LR9D5367
range TeSys product name TeSys LRD
TeSys Decaproduct or component type Electronic thermal overload relay device short name LR9D relay application Motor protection product compatibility LC1D115
LC1D150
NSX circuit breakernetwork type AC thermal overload class Class 10 conforming to IEC 60947-4-1 signalling function Alarm thermal protection adjustment range 60…100 A [Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to ULnetwork frequency 50…60 Hz [Us] rated supply voltage 24 V DC supply voltage limits 17…32 V mounting support Under contactor
Railtripping threshold 1.05 +/- 0.06 In alarm conforming to IEC 60947-4-1
1.12 +/- 0.06 In de-energisation conforming to IEC 60947-4-1auxiliary contact composition 1 NO + 1 NC [Ith] conventional free air thermal current 5 A for signalling circuit [Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1 associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1 phase failure sensitivity Tripping in 4 s +/- 20 % conforming to IEC 60947-4-1 control type Red push-button: stop
Blue push-button: resettemperature compensation -20…60 °C switching capacity in mA 0…150 mA maximum voltage drop <2.5 V closed state connections – terminals Power circuit: bars
Control circuit: screw clamp terminals 1 cable(s) 0.5…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 0.5…1.5 mm² flexible without cable end
Alarm circuit: screw clamp terminals 1 cable(s) 0.5…1.5 mm² flexible without cable endtightening torque Alarm circuit: 0.45 N.m – on screw clamp terminals
Power circuit: 18 N.m – on bars M8
Control circuit: 1.2 N.m – on screw clamp terminalsheight 118 mm width 115 mm depth 125 mm net weight 0.885 kg protective treatment TH conforming to IEC 60068 IP degree of protection IP20 conforming to IEC 60529 ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1 ambient air temperature for storage -60…70 °C operating altitude <= 2000 m without derating mechanical robustness Vibrations: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Shocks: 13 Gn for 11 ms conforming to IEC 60068-2-7dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1 standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5product certifications UL
CSA
CCC
UKCAUnit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 922 g Package 1 Height 13 cm Package 1 width 15 cm Package 1 Length 16 cm Unit Type of Package 2 S04 Number of Units in Package 2 12 Package 2 Weight 11.91 kg Package 2 Height 30 cm Package 2 width 40 cm Package 2 Length 60 cm
LR9D5369
range TeSys product name TeSys LRD
TeSys Decaproduct or component type Electronic thermal overload relay device short name LR9D relay application Motor protection product compatibility NSX circuit breaker
LC1D150
LC1D115network type AC thermal overload class Class 10 conforming to IEC 60947-4-1 signalling function Alarm thermal protection adjustment range 90…150 A [Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to ULnetwork frequency 50…60 Hz [Us] rated supply voltage 24 V DC supply voltage limits 17…32 V mounting support Under contactor
Railtripping threshold 1.05 +/- 0.06 In alarm conforming to IEC 60947-4-1
1.12 +/- 0.06 In de-energisation conforming to IEC 60947-4-1auxiliary contact composition 1 NO + 1 NC [Ith] conventional free air thermal current 5 A for signalling circuit [Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1 associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1 phase failure sensitivity Tripping in 4 s +/- 20 % conforming to IEC 60947-4-1 control type Red push-button: stop
Blue push-button: resettemperature compensation -20…60 °C switching capacity in mA 0…150 mA maximum voltage drop <2.5 V closed state connections – terminals Power circuit: bars
Control circuit: screw clamp terminals 1 cable(s) 0.5…1.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 0.5…1.5 mm² flexible without cable end
Alarm circuit: screw clamp terminals 1 cable(s) 0.5…1.5 mm² flexible without cable endtightening torque Alarm circuit: 0.45 N.m – on screw clamp terminals
Power circuit: 18 N.m – on bars M8
Control circuit: 1.2 N.m – on screw clamp terminalsheight 118 mm width 115 mm depth 125 mm net weight 0.885 kg climatic withstand Conforming to IACS E10 IP degree of protection IP20 conforming to IEC 60529 ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1 ambient air temperature for storage -60…70 °C operating altitude <= 2000 m without derating mechanical robustness Vibrations: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6
Shocks: 13 Gn for 11 ms conforming to IEC 60068-2-7dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1 standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5product certifications UL
CSA
CCC
UKCAUnit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 924.0 g Package 1 Height 15.0 cm Package 1 width 16.0 cm Package 1 Length 13.0 cm Unit Type of Package 2 S04 Number of Units in Package 2 12 Package 2 Weight 11.88 kg Package 2 Height 30.0 cm Package 2 width 40.0 cm Package 2 Length 60.0 cm Unit Type of Package 3 P06 Number of Units in Package 3 48 Package 3 Weight 56.804 kg Package 3 Height 77.0 cm Package 3 width 80.0 cm Package 3 Length 60.0 cm
LR9F5371
range TeSys product name TeSys LRF device short name LR9F product or component type Electronic thermal overload relay relay application Motor protection product compatibility LC1F185…LC1F265 network type AC thermal overload class Class 10 conforming to IEC 60947-4 thermal protection adjustment range 132…220 A network frequency 50/60 Hz mounting support Direct on contactor
Platetripping threshold 1.12 +/- 0.06 In tripping conforming to IEC 60947-4-1 surge withstand 4 kV conforming to IEC 61000-4-5 contacts type and composition 1 NO + 1 NC [Ith] conventional free air thermal current 5 A for control circuit [Ue] rated operational voltage 1000 V AC 50/60 Hz for power circuit conforming to VDE 0110 group C [Ui] rated insulation voltage Power circuit: 1000 V AC conforming to IEC 60947-4 [Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-1 phase failure sensitivity Tripping in 4 s +/- 20 % conforming to IEC 60947-4-1 reset Manual reset on front relay control type Dial white full-load current adjustment
Test button red
Push-button red reset
Push-button stoplocal signalling Trip indicator temperature compensation -20…70 °C current consumption <= 5 mA no-load switching capacity for alarm 0…150 mA maximum voltage drop <2.5 V closed state connections – terminals Control circuit: screw clamp terminals 1 cable 0.75…2.5 mm² – cable stiffness: flexible – with cable end
Control circuit: screw clamp terminals 1 cable 0.75…2.5 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 1 cable 0.75…4 mm² – cable stiffness: flexible – without cable end
Control circuit: screw clamp terminals 2 cable 1…1.5 mm² – cable stiffness: flexible – with cable end
Control circuit: screw clamp terminals 2 cable 1…2.5 mm² – cable stiffness: flexible – without cable end
Control circuit: screw clamp terminals 2 cable 1 mm² – cable stiffness: solid
Power circuit: lugs-ring terminals M10tightening torque Control circuit: 1.2 N.m on screw clamp terminals
Power circuit: 35 N.m on screw clamp terminalsheight 101 mm width 115 mm depth 123.5 mm net weight 0.95 kg standards IEC 60255-17
IEC 60947-4-1
IEC 60255-8
VDE 0660
EN 60947-4-1product certifications UL
CSA
UKCAprotective treatment TH IP degree of protection IP20 conforming to IEC 60529
IP20 conforming to VDE 0106ambient air temperature for operation -20…55 °C conforming to IEC 60255-8 ambient air temperature for storage -40…85 °C operating altitude <= 2000 m without derating fire resistance 850 °C conforming to IEC 60695-2-1 mechanical robustness Shocks: 13 Gn for 11 ms conforming to IEC 60068-2-7
Vibrations 5…300 Hz: 2 Gn conforming to IEC 60068-2-6dielectric strength 6 kV 50 Hz conforming to IEC 255-5 electromagnetic compatibility Resistance to electrostatic discharge: 6 kV in indirect mode conforming to IEC 61000-4-2
Resistance to electrostatic discharge: 8 kV in air conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test: 10 V/m conforming to IEC 61000-4-3
Fast transients immunity test: 2 kV conforming to IEC 61000-4-4Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 1.035 kg Package 1 Height 15.0 cm Package 1 width 16.5 cm Package 1 Length 13.0 cm Unit Type of Package 2 S04 Number of Units in Package 2 11 Package 2 Weight 12.03 kg Package 2 Height 30.0 cm Package 2 width 40.0 cm Package 2 Length 60.0 cm Unit Type of Package 3 P06 Number of Units in Package 3 44 Package 3 Weight 59.048 kg Package 3 Height 77.0 cm Package 3 width 60.0 cm Package 3 Length 80.0 cm
LRD03
range TeSys
TeSys Decaproduct name TeSys LRD
TeSys Decaproduct or component type Differential thermal overload relay device short name LRD relay application Motor protection product compatibility LC1D25
LC1D18
LC1D38
LC1D12
LC1D32
LC1D09network type AC
DCthermal overload class Class 10A conforming to IEC 60947-4-1 thermal protection adjustment range 0.25…0.4 A [Ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1network frequency 0…400 Hz mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactortripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 auxiliary contact composition 1 NO + 1 NC [Ith] conventional free air thermal current 5 A for signalling circuit permissible current 3 A at 120 V AC-15 for signalling circuit
0.22 A at 125 V DC-13 for signalling circuit[Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1 associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit[Uimp] rated impulse withstand voltage 6 kV phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0 control type Red push-button: stop
Blue push-button: resettemperature compensation -20…60 °C connections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable endtightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 1.7 N.m – on screw clamp terminalsheight 66 mm width 45 mm depth 70 mm net weight 0.124 kg protective treatment TH conforming to IEC 60068 IP degree of protection IP20 conforming to IEC 60529 ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1 ambient air temperature for storage -60…70 °C flame retardance V1 conforming to UL 94 mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1 standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495product certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCAUnit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 138 g Package 1 Height 5 cm Package 1 width 7.8 cm Package 1 Length 9 cm Unit Type of Package 2 S02 Number of Units in Package 2 24 Package 2 Weight 4 kg Package 2 Height 15 cm Package 2 width 30 cm Package 2 Length 40 cm Unit Type of Package 3 P06 Number of Units in Package 3 384 Package 3 Weight 67 kg Package 3 Height 80 cm Package 3 width 80 cm Package 3 Length 60 cm
LRD04
range TeSys
TeSys Decaproduct name TeSys LRD
TeSys Decaproduct or component type Differential thermal overload relay device short name LRD relay application Motor protection product compatibility LC1D25
LC1D38
LC1D32
LC1D18
LC1D12
LC1D09network type AC
DCthermal overload class Class 10A conforming to IEC 60947-4-1 thermal protection adjustment range 0.4…0.63 A [Ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1network frequency 0…400 Hz mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactortripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 auxiliary contact composition 1 NO + 1 NC [Ith] conventional free air thermal current 5 A for signalling circuit permissible current 3 A at 120 V AC-15 for signalling circuit
0.22 A at 125 V DC-13 for signalling circuit[Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1 associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit[Uimp] rated impulse withstand voltage 6 kV phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0 control type Red push-button: stop
Blue push-button: resettemperature compensation -20…60 °C connections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable endtightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 1.7 N.m – on screw clamp terminalsheight 66 mm width 45 mm depth 70 mm net weight 0.124 kg protective treatment TH conforming to IEC 60068 IP degree of protection IP20 conforming to IEC 60529 ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1 ambient air temperature for storage -60…70 °C flame retardance V1 conforming to UL 94 mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1 standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495product certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCAUnit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 137 g Package 1 Height 4.9 cm Package 1 width 7.7 cm Package 1 Length 8.8 cm Unit Type of Package 2 S02 Number of Units in Package 2 24 Package 2 Weight 3.62 kg Package 2 Height 15 cm Package 2 width 30 cm Package 2 Length 40 cm Unit Type of Package 3 P06 Number of Units in Package 3 384 Package 3 Weight 69.924 kg Package 3 Height 77 cm Package 3 width 60 cm Package 3 Length 80 cm
LRD05
range TeSys
TeSys Decaproduct name TeSys LRD
TeSys Decaproduct or component type Differential thermal overload relay device short name LRD relay application Motor protection product compatibility LC1D25
LC1D38
LC1D12
LC1D32
LC1D18
LC1D09network type AC
DCthermal overload class Class 10A conforming to IEC 60947-4-1 thermal protection adjustment range 0.63…1 A [Ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1network frequency 0…400 Hz mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactortripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 auxiliary contact composition 1 NO + 1 NC [Ith] conventional free air thermal current 5 A for signalling circuit permissible current 3 A at 120 V AC-15 for signalling circuit
0.22 A at 125 V DC-13 for signalling circuit[Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1 associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit[Uimp] rated impulse withstand voltage 6 kV phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0 control type Red push-button: stop
Blue push-button: resettemperature compensation -20…60 °C connections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable endtightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 1.7 N.m – on screw clamp terminalsheight 66 mm width 45 mm depth 70 mm net weight 0.124 kg protective treatment TH conforming to IEC 60068 IP degree of protection IP20 conforming to IEC 60529 ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1 ambient air temperature for storage -60…70 °C flame retardance V1 conforming to UL 94 mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1 standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495product certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCAUnit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 137 g Package 1 Height 4.9 cm Package 1 width 7.7 cm Package 1 Length 8.8 cm Unit Type of Package 2 S02 Number of Units in Package 2 24 Package 2 Weight 3.634 kg Package 2 Height 15 cm Package 2 width 30 cm Package 2 Length 40 cm Unit Type of Package 3 P06 Number of Units in Package 3 384 Package 3 Weight 68.388 kg Package 3 Height 80 cm Package 3 width 80 cm Package 3 Length 60 cm
LRD06
range TeSys
TeSys Decaproduct name TeSys LRD
TeSys Decaproduct or component type Differential thermal overload relay device short name LRD relay application Motor protection product compatibility LC1D25
LC1D32
LC1D12
LC1D18
LC1D38
LC1D09network type DC
ACthermal overload class Class 10A conforming to IEC 60947-4-1 thermal protection adjustment range 1…1.6 A [Ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1network frequency 0…400 Hz mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactortripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 auxiliary contact composition 1 NO + 1 NC [Ith] conventional free air thermal current 5 A for signalling circuit permissible current 3 A at 120 V AC-15 for signalling circuit
0.22 A at 125 V DC-13 for signalling circuit[Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1 associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit[Uimp] rated impulse withstand voltage 6 kV phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0 control type Red push-button: stop
Blue push-button: resettemperature compensation -20…60 °C connections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable endtightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 1.7 N.m – on screw clamp terminalsheight 66 mm width 45 mm depth 70 mm net weight 0.124 kg protective treatment TH conforming to IEC 60068 IP degree of protection IP20 conforming to IEC 60529 ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1 ambient air temperature for storage -60…70 °C flame retardance V1 conforming to UL 94 mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1 standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495product certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCAUnit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 141.9 g Package 1 Height 5.2 cm Package 1 width 7.8 cm Package 1 Length 8.8 cm Unit Type of Package 2 S02 Number of Units in Package 2 24 Package 2 Weight 3.649 kg Package 2 Height 15 cm Package 2 width 30 cm Package 2 Length 40 cm Unit Type of Package 3 P06 Number of Units in Package 3 384 Package 3 Weight 68.388 kg Package 3 Height 77 cm Package 3 width 60 cm Package 3 Length 80 cm
LRD07
range TeSys
TeSys Decaproduct name TeSys LRD
TeSys Decaproduct or component type Differential thermal overload relay device short name LRD relay application Motor protection product compatibility LC1D18
LC1D38
LC1D32
LC1D25
LC1D12
LC1D09network type DC
ACthermal overload class Class 10A conforming to IEC 60947-4-1 thermal protection adjustment range 1.6…2.5 A [Ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1network frequency 0…400 Hz mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactortripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 auxiliary contact composition 1 NO + 1 NC [Ith] conventional free air thermal current 5 A for signalling circuit permissible current 3 A at 120 V AC-15 for signalling circuit
0.22 A at 125 V DC-13 for signalling circuit[Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1 associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit[Uimp] rated impulse withstand voltage 6 kV phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0 control type Red push-button: stop
Blue push-button: resettemperature compensation -20…60 °C connections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable endtightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 1.7 N.m – on screw clamp terminalsheight 66 mm width 45 mm depth 70 mm net weight 0.124 kg protective treatment TH conforming to IEC 60068 IP degree of protection IP20 conforming to IEC 60529 ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1 ambient air temperature for storage -60…70 °C flame retardance V1 conforming to UL 94 mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1 standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495product certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCAUnit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 138 g Package 1 Height 4.9 cm Package 1 width 7.7 cm Package 1 Length 8.8 cm Unit Type of Package 2 S02 Number of Units in Package 2 24 Package 2 Weight 3.653 kg Package 2 Height 15 cm Package 2 width 30 cm Package 2 Length 40 cm Unit Type of Package 3 P06 Number of Units in Package 3 384 Package 3 Weight 72.827 kg Package 3 Height 77 cm Package 3 width 60 cm Package 3 Length 80 cm
LRD08
range TeSys
TeSys Decaproduct name TeSys LRD
TeSys Decaproduct or component type Differential thermal overload relay device short name LRD relay application Motor protection product compatibility LC1D12
LC1D09
LC1D25
LC1D38
LC1D32
LC1D18network type AC
DCthermal overload class Class 10A conforming to IEC 60947-4-1 thermal protection adjustment range 2.5…4 A [Ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1network frequency 0…400 Hz mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactortripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 auxiliary contact composition 1 NO + 1 NC [Ith] conventional free air thermal current 5 A for signalling circuit permissible current 3 A at 120 V AC-15 for signalling circuit
0.22 A at 125 V DC-13 for signalling circuit[Ue] rated operational voltage 690 V AC 0…400 Hz for power circuit conforming to IEC 60947-4-1 associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit[Uimp] rated impulse withstand voltage 6 kV phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0 control type Red push-button: stop
Blue push-button: resettemperature compensation -20…60 °C connections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² solid without cable endtightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 1.7 N.m – on screw clamp terminalsheight 66 mm width 45 mm depth 70 mm net weight 0.124 kg protective treatment TH conforming to IEC 60068 IP degree of protection IP20 conforming to IEC 60529 ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1 ambient air temperature for storage -60…70 °C flame retardance V1 conforming to UL 94 mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1 standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495product certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCAUnit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 140.9 g Package 1 Height 4.8 cm Package 1 width 7.8 cm Package 1 Length 8.9 cm Unit Type of Package 2 S02 Number of Units in Package 2 24 Package 2 Weight 3.72 kg Package 2 Height 15 cm Package 2 width 30 cm Package 2 Length 40 cm Unit Type of Package 3 P06 Number of Units in Package 3 384 Package 3 Weight 71.076 kg Package 3 Height 77 cm Package 3 width 60 cm Package 3 Length 80 cm