048 m
    Relative humidity0…95 % at 55 °C without condensation
    0…95 % without condensation, during storage
    Unit Type of Package 1Db
    Number of Units in Package 11
    Package 1 Height7.5 cm
    Package 1 Width7.5 cm
    Package 1 Length14.7 cm
    Package 1 Weight318.0 g
    Unit Type of Package 2Doboz
    Number of Units in Package 220
    Package 2 Height30.0 cm
    Package 2 Width30.0 cm
    Package 2 Length40.0 cm
    Package 2 Weight6.895 kg
فروشگاه
مقايسه
حساب من