A9R50425

RangeActi9
Product nameActi9 iID K
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID K
Poles description4P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Quality labelsVDE
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 500 A
Im 500 A
Rated conditional short-circuit currentGL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Contact position indicatorNo
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches8
Height85 mm
Width72 mm
Depth69 mm
Net weight0.37 kg
ColourWhite
Mechanical durability5000 cycles
Electrical durabilityAC-1: 2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Electromagnetic compatibility8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.5 cm
Package 1 Width8.5 cm
Package 1 Length10 cm
Package 1 Weight357 g
Unit Type of Package 2S03
Number of Units in Package 227
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight10.257 kg
Unit Type of Package 3P12
Number of Units in Package 3216
Package 3 Height50 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight93.008 kg

A9R50440

RangeActi9
Product nameActi9 iID K
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID K
Poles description4P
Neutral positionLeft
[In] rated current40 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Quality labelsVDE
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 500 A
Im 500 A
Rated conditional short-circuit currentGL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Contact position indicatorNo
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches8
Height85 mm
Width72 mm
Depth69 mm
Net weight0.37 kg
ColourWhite
Mechanical durability5000 cycles
Electrical durabilityAC-1: 2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Electromagnetic compatibility8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8 cm
Package 1 Width7.5 cm
Package 1 Length10 cm
Package 1 Weight351 g
Unit Type of Package 2S03
Number of Units in Package 227
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight10.993 kg
Unit Type of Package 3P12
Number of Units in Package 3216
Package 3 Height75 cm
Package 3 Width60 cm
Package 3 Length80 cm
Package 3 Weight95.944 kg

A9R75225

RangeActi9
Product nameActi9 iID K
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID K
Poles description2P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Quality labelsVDE
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 500 A
Im 500 A
Rated conditional short-circuit currentGL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Contact position indicatorNo
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height85 mm
Width36 mm
Depth69 mm
Net weight0.21 kg
ColourWhite
Mechanical durability5000 cycles
Electrical durabilityAC-1: 2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Electromagnetic compatibility8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.1 cm
Package 1 Width8.2 cm
Package 1 Length10 cm
Package 1 Weight202 g
Unit Type of Package 2BB1
Number of Units in Package 26
Package 2 Height10.5 cm
Package 2 Width9.5 cm
Package 2 Length25.5 cm
Package 2 Weight1.307 kg
Unit Type of Package 3S03
Number of Units in Package 354
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight12.409 kg

A9R75240

RangeActi9
Product nameActi9 iID K
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID K
Poles description2P
Neutral positionLeft
[In] rated current40 A
Network typeAC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 500 A
Im 500 A
Rated conditional short-circuit currentGL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Contact position indicatorNo
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height85 mm
Width36 mm
Depth69 mm
Net weight0.21 kg
ColourWhite
Mechanical durability5000 cycles
Electrical durabilityAC-1: 2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Electromagnetic compatibility8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.5 cm
Package 1 Width4 cm
Package 1 Length10 cm
Package 1 Weight202 g
Unit Type of Package 2BB1
Number of Units in Package 26
Package 2 Height10.5 cm
Package 2 Width9 cm
Package 2 Length25.5 cm
Package 2 Weight1.311 kg
Unit Type of Package 3S03
Number of Units in Package 354
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight12.03 kg

A9R75425

RangeActi9
Product nameActi9 iID K
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID K
Poles description4P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Quality labelsVDE
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 500 A
Im 500 A
Rated conditional short-circuit currentGL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Contact position indicatorNo
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches8
Height85 mm
Width72 mm
Depth69 mm
Net weight0.37 kg
ColourWhite
Mechanical durability5000 cycles
Electrical durabilityAC-1: 2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Electromagnetic compatibility8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.5 cm
Package 1 Width8.5 cm
Package 1 Length10 cm
Package 1 Weight352 g
Unit Type of Package 2BB1
Number of Units in Package 23
Package 2 Height9 cm
Package 2 Width10.5 cm
Package 2 Length25.5 cm
Package 2 Weight1.152 kg
Unit Type of Package 3S03
Number of Units in Package 327
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight11.028 kg

A9R75440

RangeActi9
Product nameActi9 iID K
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID K
Poles description4P
Neutral positionLeft
[In] rated current40 A
Network typeAC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Quality labelsVDE
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 500 A
Im 500 A
Rated conditional short-circuit currentGL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Contact position indicatorNo
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches8
Height85 mm
Width72 mm
Depth69 mm
Net weight0.37 kg
ColourWhite
Mechanical durability5000 cycles
Electrical durabilityAC-1: 2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Electromagnetic compatibility8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.5 cm
Package 1 Width8.2 cm
Package 1 Length10 cm
Package 1 Weight352 g
Unit Type of Package 2BB1
Number of Units in Package 23
Package 2 Height9 cm
Package 2 Width10.7 cm
Package 2 Length25.5 cm
Package 2 Weight1.147 kg
Unit Type of Package 3S03
Number of Units in Package 327
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight11.08 kg

M9R11225

RangeMulti9
Product nameMulti9 ID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameID
Device applicationDistribution
Poles description2P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 250 A conforming to EN/IEC 61008-1
Rated conditional short-circuit currentInc 10 kA
[Ui] rated insulation voltage440 V AC 50 Hz conforming to EN/IEC 61008-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 61008-1
Surge current250 A
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height81 mm
Width36 mm
Depth73 mm
Net weight0.23 kg
ColourGrey
Mechanical durability20000 cycles
Electrical durability2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminal (top or bottom) 1…35 mm² – rigid
Tunnel type terminal (top or bottom) 1…25 mm² – flexible
Tunnel type terminal (top or bottom) 3 cable(s) 16 mm² – rigid
Tunnel type terminal (top or bottom) 3 cable(s) 10 mm² – flexible
Tunnel type terminal (top or bottom) 1…25 mm² – flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
Product certificationsCE
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…40 °C
Ambient air temperature for storage-40…60 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.5 cm
Package 1 Length8.7 cm
Package 1 Weight205 g
Unit Type of Package 2S03
Number of Units in Package 236
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight7.821 kg
Unit Type of Package 3P12
Number of Units in Package 3288
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight74.568 kg

M9R11240

RangeMulti9
Product nameMulti9 ID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameID
Device applicationDistribution
Poles description2P
Neutral positionLeft
[In] rated current40 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 400 A conforming to EN/IEC 61008-1
Rated conditional short-circuit currentInc 10 kA
[Ui] rated insulation voltage440 V AC 50 Hz conforming to EN/IEC 61008-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 61008-1
Surge current250 A
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height81 mm
Width36 mm
Depth73 mm
Net weight0.23 kg
ColourGrey
Mechanical durability20000 cycles
Electrical durability2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminal (top or bottom) 1…35 mm² – rigid
Tunnel type terminal (top or bottom) 1…25 mm² – flexible
Tunnel type terminal (top or bottom) 3 cable(s) 16 mm² – rigid
Tunnel type terminal (top or bottom) 3 cable(s) 10 mm² – flexible
Tunnel type terminal (top or bottom) 1…25 mm² – flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
Product certificationsCE
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…40 °C
Ambient air temperature for storage-40…60 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.5 cm
Package 1 Length9.0 cm
Package 1 Weight205 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.511 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight104.088 kg