Range of product Zelio Logic Product or component type Modular smart relay local display With Number or control scheme lines 0…500 with FBD programming
0…240 with ladder programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 100…240 V Supply voltage limits 85…264 V Supply frequency 50/60 Hz Maximum supply current 100 mA at 100 V (without extension)
50 mA at 240 V (without extension)
60 mA at 240 V (with extensions)
80 mA at 100 V (with extensions)Power consumption in VA 12 VA without extension
17 VA with extensionsIsolation voltage 1780 V Protection type Against inversion of terminals (control instructions not executed) Discrete input number 16 Discrete input voltage 100…240 V AC Discrete input current 0.6 mA Discrete input frequency 47…53 Hz
57…63 HzVoltage state 1 guaranteed >= 79 V for discrete input Voltage state 0 guaranteed <= 40 V for discrete input Current state 1 guaranteed >= 0.17 mA (discrete input) Current state 0 guaranteed <= 0.5 mA (discrete input) Input impedance 350 kOhm for discrete input Number of outputs 10 relay Output voltage limits 5…30 V DC (relay output)
24…250 V ACContacts type and composition NO for relay output Output thermal current 5 A for 2 outputs for relay output
8 A for 8 outputs for relay outputElectrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50…255 ms with FBD programming (from state 0 to state 1) for discrete input
50…255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.4 kg Immunity to microbreaks 10 ms Product certifications GOST
GL
CSA
UL
C-TickStandards EN/IEC 61000-4-12
EN/IEC 60068-2-27 Ea
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-11
EN/IEC 61000-4-3
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-4 level 3IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.8 cm Package 1 Width 13.5 cm Package 1 Length 10.0 cm Package 1 Weight 390.0 g Unit Type of Package 2 S03 Number of Units in Package 2 20 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 8.302 kg
SR3B261JD
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- More I/O than SR2 model, for larger applications
-
Range of product Zelio Logic Product or component type Modular smart relay local display With Number or control scheme lines 0…500 with FBD programming
0…240 with ladder programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 12 V Supply voltage limits 10.4…14.4 V Maximum supply current 250 mA (without extension)
400 mA (with extensions)Power dissipation in W 3 W without extension
5 W with extensionsReverse polarity protection With Discrete input number 16 conforming to EN/IEC 61131-2 type 1 Discrete input type Resistive Discrete input voltage 12 V DC Discrete input current 4 mA Counting frequency 1 kHz for discrete input Voltage state 1 guaranteed >= 7 V for IB…IG used as discrete input circuit
>= 5.6 V for I1…IA and IH…IR discrete input circuitVoltage state 0 guaranteed <= 3 V for IB…IG used as discrete input circuit
<= 2.4 V for I1…IA and IH…IR discrete input circuitCurrent state 1 guaranteed >= 2 mA (I1…IA and IH…IR discrete input circuit)
>= 0.5 mA (IB…IG used as discrete input circuit)Current state 0 guaranteed <= 0.2 mA (IB…IG used as discrete input circuit)
<= 0.9 mA (I1…IA and IH…IR discrete input circuit)Input compatibility 3-wire proximity sensors PNP for discrete input Analogue input number 6 Analogue input type Common mode Analogue input range 0…12 V
0…10 VMaximum permissible voltage 14.4 V for analogue input circuit Analogue input resolution 8 bits at maximum voltage LSB value 39 mV for analogue input circuit Conversion time Smart relay cycle time for analogue input circuit Conversion error +/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuitRepeat accuracy +/- 2 % at 55 °C for analogue input circuit Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit Input impedance 14 kOhm for IB…IG used as analogue input circuit
14 kOhm for IB…IG used as discrete input circuit
2.7 kOhm for I1…IA and IH…IR discrete input circuitNumber of outputs 10 relay Output voltage limits 24…250 V AC (relay output)
5…30 V DC (relay output)Contacts type and composition NO for relay output Output thermal current 5 A for 2 outputs for relay output
8 A for 8 outputs for relay outputElectrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.4 kg Immunity to microbreaks 1 ms repeated 20 times Product certifications C-Tick
UL
CSA
GL
GOSTStandards EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-12
EN/IEC 61000-4-3
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-11
EN/IEC 61000-4-2 level 3
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-4 level 3IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.8 cm Package 1 Width 10 cm Package 1 Length 13.3 cm Package 1 Weight 383 g Unit Type of Package 2 S03 Number of Units in Package 2 20 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 8.056 kg
SR3B262BD
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- More I/O than SR2 model, for larger applications
-
Range of product Zelio Logic Product or component type Modular smart relay local display With Number or control scheme lines 0…500 with FBD programming
0…240 with ladder programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 24 V Supply voltage limits 19.2…30 V Maximum supply current 180 mA (with extensions)
70 mA (without extension)Power dissipation in W 10 W with extensions
5 W without extensionReverse polarity protection With Discrete input number 16 conforming to EN/IEC 61131-2 type 1 Discrete input type Resistive Discrete input voltage 24 V DC Discrete input current 4 mA Counting frequency 1 kHz for discrete input Voltage state 1 guaranteed >= 15 V for I1…IA and IH…IR discrete input circuit
>= 15 V for IB…IG used as discrete input circuitVoltage state 0 guaranteed <= 5 V for I1…IA and IH…IR discrete input circuit
<= 5 V for IB…IG used as discrete input circuitCurrent state 1 guaranteed >= 1.2 mA (IB…IG used as discrete input circuit)
>= 2.2 mA (I1…IA and IH…IR discrete input circuit)Current state 0 guaranteed <= 0.5 mA (IB…IG used as discrete input circuit)
<= 0.75 mA (I1…IA and IH…IR discrete input circuit)Input compatibility 3-wire proximity sensors PNP for discrete input Analogue input number 6 Analogue input type Common mode Analogue input range 0…24 V
0…10 VTemperature probe type NTC 10k at 25 °C
NTC 1000k at 25 °C
KTY81 210/220/221/222/250
Pt 500Maximum permissible voltage 30 V for analogue input circuit Analogue input resolution 8 bits LSB value 39 mV for analogue input circuit Conversion time Smart relay cycle time for analogue input circuit Conversion error +/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuitRepeat accuracy +/- 2 % at 55 °C for analogue input circuit Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit Input impedance 12 kOhm for IB…IG used as analogue input circuit
12 kOhm for IB…IG used as discrete input circuit
7.4 kOhm for I1…IA and IH…IR discrete input circuitNumber of outputs 10 transistor Output voltage 24 V transistor output Output voltage limits 19.2…30 V DC (transistor output) [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Load current 0.5…0.625 A transistor output [Ures] residual voltage 2 V at state 1 transistor output Overload protection With overload protection for transistor output Short-circuit protection With transistor output Overvoltage protection With overvoltage protection for transistor output Clock With Response time <= 1 ms (from state 0 to state 1) for transistor output
<= 1 ms (from state 1 to state 0) for transistor outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.3 kg Immunity to microbreaks 1 ms Product certifications C-Tick
GOST
UL
CSA
GLStandards EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-5
EN/IEC 61000-4-11
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-12
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-2 level 3
EN/IEC 60068-2-6 FcIP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.8 cm Package 1 Width 10.0 cm Package 1 Length 13.5 cm Package 1 Weight 298.0 g Unit Type of Package 2 S03 Number of Units in Package 2 20 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 6.586 kg
SR3MBU01BD
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- More I/O than SR2 model, for larger applications
-
Range of product Zelio Logic Product or component type Modbus slave communication module wiring mode 2 or 4 wires Product compatibility All modules with 24 V supply SR3 B…BD Communication port protocol Modbus Communication port support RS485 Electrical connection 1 connector RJ45 Transmission frame RTU
ASCIITransmission rate 1200 bauds
9600 bauds
38400 bauds
19200 bauds
57600 bauds
28800 bauds
2400 bauds
4800 baudsParity No
Odd
EvenNumber of addresses 1…247 Programming language FBD
LadderConnections – terminals Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) semi-solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) solid
Screw terminals, 2 x 0.25…2 x 1.5 mm² (AWG 23…AWG 16) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Local signalling 1 LED for communication
1 LED for power ONNet weight 0.11 kg Product certifications GOST
CSA
GL
C-Tick
ULStandards EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-3
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-5
EN/IEC 60068-2-6 FcIP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.0 cm Package 1 Width 6.5 cm Package 1 Length 11.0 cm Package 1 Weight 101.9 g Unit Type of Package 2 S03 Number of Units in Package 2 48 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 5.54 kg
SR3NET01BD
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- More I/O than SR2 model, for larger applications
-
Range of product Zelio Logic Product or component type Ethernet communication module Range of product Zelio Logic Product or component type Ethernet communication module Complementary Product compatibility All modules with 24 V supply SR3 B…BD Communication port protocol Ethernet Communication port support 10/100BASE-T Electrical connection 1 connector RJ45 Programming language FBD Connections – terminals Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) semi-solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) solid
Screw terminals, 2 x 0.25…2 x 1.5 mm² (AWG 23…AWG 16) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Local signalling 1 LED for communication (LK/ACT 10/100)
1 LED for status (STS)Net weight 0.11 kg Product certifications CSA
C-Tick
GOST
ULStandards EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-3
EN/IEC 60068-2-6 Fc
EN/IEC 60068-2-27 EaIP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.0 cm Package 1 Width 6.5 cm Package 1 Length 11.0 cm Package 1 Weight 109.0 g Unit Type of Package 2 S03 Number of Units in Package 2 48 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 5.78 kg
SR3PACK2BD
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
-
Range of product Zelio Logic Product or component type Modular discovery packs Discrete input number 16 conforming to EN/IEC 61131-2 type 1 Number of outputs 10 relay kit composition Cable PC SR2USB01 for connection to PC
SR3B261BDInput/output number 26 local display With Number or control scheme lines 120 with ladder programming
0…200 with FBD programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 24 V Supply voltage limits 19.2…30 V Maximum supply current 190 mA (without extension)
300 mA (with extensions)Power dissipation in W 10 W with extensions
6 W without extensionReverse polarity protection With Discrete input type Resistive Discrete input voltage 24 V DC Discrete input current 4 mA Counting frequency 1 kHz for discrete input Voltage state 1 guaranteed >= 15 V for I1…IA and IH…IR discrete input circuit
>= 15 V for IB…IG used as discrete input circuitVoltage state 0 guaranteed <= 5 V for I1…IA and IH…IR discrete input circuit
<= 5 V for IB…IG used as discrete input circuitCurrent state 1 guaranteed >= 1.2 mA (IB…IG used as discrete input circuit)
>= 2.2 mA (I1…IA and IH…IR discrete input circuit)Current state 0 guaranteed <= 0.5 mA (IB…IG used as discrete input circuit)
<= 0.75 mA (I1…IA and IH…IR discrete input circuit)Input compatibility 3-wire proximity sensors PNP for discrete input Analogue input number 6 Analogue input type Common mode Analogue input range 0…10 V
0…24 VTemperature probe type NTC 10k at 25 °C
NTC 1000k at 25 °C
KTY81 210/220/221/222/250
Pt 500Maximum permissible voltage 30 V for analogue input circuit Analogue input resolution 8 bits LSB value 39 mV for analogue input circuit Conversion time Smart relay cycle time for analogue input circuit Conversion error +/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuitRepeat accuracy +/- 2 % at 55 °C for analogue input circuit Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit Input impedance 12 kOhm for IB…IG used as analogue input circuit
12 kOhm for IB…IG used as discrete input circuit
7.4 kOhm for I1…IA and IH…IR discrete input circuitOutput voltage limits 24…250 V AC (relay output)
5…30 V DC (relay output)Contacts type and composition NO for relay output Output thermal current 5 A for 2 outputs for relay output
8 A for 8 outputs for relay outputElectrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.85 kg Immunity to microbreaks 1 ms Product certifications GOST
GL
UL
CSA
C-TickStandards EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-12
EN/IEC 60068-2-6 Fc
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-5
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-3
EN/IEC 61000-4-11IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.2 cm Package 1 Width 15.5 cm Package 1 Length 23.5 cm Package 1 Weight 523.0 g Unit Type of Package 2 S03 Number of Units in Package 2 10 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 5.714 kg
SR3PACK2FU
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
-
Range of product Zelio Logic Product or component type Modular discovery packs Discrete input number 16 Number of outputs 10 relay kit composition Cable PC SR2USB01 for connection to PC
SR3B261FUInput/output number 26 local display With Number or control scheme lines 120 with ladder programming
0…200 with FBD programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 100…240 V Supply voltage limits 85…264 V Supply frequency 50/60 Hz Maximum supply current 100 mA at 100 V (without extension)
50 mA at 240 V (without extension)
60 mA at 240 V (with extensions)
80 mA at 100 V (with extensions)Power consumption in VA 12 VA without extension
17 VA with extensionsIsolation voltage 1780 V Protection type Against inversion of terminals (control instructions not executed) Discrete input voltage 100…240 V AC Discrete input current 0.6 mA Discrete input frequency 47…53 Hz
57…63 HzVoltage state 1 guaranteed >= 79 V for discrete input Voltage state 0 guaranteed <= 40 V for discrete input Current state 1 guaranteed >= 0.17 mA (discrete input) Current state 0 guaranteed <= 0.5 mA (discrete input) Input impedance 350 kOhm for discrete input Output voltage limits 5…30 V DC (relay output)
24…250 V ACContacts type and composition NO for relay output Output thermal current 5 A for 2 outputs for relay output
8 A for 8 outputs for relay outputElectrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50…255 ms with FBD programming (from state 0 to state 1) for discrete input
50…255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.85 kg Immunity to microbreaks 10 ms Product certifications GL
UL
C-Tick
CSA
GOSTStandards EN/IEC 61000-4-5
EN/IEC 61000-4-2 level 3
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-3
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-11
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-12IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.3 cm Package 1 Width 15.5 cm Package 1 Length 23.5 cm Package 1 Weight 532.0 g Unit Type of Package 2 S03 Number of Units in Package 2 10 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 5.817 kg
SR3PACKBD
- Reverse polarity protection
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- CSA, C-Tick, GOST, GL and UL certified
-
Range of product Zelio Logic Product or component type Modular discovery packs Discrete input number 6 conforming to EN/IEC 61131-2 type 1 Number of outputs 4 relay kit composition SR3B101BD
Cable PC SR2USB01 for connection to PCInput/output number 10 local display With Number or control scheme lines 120 with ladder programming
0…200 with FBD programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 24 V Supply voltage limits 19.2…30 V Maximum supply current 100 mA (with extensions)
100 mA (without extension)Power dissipation in W 3 W without extension
8 W with extensionsReverse polarity protection With Discrete input type Resistive Discrete input voltage 24 V DC Discrete input current 4 mA Counting frequency 1 kHz for discrete input Voltage state 1 guaranteed >= 15 V for I1…IA and IH…IR discrete input circuit
>= 15 V for IB…IG used as discrete input circuitVoltage state 0 guaranteed <= 5 V for I1…IA and IH…IR discrete input circuit
<= 5 V for IB…IG used as discrete input circuit
<= 5 VCurrent state 1 guaranteed >= 1.2 mA (IB…IG used as discrete input circuit)
>= 2.2 mA (I1…IA and IH…IR discrete input circuit)Current state 0 guaranteed <= 0.5 mA (IB…IG used as discrete input circuit)
<= 0.75 mA (I1…IA and IH…IR discrete input circuit)Input compatibility 3-wire proximity sensors PNP for discrete input Analogue input number 4 Analogue input type Common mode Analogue input range 0…24 V
0…10 VTemperature probe type NTC 10k at 25 °C
NTC 1000k at 25 °C
KTY81 210/220/221/222/250
Pt 500Maximum permissible voltage 30 V for analogue input circuit Analogue input resolution 8 bits LSB value 39 mV for analogue input circuit Conversion time Smart relay cycle time for analogue input circuit Conversion error +/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuitRepeat accuracy +/- 2 % at 55 °C for analogue input circuit Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit Input impedance 12 kOhm for IB…IG used as analogue input circuit
12 kOhm for IB…IG used as discrete input circuit
7.4 kOhm for I1…IA and IH…IR discrete input circuitOutput voltage limits 24…250 V AC (relay output)
5…30 V DC (relay output)Contacts type and composition NO for relay output Output thermal current 8 A for all 4 outputs for relay output Electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.7 kg Immunity to microbreaks 1 ms Product certifications GL
UL
CSA
GOST
C-TickStandards EN/IEC 60068-2-27 Ea
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-3
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-11
EN/IEC 61000-4-5
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-12
EN/IEC 61000-4-4 level 3IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.2 cm Package 1 Width 15.5 cm Package 1 Length 23.3 cm Package 1 Weight 390 g Unit Type of Package 2 S03 Number of Units in Package 2 10 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 4.409 kg
SR3PACKFU
- It offers about 5,00,000 cycles of electrical durability
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- Wide range of operating temperature from -20°C to 55°C
-
Range of product Zelio Logic Product or component type Modular discovery packs Discrete input number 6 Number of outputs 4 relay kit composition SR3B101FU
Cable PC SR2USB01 for connection to PCInput/output number 10 local display With Number or control scheme lines 120 with ladder programming
0…200 with FBD programmingCycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C
6 s/month at 25 °CChecks Program memory on each power up [Us] rated supply voltage 100…240 V Supply voltage limits 85…264 V Supply frequency 50/60 Hz Maximum supply current 30 mA at 240 V (without extension)
40 mA at 240 V (with extensions)
80 mA at 100 V (with extensions)
80 mA at 100 V (without extension)Power consumption in VA 12 VA with extensions
7 VA without extensionIsolation voltage 1780 V Protection type Against inversion of terminals (control instructions not executed) Discrete input voltage 100…240 V AC Discrete input current 0.6 mA Discrete input frequency 47…53 Hz
57…63 HzVoltage state 1 guaranteed >= 79 V for discrete input Voltage state 0 guaranteed <= 40 V for discrete input Current state 1 guaranteed >= 0.17 mA (discrete input) Current state 0 guaranteed <= 0.5 mA (discrete input) Input impedance 350 kOhm for discrete input Output voltage limits 5…30 V DC (relay output)
24…250 V ACContacts type and composition NO for relay output Output thermal current 8 A for all 4 outputs for relay output Electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Clock With Response time 50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50…255 ms with FBD programming (from state 0 to state 1) for discrete input
50…255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solid
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable endTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.7 kg Immunity to microbreaks 10 ms Product certifications GOST
C-Tick
GL
CSA
ULStandards EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-12
EN/IEC 61000-4-5
EN/IEC 61000-4-11
EN/IEC 61000-4-3
EN/IEC 61000-4-6 level 3
EN/IEC 60068-2-6 Fc
EN/IEC 60068-2-27 EaIP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.0 cm Package 1 Width 16.0 cm Package 1 Length 24.0 cm Package 1 Weight 485.0 g Unit Type of Package 2 S03 Number of Units in Package 2 10 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 5.326 kg
SR3XT101B
- Reverse polarity protection
- Simple ladder programming, adapted for non-specialists
- Discovery package, coming with Zelio Soft programming software: the simplest way to learn and use this relay
- Built-in EEPROM flash memory for data backup up to 10 years: easy-to-recover after a power shortage or incident
- More I/O than SR2 model, for larger applications
-
Range of product Zelio Logic Product or component type Discrete I/O extension module Number or control scheme lines 120 with ladder programming Cycle time 6…90 ms Backup time 10 years at 25 °C Clock drift 12 min/year at 0…55 °C Checks Program memory on each power up [Us] rated supply voltage 24 V AC Supply voltage limits 20.4…28.8 V Supply frequency 50/60 Hz Reverse polarity protection With Discrete input number 6 Discrete input voltage 24 V AC Discrete input current 4.4 mA Discrete input frequency 47…53 Hz
57…63 HzVoltage state 1 guaranteed >= 14 V for discrete input Voltage state 0 guaranteed <= 5 V for discrete input Current state 1 guaranteed >= 2 mA (discrete input) Current state 0 guaranteed <= 0.5 mA (discrete input) Input impedance 4.6 kOhm for discrete input Number of outputs 4 relay Output voltage limits 5…30 V DC (relay output)
24…250 V ACContacts type and composition NO for relay output Output thermal current 8 A for all 4 outputs for relay output Electrical durability AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1Switching capacity in mA >= 10 mA at 12 V (relay output) Operating rate in Hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay outputMechanical durability 10000000 cycles for relay output [Uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1 Response time 50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50…255 ms with FBD programming (from state 0 to state 1) for discrete input
50…255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay outputConnections – terminals Screw terminals, 1 x 0.25…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end
Screw terminals, 2 x 0.25…2 x 0.75 mm² (AWG 24…AWG 18) flexible with cable end
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) semi-solid
Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 25…AWG 14) solid
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) solidTightening torque 0.5 N.m Overvoltage category III conforming to EN/IEC 60664-1 Net weight 0.2 kg Product certifications GOST
GL
C-Tick
CSA
ULStandards EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-5
EN/IEC 61000-4-6 level 3
EN/IEC 60068-2-6 Fc
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-11
EN/IEC 61000-4-3
EN/IEC 61000-4-12
EN/IEC 61000-4-4 level 3IP degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529Environmental characteristic EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1 Pollution degree 2 conforming to EN/IEC 61131-2 Ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2Ambient air temperature for storage -40…70 °C Operating altitude 2000 m Maximum altitude transport 3048 m Relative humidity 95 % without condensation or dripping water Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.8 cm Package 1 Width 9.0 cm Package 1 Length 10.0 cm Package 1 Weight 178.0 g Unit Type of Package 2 S03 Number of Units in Package 2 30 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 5.988 kg
SR3XT101BD
-
range of product Easy Altivar 610 product or component type Variable speed drive product specific application Fan, pump, compressor, conveyor device short name ATV610 variant Standard version product destination Asynchronous motors mounting mode Cabinet mount EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m IP degree of protection IP20 type of cooling Forced convection supply frequency 50…60 Hz +/-5 % network number of phases 3 phases [Us] rated supply voltage 380…460 V – 15…10 % motor power kW 110 kW for normal duty 90 kW for heavy duty motor power hp 150 hp for normal duty 125 hp for heavy duty line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty) prospective line Isc 50 kA apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty) continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty) asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard output frequency 0.0001…0.5 kHz nominal switching frequency 2.5 kHz switching frequency 1…8 kHz adjustable number of preset speeds 16 preset speeds communication port protocol Modbus serial option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card output voltage <= power supply voltage motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized braking to standstill By DC injection protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm² connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial physical interface 2-wire RS 485 for Modbus serial transmission frame RTU for Modbus serial transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial type of polarization No impedance for Modbus serial number of addresses 1…247 for Modbus serial method of access Slave supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage width 320 mm height 852 mm 1159 mm with IP21 conformity kit depth 390 mm net weight 82 kg analogue input number 3 analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor discrete input number 6 discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68 discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) analogue output number 2 analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output relay output number 3 relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC isolation Between power and control terminals insulation resistance > 1 MOhm 500 V DC for 1 minute to earth noise level 76 dB conforming to 86/188/EEC power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz operating position Vertical +/- 10 degree electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 pollution degree 2 conforming to EN/IEC 61800-5-1 vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27 relative humidity 5…95 % without condensation conforming to IEC 60068-2-3 ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor) operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3 marking CE Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 96.344 kg Package 1 Height 47 cm Package 1 width 67 cm Package 1 Length 103 cm
SR3XT101FU
-
range of product Easy Altivar 610 product or component type Variable speed drive product specific application Fan, pump, compressor, conveyor device short name ATV610 variant Standard version product destination Asynchronous motors mounting mode Cabinet mount EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m IP degree of protection IP20 type of cooling Forced convection supply frequency 50…60 Hz +/-5 % network number of phases 3 phases [Us] rated supply voltage 380…460 V – 15…10 % motor power kW 110 kW for normal duty 90 kW for heavy duty motor power hp 150 hp for normal duty 125 hp for heavy duty line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty) prospective line Isc 50 kA apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty) continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty) asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard output frequency 0.0001…0.5 kHz nominal switching frequency 2.5 kHz switching frequency 1…8 kHz adjustable number of preset speeds 16 preset speeds communication port protocol Modbus serial option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card output voltage <= power supply voltage motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized braking to standstill By DC injection protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm² connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial physical interface 2-wire RS 485 for Modbus serial transmission frame RTU for Modbus serial transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial type of polarization No impedance for Modbus serial number of addresses 1…247 for Modbus serial method of access Slave supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage width 320 mm height 852 mm 1159 mm with IP21 conformity kit depth 390 mm net weight 82 kg analogue input number 3 analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor discrete input number 6 discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68 discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) analogue output number 2 analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output relay output number 3 relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC isolation Between power and control terminals insulation resistance > 1 MOhm 500 V DC for 1 minute to earth noise level 76 dB conforming to 86/188/EEC power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz operating position Vertical +/- 10 degree electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 pollution degree 2 conforming to EN/IEC 61800-5-1 vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27 relative humidity 5…95 % without condensation conforming to IEC 60068-2-3 ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor) operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3 marking CE Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 96.344 kg Package 1 Height 47 cm Package 1 width 67 cm Package 1 Length 103 cm