Range Acti9 Product name Acti9 iID Product or component type Residual current circuit breaker (RCCB) Device short name IID Poles description 2P Neutral position Left [In] rated current 25 A Network type AC Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 220…240 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 1500 A
Im 1500 ARated conditional short-circuit current 10 kA [Ui] rated insulation voltage 500 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 6 kV Surge current 250 A Contact position indicator Yes Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 4 Height 91 mm Width 36 mm Depth 73.5 mm Net weight 0.21 kg Colour White Mechanical durability 20000 cycles Electrical durability AC-1: 15000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferruleWire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1
EN/IEC 61008-2-1IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 4 cm Package 1 Width 8 cm Package 1 Length 10 cm Package 1 Weight 210 g Unit Type of Package 2 S03 Number of Units in Package 2 54 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 11.781 kg Unit Type of Package 3 P12 Number of Units in Package 3 432 Package 3 Height 44.4 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 106.248 kg
A9D31606
Range Acti9 Product name Acti9 iDPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name IDPN N Vigi Device application Distribution Poles description 1P + N Number of protected poles 1 Neutral position Left [In] rated current 6 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Complementary Outgoer Network frequency 50 Hz [Ue] rated operational voltage 220…240 V AC 50 Hz Magnetic tripping limit 5…10 x In residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 400 V AC 50 Hz [Uimp] rated impulse withstand voltage 4 kV Contact position indicator Yes Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Connection pitch 9 mm between phase and neutral 9 mm pitches 4 Height 85 mm Width 36 mm Depth 73 mm Net weight 125 g Colour White Mechanical durability 20000 cycles Electrical durability 20000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferruleWire stripping length 15 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Integrated Standards EN/IEC 61009-2-1 Product certifications VDE
GOSTIP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 4.0 cm Package 1 Width 8.5 cm Package 1 Length 10.0 cm Package 1 Weight 208 g Unit Type of Package 2 S03 Number of Units in Package 2 54 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 11.673 kg Unit Type of Package 3 P12 Number of Units in Package 3 432 Package 3 Height 44.4 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 105.384 kg
A9D31610
Range Acti9 Product name Acti9 iDPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name IDPN N Vigi Device application Distribution Poles description 1P + N Number of protected poles 1 Neutral position Left [In] rated current 10 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Complementary Outgoer Network frequency 50 Hz [Ue] rated operational voltage 220…240 V AC 50 Hz Magnetic tripping limit 5…10 x In residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 400 V AC 50 Hz [Uimp] rated impulse withstand voltage 4 kV Contact position indicator Yes Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Connection pitch 9 mm between phase and neutral 9 mm pitches 4 Height 85 mm Width 36 mm Depth 73 mm Net weight 125 g Colour White Mechanical durability 20000 cycles Electrical durability 20000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferruleWire stripping length 15 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Integrated Standards EN/IEC 61009-2-1 Product certifications VDE
GOSTIP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 4.0 cm Package 1 Width 8.5 cm Package 1 Length 10.0 cm Package 1 Weight 213 g Unit Type of Package 2 S03 Number of Units in Package 2 54 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 11.943 kg Unit Type of Package 3 P12 Number of Units in Package 3 432 Package 3 Height 44.4 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 107.544 kg
A9D31616
Range Acti9 Product name Acti9 iDPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name IDPN N Vigi Device application Distribution Poles description 1P + N Number of protected poles 1 Neutral position Left [In] rated current 16 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Complementary Outgoer Network frequency 50 Hz [Ue] rated operational voltage 220…240 V AC 50 Hz Magnetic tripping limit 5…10 x In residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 400 V AC 50 Hz [Uimp] rated impulse withstand voltage 4 kV Contact position indicator Yes Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Connection pitch 9 mm between phase and neutral 9 mm pitches 4 Height 85 mm Width 36 mm Depth 73 mm Net weight 125 g Colour White Mechanical durability 20000 cycles Electrical durability 20000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferruleWire stripping length 15 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Integrated Standards EN/IEC 61009-2-1 Product certifications VDE
GOSTIP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 4.0 cm Package 1 Width 8.0 cm Package 1 Length 10.0 cm Package 1 Weight 209 g Unit Type of Package 2 S03 Number of Units in Package 2 54 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 11.727 kg Unit Type of Package 3 P12 Number of Units in Package 3 432 Package 3 Height 44.4 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 105.816 kg
A9D31625
Range Acti9 Product name Acti9 iDPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name IDPN N Vigi Device application Distribution Poles description 1P + N Number of protected poles 1 Neutral position Left [In] rated current 25 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Device location in system Outgoer Network frequency 50 Hz [Ue] rated operational voltage 220…240 V AC 50 Hz Magnetic tripping limit 5…10 x In residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 400 V AC 50 Hz [Uimp] rated impulse withstand voltage 4 kV Contact position indicator Yes Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Connection pitch 9 mm between phase and neutral 9 mm pitches 4 Height 85 mm Width 36 mm Depth 73 mm Net weight 125 g Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferruleWire stripping length 15 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Integrated Standards EN/IEC 61009-2-1 Product certifications VDE
GOSTIP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 4.0 cm Package 1 Width 8.0 cm Package 1 Length 10.0 cm Package 1 Weight 209 g Unit Type of Package 2 S03 Number of Units in Package 2 54 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 11.727 kg Unit Type of Package 3 P12 Number of Units in Package 3 432 Package 3 Height 44.4 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 105.816 kg
A9D31632
Range Acti9 Product name Acti9 iDPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name IDPN N Vigi Device application Distribution Poles description 1P + N Number of protected poles 1 Neutral position Left [In] rated current 32 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Device location in system Outgoer Network frequency 50 Hz [Ue] rated operational voltage 220…240 V AC 50 Hz Magnetic tripping limit 5…10 x In residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 400 V AC 50 Hz [Uimp] rated impulse withstand voltage 4 kV Contact position indicator Yes Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Connection pitch 9 mm between phase and neutral 9 mm pitches 4 Height 85 mm Width 36 mm Depth 73 mm Net weight 125 g Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferruleWire stripping length 15 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Integrated Standards EN/IEC 61009-2-1 Product certifications VDE
GOSTIP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 4 cm Package 1 Width 8.5 cm Package 1 Length 10 cm Package 1 Weight 224 g Unit Type of Package 2 BB1 Number of Units in Package 2 6 Package 2 Height 9 cm Package 2 Width 10.7 cm Package 2 Length 25.5 cm Package 2 Weight 1.406 kg Unit Type of Package 3 S03 Number of Units in Package 3 54 Package 3 Height 30 cm Package 3 Width 30 cm Package 3 Length 40 cm Package 3 Weight 13.179 kg
A9D31640
Range Acti9 Product name Acti9 iDPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name IDPN N Vigi Device application Distribution Poles description 1P + N Number of protected poles 1 Neutral position Left [In] rated current 40 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Complementary Outgoer Network frequency 50 Hz [Ue] rated operational voltage 220…240 V AC 50 Hz Magnetic tripping limit 5…10 x In residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 400 V AC 50 Hz [Uimp] rated impulse withstand voltage 4 kV Contact position indicator Yes Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Connection pitch 9 mm between phase and neutral 9 mm pitches 4 Height 85 mm Width 36 mm Depth 73 mm Net weight 125 g Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferruleWire stripping length 15 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Integrated Standards EN/IEC 61009-2-1 Product certifications VDE
GOSTIP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 95 % at 55 °C Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 4.0 cm Package 1 Width 8.5 cm Package 1 Length 10.0 cm Package 1 Weight 226 g Unit Type of Package 2 S03 Number of Units in Package 2 54 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 12.645 kg Unit Type of Package 3 P12 Number of Units in Package 3 432 Package 3 Height 44.4 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 113.160 kg
A9D31710
Range Acti9 Product name Acti9 DPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name DPN N Vigi Device application Distribution Poles description 3P + N Number of protected poles 3 Neutral position Left [In] rated current 10 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz Magnetic tripping limit 5…10 x In residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 440 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 4 kV Contact position indicator Yes Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Connection pitch 18 mm between phases
9 mm between phase and neutral9 mm pitches 10 Height 91 mm Width 90 mm Depth 78.5 mm Net weight 498 g Colour White Mechanical durability 20000 cycles Electrical durability 20000 cycles Locking options description Padlocking device
SealableConnections – terminals Tunnel type terminal top or bottom 0.75…16 mm² rigid
Tunnel type terminal top or bottom 0.33…10 mm² flexible
Tunnel type terminal top or bottom 0.33…10 mm² flexible with ferruleWire stripping length 15 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Integrated Standards EN/IEC 61009-2-1 IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 90 % at 55 °C Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -30…70 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 8.9 cm Package 1 Width 11.3 cm Package 1 Length 16.2 cm Package 1 Weight 553 g
A9D31732
Range Acti9 Product name Acti9 DPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name DPN N Vigi Device application Distribution Poles description 3P + N Number of protected poles 3 Neutral position Left [In] rated current 32 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz Magnetic tripping limit 5…10 x In residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 440 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 4 kV Contact position indicator Yes Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Connection pitch 18 mm between phases
9 mm between phase and neutral9 mm pitches 10 Height 91 mm Width 90 mm Depth 78.5 mm Net weight 498 g Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Locking options description Padlocking device
SealableConnections – terminals Tunnel type terminal top or bottom 0.75…16 mm² rigid
Tunnel type terminal top or bottom 0.33…10 mm² flexible
Tunnel type terminal top or bottom 0.33…10 mm² flexible with ferruleWire stripping length 15 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Integrated Standards EN/IEC 61009-2-1 IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 90 % at 55 °C Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -30…70 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9 cm Package 1 Width 11 cm Package 1 Length 16 cm Package 1 Weight 578 g
A9D31740
Range Acti9 Product name Acti9 DPN Vigi Product or component type Residual current breaker with overcurrent protection (RCBO) Device short name DPN N Vigi Device application Distribution Poles description 3P + N Number of protected poles 3 Neutral position Left [In] rated current 40 A Network type AC Trip unit technology Thermal-magnetic Curve code C Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Breaking capacity 6000 A Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 Suitability for isolation Yes conforming to EN/IEC 60947-2 Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz Magnetic tripping limit 5…10 x In residual current tripping technology Voltage independent [Ics] rated service breaking capacity 6000 A 100 % x Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 Rated breaking and making capacity Idm 6000 A at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1 Limitation class 3 conforming to EN/IEC 61009-2-1 [Ui] rated insulation voltage 440 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 4 kV Contact position indicator Yes Control type Toggle Local signalling ON, OFF, fault trip Mounting mode Clip-on Mounting support DIN rail Comb busbar and distribution block compatibility Top or bottom: YES Connection pitch 18 mm between phases
9 mm between phase and neutral9 mm pitches 10 Height 91 mm Width 90 mm Depth 78.5 mm Net weight 498 g Colour White Mechanical durability 20000 cycles Electrical durability 10000 cycles Locking options description Padlocking device
SealableConnections – terminals Tunnel type terminal top or bottom 0.75…16 mm² rigid
Tunnel type terminal top or bottom 0.33…10 mm² flexible
Tunnel type terminal top or bottom 0.33…10 mm² flexible with ferruleWire stripping length 15 mm for top or bottom connection Tightening torque 2 N.m top or bottom Earth-leakage protection Integrated Standards EN/IEC 61009-2-1 IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Overvoltage category III conforming to IEC 60364 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1 Tropicalisation 2 conforming to IEC 60068-1 Relative humidity 90 % at 55 °C Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -30…70 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 9 cm Package 1 Width 11 cm Package 1 Length 16 cm Package 1 Weight 585 g