همه محصولات
- اشنایدر الکتریک589 محصول
- overcurrent-relay-schneider-electric0 محصول
- اتوماسیون صنعتی (PLC)229 محصول
- الکتریکال262 محصول
- درایو – اینورتر52 محصول
- سافت استارتر46 محصول
- زیمنس3,624 محصول
- همه محصولات3,619 محصول
فیلترها
M9R11240
Range | Multi9 |
---|---|
Product name | Multi9 ID |
Product or component type | Residual current circuit breaker (RCCB) |
Device short name | ID |
Device application | Distribution |
Poles description | 2P |
Neutral position | Left |
[In] rated current | 40 A |
Network type | AC |
Earth-leakage sensitivity | 30 mA |
Earth-leakage protection time delay | Instantaneous |
Earth-leakage protection class | Type AC |
Network frequency | 50 Hz |
---|---|
[Ue] rated operational voltage | 220…240 V AC 50 Hz |
residual current tripping technology | Voltage independent |
Rated breaking and making capacity | Idm 400 A conforming to EN/IEC 61008-1 |
Rated conditional short-circuit current | Inc 10 kA |
[Ui] rated insulation voltage | 440 V AC 50 Hz conforming to EN/IEC 61008-1 |
[Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 61008-1 |
Surge current | 250 A |
Contact position indicator | Yes |
Control type | Toggle |
Local signalling | ON, OFF, fault trip |
Mounting mode | Clip-on |
Mounting support | DIN rail |
9 mm pitches | 4 |
Height | 81 mm |
Width | 36 mm |
Depth | 73 mm |
Net weight | 0.23 kg |
Colour | Grey |
Mechanical durability | 20000 cycles |
Electrical durability | 2000 cycles |
Locking options description | Padlocking device |
Connections – terminals | Tunnel type terminal (top or bottom) 1…35 mm² – rigid Tunnel type terminal (top or bottom) 1…25 mm² – flexible Tunnel type terminal (top or bottom) 3 cable(s) 16 mm² – rigid Tunnel type terminal (top or bottom) 3 cable(s) 10 mm² – flexible Tunnel type terminal (top or bottom) 1…25 mm² – flexible with ferrule |
Wire stripping length | 15 mm for top or bottom connection |
Tightening torque | 3.5 N.m top or bottom |
Standards | EN/IEC 61008-1 |
---|---|
Product certifications | CE |
IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
Pollution degree | 3 |
Electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 |
Tropicalisation | 2 conforming to IEC 60068-1 |
Relative humidity | 95 % at 55 °C |
Ambient air temperature for operation | -5…40 °C |
Ambient air temperature for storage | -40…60 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 4.0 cm |
Package 1 Width | 8.5 cm |
Package 1 Length | 9.0 cm |
Package 1 Weight | 205 g |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 54 |
Package 2 Height | 30.0 cm |
Package 2 Width | 30.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 11.511 kg |
Unit Type of Package 3 | P12 |
Number of Units in Package 3 | 432 |
Package 3 Height | 44.4 cm |
Package 3 Width | 80 cm |
Package 3 Length | 120 cm |
Package 3 Weight | 104.088 kg |
METSEDM6200
Range of product PowerLogic Device short name DM6200 Product or component type Multimeter Device application Equipment monitoring
Power monitoring
Preventive maintenanceType of measurement Current
Voltage
Frequency
Power factor
Phase unbalance
Phase angle
RPM[Us] rated supply voltage 44…277 V AC 50/60 Hz
44…277 V DCNetwork frequency 45…65 Hz Maximum power consumption in VA 3 VA at 240 V AC Display type LED indicator Sampling rate 20 samples/cycle Measurement current 5 A
1 AAnalogue input type Current 0.05…6 A (impedance <= 0.1 Ohm) Measurement voltage 80…480 V AC phase to phase Measurement accuracy Frequency 0.1 %
Power factor 1 %
Voltage 1 % 46…277 V
Current 1 % 0.05…6 ACommunication port protocol Modbus Communication port support Terminal block: RS485 Transmission rate 19.2 kbauds Electromagnetic compatibility Electrostatic discharge immunity test: , conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: , conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: , conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: , conforming to IEC 61000-4-5
Conducted RF disturbances: , conforming to IEC 61000-4-6
Immunity to impulse waves: , conforming to IEC 61000-4-12
Conducted and radiated emissions: , A, conforming to CISPR 11
Immunity to microbreaks and voltage drops: , conforming to IEC 61000-4-11Mounting mode Flush-mounted Type of installation Indoor installation Overvoltage category III IP degree of protection IP40 back:
IP51 front face:Pollution degree 2 Ambient air temperature for operation -10…60 °C Ambient air temperature for storage -25…70 °C Relative humidity 95 % Operating altitude 0…2000 m Standards UL 508
IEC 61010Product certifications CE Width 96 mm Depth 80 mm Height 96 mm Net weight 0.4 kg Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 11 cm Package 1 Width 12.5 cm Package 1 Length 12.8 cm Package 1 Weight 537 g
METSEPM1200
Range of product PowerLogic PM1000 Device short name PM1200 Product or component type Power meter Power quality analysis Up to the 9th harmonic Type of measurement Current
Voltage
Frequency
Active and reactive power
Active and reactive energy
Power factorsupply voltage 44…277 V AC 50/60 Hz
44…277 V DCNetwork frequency 50/60 Hz Maximum power consumption in VA 3 VA at 240 V AC Display type LED Display resolution 3 lines with 4 digits Sampling rate 20 samples/cycle Measurement current 50…6000 mA input type Current 0…5 A (impedance <= 0.1 Ohm)
Current 0…1 A (impedance <= 0.1 Ohm)Measurement voltage 80…480 V AC 50/60 Hz phase to phase
0…999000 V AC 50/60 Hz with external VTMeasurement accuracy Power 1 %
Current 1 %
Voltage 1 %
Energy 1 %
Frequency 0.1 %
Power factor 1 %
Apparent power 1 %Accuracy class Class 2 reactive energy conforming to IEC 62053-23
Class 1 active energy conforming to IEC 62053-21Communication port protocol Modbus 19.2 kbauds Communication port support RS485 Electromagnetic compatibility Immunity to impulse waves: , conforming to IEC 61000-4-12
Electrostatic discharge immunity test: , conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: , conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: , conforming to IEC 61000-4-4
Conducted RF disturbances: , conforming to IEC 61000-4-6
1.2/50 µs shock waves immunity test: , conforming to IEC 61000-4-5
Immunity to microbreaks and voltage drops: , conforming to IEC 61000-4-11
Conducted and radiated emissions: , class A, conforming to CISPR 11Mounting mode Flush-mounted Mounting support Panel Type of installation Indoor installation Overvoltage category III IP degree of protection IP51 front face: conforming to IEC 60529
IP40 back: conforming to IEC 60529Relative humidity 5…95 % Ambient air temperature for operation -10…60 °C Ambient air temperature for storage -25…70 °C Operating altitude 0…2000 m Standards IEC 62053-21
IEC 62052-11Width 96 mm Depth 80 mm embedded: Height 96 mm Net weight 0.4 kg
METSEPM2120
- Bill checking to verify that you are only charged for the energy you use
- Aggregation of energy consumption and cost allocation within the same facility
- Energy cost and usage analysis to optimise energy usage
- Metering of electrical parameters to understand your electrical distribution system
Range | EasyLogic |
---|---|
Product name | EasyLogic PM2100 |
Device short name | PM2120 |
Product or component type | Power meter |
Device application | Sub billing Power monitoring |
---|---|
Power quality analysis | Total harmonic distortion up to the 15th harmonic |
Type of measurement | Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total |
Metering type | Current I, I1, I2, I3 Peak demand power PM, QM, SM Active, reactive, apparent energy (signed, four quadrant) Peak demand currents Active power P, P1, P2, P3 Calculated neutral current Voltage U, U21, U32, U13, V, V1, V2, V3 Unbalance current Reactive power Q, Q1, Q2, Q3 Demand power P, Q, S Apparent power S, S1, S2, S3 |
Accuracy class | Class 1 active energy conforming to IEC 62053-21 Class 1 reactive energy conforming to IEC 62053-24 Class 5 harmonic distorsion (I THD & U THD) |
Measurement accuracy | Apparent power +/- 1 % Active energy +/- 1 % Reactive energy +/- 1 % Active power +/- 1 % Voltage +/- 0.5 % Power factor +/- 0.01 Current +/- 0.5 % Frequency +/- 0.05 % |
Measurement current | 5…6000 mA |
Measurement voltage | 35…480 V AC 50/60 Hz between phases 20…277 V AC 50/60 Hz between phase and neutral 480…999000 V AC 50/60 Hz with external VT |
Frequency measurement range | 45…65 Hz |
[Us] rated supply voltage | 44…277 V AC 45…65 Hz +/- 10 % 44…277 V DC +/- 10 % |
Network frequency | 50 Hz 60 Hz |
Ride-through time | 100 ms 120 V AC typical 400 ms 230 V AC typical 50 ms 125 V DC typical |
[In] rated current | 1 A 5 A |
Maximum power consumption in VA | 6 VA at 277 V AC |
Maximum power consumption in W | 3.3 W (power lines (AC)) 2 W at 277 V (power lines (DC)) |
input impedance | Current (impedance <= 0.3 mOhm) Voltage (impedance > 5 MOhm) |
Tamperproof of settings | Protected by access code |
Display type | 7 segments LED |
Display colour | Red |
messages display capacity | 3 fields of 4 characters |
Display digits | 12 digit(s) – 14.2 mm in height |
Demand intervals | Configurable from 1 to 60 min |
Information displayed | Demand current (past value) Demand current (present value) Demand power (past value) Demand power (present value) Voltage Current Frequency Energy consumption Harmonic distortion Power factor Active power Apparent power Reactive power Unbalanced in % |
Control type | 3 x button |
Local signalling | Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh) Green LED: module operation and integrated communication |
Number of inputs | 0 |
Number of outputs | 0 |
Communication port protocol | Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V |
Communication port support | Screw terminal block: RS485 |
Data recording | Time stamping Min/max for 8 parameters |
Function available | Real time clock |
Sampling rate | 64 samples/cycle |
Cybersecurity | Enable/disable communication ports |
Communication service | Remote monitoring |
Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 RCM EAC C-Tick |
Mounting mode | Clip-on |
Mounting position | Vertical |
Mounting support | Framework |
Provided equipment | 1 x installation guide |
Measurement category | Category III 480 V Category II 480…600 V |
Electrical insulation class | Double insulation Class II |
Flame retardance | V-0 conforming to UL 94 |
Connections – terminals | Current transformer: screw connection (bottom) 6 Voltage inputs: screw connection (top) 4 |
Material | Polycarbonate |
Width | 96 mm |
Depth | 76.09 mm total: 61.64 mm embedded: |
Height | 96 mm |
Net weight | 300 g |
Compatibility code | PM2120 |
Service life | 7 year(s) |
---|---|
IP degree of protection | IP54 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529 |
Relative humidity | 5…95 % at 50 °C |
Pollution degree | 2 |
Ambient air temperature for operation | -10…60 °C |
Ambient air temperature for storage | -25…70 °C |
Operating altitude | <= 2000 m |
Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A |
Overvoltage category | III |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 9.6 cm |
Package 1 Width | 6.72 cm |
Package 1 Length | 10.16 cm |
Package 1 Weight | 302.5 g |
METSEPM2130
Range EasyLogic Product name EasyLogic PM2100 Device short name PM2130 Product or component type Power meter Device application Sub billing
Power monitoringPower quality analysis Total harmonic distortion
up to the 31st harmonicType of measurement Apparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy totalMetering type Peak demand currents
Active power P, P1, P2, P3
Demand power P, Q, S
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Active, reactive, apparent energy (signed, four quadrant)
Voltage U, U21, U32, U13, V, V1, V2, V3
Current I, I1, I2, I3
Calculated neutral current
Unbalance current
Peak demand power PM, QM, SMAccuracy class Class 1 reactive energy conforming to IEC 62053-24
Class 0.5S active energy conforming to IEC 62053-22
Class 5 harmonic distorsion (I THD & U THD)Measurement accuracy Apparent power +/- 0.5 %
Active energy +/- 0.5 %
Reactive energy +/- 1 %
Active power +/- 0.5 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %Measurement current 5…6000 mA Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VTFrequency measurement range 45…65 Hz [Us] rated supply voltage 80…277 V AC 45…65 Hz +/- 10 %
100…277 V DC +/- 10 %Network frequency 50 Hz
60 HzRide-through time 50 ms 120 V AC typical
50 ms 230 V AC typical
50 ms 125 V DC typical[In] rated current 1 A
5 AMaximum power consumption in VA 8 VA at 277 V AC Maximum power consumption in W 3.3 W (power lines (AC))
3.3 W at 277 V (power lines (DC))input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)Tamperproof of settings Protected by access code Display type 7 segments LED Display colour Red messages display capacity 3 fields of 4 characters Display digits 12 digit(s) – 14.2 mm in height Demand intervals Configurable from 1 to 60 min Information displayed Demand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %Control type 3 x button Local signalling Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communicationNumber of inputs 0 Number of outputs 0 Communication port protocol Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V Communication port support Screw terminal block: RS485 Data recording Power logs
Time stamping
Energy consumption logs
Min/max for 8 parametersFunction available Real time clock Sampling rate 64 samples/cycle Cybersecurity Enable/disable communication ports Communication service Remote monitoring Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-TickMounting mode Clip-on Mounting position Vertical Mounting support Framework Provided equipment 1 x installation guide Measurement category Category III 480 V
Category II 480…600 VElectrical insulation class Class II
Double insulationFlame retardance V-0 conforming to UL 94 Connections – terminals Current transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4Material Polycarbonate Width 96 mm Depth 76.09 mm total:
61.64 mm embedded:Height 96 mm Net weight 300 g Compatibility code PM2130 Service life 7 year(s) IP degree of protection IP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529Relative humidity 5…95 % at 50 °C Pollution degree 2 Ambient air temperature for operation -10…60 °C Ambient air temperature for storage -25…70 °C Operating altitude <= 2000 m Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class AOvervoltage category III Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 11.5 cm Package 1 Width 8.7 cm Package 1 Length 12.0 cm Package 1 Weight 404.0 g Unit Type of Package 2 S03 Number of Units in Package 2 18 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 7.71 kg Unit Type of Package 3 P12 Number of Units in Package 3 432 Package 3 Height 80.0 cm Package 3 Width 80.0 cm Package 3 Length 120.0 cm Package 3 Weight 197.112 kg
METSEPM2220
- Bill checking to verify that you are only charged for the energy you use
- Aggregation of energy consumption and cost allocation within the same facility
- Energy cost and usage analysis to optimise energy usage
- Metering of electrical parameters to understand your electrical distribution system
Range EasyLogic Product name EasyLogic PM2200 Device short name PM2220 Product or component type Power meter Device application Power monitoring
Sub billingPower quality analysis Total harmonic distortion
up to the 15th harmonicType of measurement Apparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy totalMetering type Active, reactive, apparent energy (signed, four quadrant)
Current I, I1, I2, I3
Peak demand currents
Peak demand power PM, QM, SM
Unbalance current
Active power P, P1, P2, P3
Reactive power Q, Q1, Q2, Q3
Demand power P, Q, S
Voltage U, U21, U32, U13, V, V1, V2, V3
Apparent power S, S1, S2, S3
Calculated neutral currentAccuracy class Class 1 active energy conforming to IEC 62053-21
Class 1 reactive energy conforming to IEC 62053-24
Class 5 harmonic distorsion (I THD & U THD)Measurement accuracy Apparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 1 %
Active power +/- 1 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %Measurement current 5…6000 mA Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VTFrequency measurement range 45…65 Hz [Us] rated supply voltage 44…277 V AC 45…65 Hz +/- 10 %
44…277 V DC +/- 10 %Network frequency 50 Hz
60 HzRide-through time 100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical[In] rated current 1 A
5 AMaximum power consumption in VA 6 VA at 277 V AC Maximum power consumption in W 3.3 W (power lines (AC))
2 W at 277 V (power lines (DC))input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)Tamperproof of settings Protected by access code Display type Backlit LCD Display colour Monochrome Display resolution 128 x 128 pixels Demand intervals Configurable from 1 to 60 min Information displayed Demand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Harmonic amplitudeControl type 4 x button Local signalling Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communicationNumber of inputs 0 Number of outputs 0 Communication port protocol Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V Communication port support Screw terminal block: RS485 Data recording Time stamping
Min/max for 8 parametersFunction available Real time clock Sampling rate 64 samples/cycle Cybersecurity Enable/disable communication ports Communication service Remote monitoring language Spanish
French
English
Russian
Portuguese
German
ChineseProduct certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-TickMounting mode Clip-on Mounting position Vertical Mounting support Framework Provided equipment 1 x installation guide Measurement category Category III 480 V
Category II 480…600 VElectrical insulation class Double insulation
Class IIFlame retardance V-0 conforming to UL 94 Connections – terminals Current transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4Material Polycarbonate Width 96 mm Depth 76.09 mm total:
61.64 mm embedded:Height 96 mm Net weight 300 g Compatibility code PM2220 Service life 7 year(s) IP degree of protection IP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529Relative humidity 5…95 % at 50 °C Pollution degree 2 Ambient air temperature for operation -10…60 °C Ambient air temperature for storage -25…70 °C Operating altitude <= 2000 m Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class AOvervoltage category III Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 8.9 cm Package 1 Width 12.2 cm Package 1 Length 11.7 cm Package 1 Weight 270 g
METSEPM2230
- Bill checking to verify that you are only charged for the energy you use
- Aggregation of energy consumption and cost allocation within the same facility
- Energy cost and usage analysis to optimise energy usage
- Metering of electrical parameters to understand your electrical distribution system
Range | EasyLogic |
---|---|
Product name | EasyLogic PM2200 |
Device short name | PM2230 |
Product or component type | Power meter |
Device application | Power monitoring Sub billing |
---|---|
Power quality analysis | Total harmonic distortion up to the 31st harmonic |
Type of measurement | Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total |
Metering type | Calculated neutral current Active power P, P1, P2, P3 Current I, I1, I2, I3 Peak demand power PM, QM, SM Voltage U, U21, U32, U13, V, V1, V2, V3 Peak demand currents Reactive power Q, Q1, Q2, Q3 Demand power P, Q, S Unbalance current Active, reactive, apparent energy (signed, four quadrant) Apparent power S, S1, S2, S3 |
Accuracy class | Class 1 reactive energy conforming to IEC 62053-24 Class 0.5S active energy conforming to IEC 62053-22 Class 5 harmonic distorsion (I THD & U THD) |
Measurement accuracy | Apparent power +/- 0.5 % Active energy +/- 0.5 % Reactive energy +/- 1 % Active power +/- 0.5 % Voltage +/- 0.5 % Power factor +/- 0.01 Current +/- 0.5 % Frequency +/- 0.05 % |
Measurement current | 5…6000 mA |
Measurement voltage | 35…480 V AC 50/60 Hz between phases 20…277 V AC 50/60 Hz between phase and neutral 480…999000 V AC 50/60 Hz with external VT |
Frequency measurement range | 45…65 Hz |
[Us] rated supply voltage | 80…277 V AC 45…65 Hz +/- 10 % 100…277 V DC +/- 10 % |
Network frequency | 60 Hz 50 Hz |
Ride-through time | 50 ms 120 V AC typical 50 ms 230 V AC typical 50 ms 125 V DC typical |
[In] rated current | 5 A 1 A |
Maximum power consumption in VA | 8 VA at 277 V AC |
Maximum power consumption in W | 3.3 W (power lines (AC)) 3.3 W at 277 V (power lines (DC)) |
input impedance | Current (impedance <= 0.3 mOhm) Voltage (impedance > 5 MOhm) |
Tamperproof of settings | Protected by access code |
Display type | Backlit LCD |
Display colour | Monochrome |
Display resolution | 128 x 128 pixels |
Demand intervals | Configurable from 1 to 60 min |
Information displayed | Demand current (past value) Demand current (present value) Demand power (past value) Demand power (present value) Voltage Current Frequency Energy consumption Harmonic distortion Power factor Active power Apparent power Reactive power Unbalanced in % Harmonic amplitude |
Control type | 4 x button |
Local signalling | Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh) Green LED: module operation and integrated communication |
Number of inputs | 0 |
Number of outputs | 0 |
Communication port protocol | Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V |
Communication port support | Screw terminal block: RS485 |
Data recording | Energy consumption logs Power logs Time stamping Min/max for 8 parameters |
Function available | Real time clock |
Sampling rate | 64 samples/cycle |
Cybersecurity | Enable/disable communication ports |
Communication service | Remote monitoring |
language | Russian French Portuguese English Spanish Chinese German |
Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 RCM EAC C-Tick |
Mounting mode | Clip-on |
Mounting position | Vertical |
Mounting support | Framework |
Provided equipment | 1 x installation guide |
Measurement category | Category III 480 V Category II 480…600 V |
Electrical insulation class | Double insulation Class II |
Flame retardance | V-0 conforming to UL 94 |
Connections – terminals | Current transformer: screw connection (bottom) 6 Voltage inputs: screw connection (top) 4 |
Material | Polycarbonate |
Width | 96 mm |
Depth | 76.09 mm total: 61.64 mm embedded: |
Height | 96 mm |
Net weight | 300 g |
Compatibility code | PM2230 |
noise level | 76 dB conforming to 86/188/EEC |
---|---|
power dissipation in W | 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz |
operating position | Vertical +/- 10 degree |
electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
pollution degree | 2 conforming to EN/IEC 61800-5-1 |
vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
shock resistance | 6 gn for 11 ms conforming to IEC 60068-2-27 |
relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
ambient air temperature for operation | -15…45 °C (without derating) 45…60 °C (with derating factor) |
operating altitude | <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m |
environmental characteristic | Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 |
standards | EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3 |
marking | CE |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 96.344 kg |
Package 1 Height | 47 cm |
Package 1 width | 67 cm |
Package 1 Length | 103 cm |
NT08H1-47210
range of product MasterPact NT product or component type Basic frame device short name MasterPact NT08 circuit breaker name MasterPact NT08H1 poles description 3P network type AC breaking capacity code H1 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category B network frequency 50/60 Hz control type Push-button mounting mode Drawout [In] rated current 800 A at 40 °C [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2 [Icm] rated short-circuit making capacity 88 kA 220/415 V AC at 50/60 Hz
88 kA 440 V AC at 50/60 Hz
88 kA 525 V AC at 50/60 Hz
88 kA 690 V AC at 50/60 Hz[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 circuit breaker CT rating 800 A breaking capacity 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2protection type Without protection mechanical durability 12500 cycles without maintenance conforming to IEC 60947-2 electrical durability 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-3: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2connection pitch 70 mm [Icw] rated short-time withstand current 24 kA 3 s conforming to IEC 60947-2
42 kA 0.5 s conforming to IEC 60947-2
42 kA 1 s conforming to IEC 60947-2maximum breaking time 25 ms maximum closing response time 50 ms height 322 mm width 288 mm depth 276.5 mm standards IEC 60947-2 product certifications LCIE
ASEFApollution degree 3 conforming to IEC 60664-1 ambient air temperature for operation -25…70 °C ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 23.068 kg Package 1 Height 25.0 cm Package 1 width 40.0 cm Package 1 Length 40.0 cm
NT12H1 – 47140
range of product MasterPact NT product or component type Basic frame device short name MasterPact NT12 circuit breaker name MasterPact NT12H1 poles description 3P network type AC breaking capacity code H1 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category B network frequency 50/60 Hz control type Push-button mounting mode Fixed [In] rated current 1250 A at 40 °C [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2 [Icm] rated short-circuit making capacity 88 kA 220/415 V AC at 50/60 Hz
88 kA 440 V AC at 50/60 Hz
88 kA 525 V AC at 50/60 Hz
88 kA 690 V AC at 50/60 Hz[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 circuit breaker CT rating 1250 A breaking capacity 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2protection type Without protection mechanical durability 12500 cycles without maintenance conforming to IEC 60947-2 electrical durability 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-3: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2connection pitch 70 mm [Icw] rated short-time withstand current 24 kA 3 s conforming to IEC 60947-2
42 kA 0.5 s conforming to IEC 60947-2
42 kA 1 s conforming to IEC 60947-2maximum breaking time 25 ms maximum closing response time 50 ms height 301 mm width 276 mm depth 196 mm standards IEC 60947-2 product certifications ASEFA
LCIEpollution degree 3 conforming to IEC 60664-1 ambient air temperature for operation -25…70 °C ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 21.506 kg Package 1 Height 25.0 cm Package 1 width 40.0 cm Package 1 Length 40.0 cm
NT16H1-47150
range of product MasterPact NT product or component type Basic frame device short name MasterPact NT16 circuit breaker name MasterPact NT16H1 poles description 3P network type AC breaking capacity code H1 suitability for isolation Yes conforming to IEC 60947-2 utilisation category Category B network frequency 50/60 Hz control type Push-button mounting mode Fixed [In] rated current 1600 A at 40 °C [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2 [Icm] rated short-circuit making capacity 88 kA 220/415 V AC at 50/60 Hz
88 kA 440 V AC at 50/60 Hz
88 kA 525 V AC at 50/60 Hz
88 kA 690 V AC at 50/60 Hz[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 circuit breaker CT rating 1600 A breaking capacity 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
42 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 220/415 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
42 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2protection type Without protection mechanical durability 12500 cycles without maintenance conforming to IEC 60947-2 electrical durability 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 3000 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-23A: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2
AC-3: 6000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2connection pitch 70 mm [Icw] rated short-time withstand current 24 kA 3 s conforming to IEC 60947-2
42 kA 0.5 s conforming to IEC 60947-2
42 kA 1 s conforming to IEC 60947-2maximum breaking time 25 ms maximum closing response time 50 ms height 301 mm width 276 mm depth 196 mm standards IEC 60947-2 product certifications LCIE
ASEFApollution degree 3 conforming to IEC 60664-1 ambient air temperature for operation -25…70 °C ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 21.505 kg Package 1 Height 25.0 cm Package 1 width 40.0 cm Package 1 Length 40.0 cm
NW20H13PML2EHH—48287
product line Masterpact NW Product or component type Basic framework Product group Masterpact NW32 circuit breaker name Masterpact NW32H1 Pole definition 3P Network type HUNGRY degree code H1 suitability for insulation Yes conforming to IEC 60947-2 usage category Category B Mains frequency 50/60Hz Control type On/off button Mounting type With drawers [In] rated current 3200 A at 40 °C [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2 [Icm] rated short-circuit making capacity 143 kA 525 V AC at 50/60 Hz
143 kA 690 V AC at 50/60 Hz[Ue] rated operating voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 circuit breaker CT value 3200 A cutting capacity 65 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 65 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2Protection type Without protection mechanical durability 10000 cycles without maintenance conforming to IEC 60947-2
20000 cycles with maintenance conforming to IEC 60947-2electrical endurance AC-3: 6000 cycles 440/690 V AC 50/60 Hz maintenance free conforming to IEC 60947-2
2500 cycles 690 V AC 50/60 Hz maintenance free conforming to IEC 60947-2
5000 cycles 440 V AC 50/60 Hz maintenance without conforming to IEC 60947-2
AC-23A: 2500 cycles 690 V AC 50/60 Hz maintenance free conforming to IEC 60947-2
AC-23A: 5000 cycles 440 V AC 50/60 Hz maintenance free conforming to IEC 60947-2connection range 115mm [Icw] rated short-time withstand current 65 kA 1 s conforming to IEC 60947-2
65 kA 3 s conforming to IEC 60947-2maximum cutting time 25ms Maximum shutdown response time 70 ms height 439mm Width 441mm depth 394.5mm standards IEC 60947-2 Product certificates ASTA degree of contamination 4 conforming to IEC 60664-1 ambient air temperature for operation -25…70 °C Storage ambient conditions -40…85 °C Unit package type 1 PCE Number of units in the package One Package weight (Lbs) 51,236 kg Package 1 Height 30.5 cm Package 1 width 29.5cm Package 1 Length 37.5 cm
NW32H13PML2EHH-48312
product line Masterpact NW Product or component type Basic framework Product group Masterpact NW32 circuit breaker name Masterpact NW32H1 Pole definition 3P Network type HUNGRY degree code H1 suitability for insulation Yes conforming to IEC 60947-2 usage category Category B Mains frequency 50/60Hz Control type On/off button Mounting type With drawers [In] rated current 3200 A at 40 °C [Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 12 kV conforming to IEC 60947-2 [Icm] rated short-circuit making capacity 143 kA 525 V AC at 50/60 Hz
143 kA 690 V AC at 50/60 Hz[Ue] rated operating voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 circuit breaker CT value 3200 A cutting capacity 65 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
65 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service breaking capacity 65 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
65 kA at 690 V AC 50/60 Hz conforming to IEC 60947-2Protection type Without protection mechanical durability 10000 cycles without maintenance conforming to IEC 60947-2
20000 cycles with maintenance conforming to IEC 60947-2electrical endurance AC-3: 6000 cycles 440/690 V AC 50/60 Hz maintenance free conforming to IEC 60947-2
2500 cycles 690 V AC 50/60 Hz maintenance free conforming to IEC 60947-2
5000 cycles 440 V AC 50/60 Hz maintenance without conforming to IEC 60947-2
AC-23A: 2500 cycles 690 V AC 50/60 Hz maintenance free conforming to IEC 60947-2
AC-23A: 5000 cycles 440 V AC 50/60 Hz maintenance free conforming to IEC 60947-2connection range 115mm [Icw] rated short-time withstand current 65 kA 1 s conforming to IEC 60947-2
65 kA 3 s conforming to IEC 60947-2maximum cutting time 25ms Maximum shutdown response time 70 ms height 439mm Width 441mm depth 394.5mm standards IEC 60947-2 Product certificates ASTA degree of contamination 4 conforming to IEC 60664-1 ambient air temperature for operation -25…70 °C Storage ambient conditions -40…85 °C Unit package type 1 PCE Number of units in the package One Package weight (Lbs) 51,236 kg Package 1 Height 30.5 cm Package 1 width 29.5cm Package 1 Length 37.5 cm
P1B100902
|
P1B100911
|
P1B101105
Product | ||
Article Number (Market Facing Number) | P1B101105 | |
Product Description | device: 7SD82 differential protection , 3-pole 2-end expandable with standard variant housing type : flush mounting; BI: 11; BO: 9 (9ST + 0F + 0HS + 0P); I: 4 (protection); U: 4 (standard); measuring transducer inputs: 0 (20 m A or 10 V, fast), 0 (20 m A, normal); housing width: 1/3 x 19”; modules in 19″ row 1: IO 102, PS101, modules in 19″ row 2: ; LEDs/push-buttons: 16 LEDs; operation panel: integrated; keyswitch: without; display type: small display; front design: standard; auxiliary voltage: 110-250 V DC , 100 V – 230 V AC; | |
Product family | Ordering Data Overview | |
Product Lifecycle (PLM) | PM300:Active Product | |
Price data | ||
Region Specific PriceGroup / Headquarter Price Group | B01 / B01 | |
Metal Factor | None | |
Delivery information | ||
Export Control Regulations | AL : N / ECCN : EAR99 | |
Standard lead time ex-works | 20 Day/Days | |
Net Weight (kg) | 2,631 Kg | |
Package size unit of measure | Not available | |
Quantity Unit | 1 Piece | |
Packaging Quantity | 1 | |
Additional Product Information | ||
EAN | Not available | |
UPC | Not available | |
Commodity Code | 85363010 | |
LKZ_FDB/ CatalogID | SIPROTEC | |
Product Group | 1008 | |
Group Code | U321 | |
Country of origin | Germany | |
Compliance with the substance restrictions according to RoHS directive | Since: 14.08.2014 | |
Product class | A: Standard product which is a stock item could be returned within the returns guidelines/period. | |
WEEE (2012/19/EU) Take-Back Obligation | – | |
REACH Art. 33 Duty to inform according to the current list of candidates |
|
|
Classifications | ||
plc-6ES7400-1TA01
399 تومان
range of product
Easy Altivar 610
product or component type
Variable speed drive
product specific application
Fan, pump, compressor, conveyor
device short name
ATV610
variant
Standard version
product destination
Asynchronous motors
mounting mode
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
IP20
type of cooling
Forced convection
supply frequency
50…60 Hz +/-5 %
network number of phases
3 phases
[Us] rated supply voltage
380…460 V – 15…10 %
motor power kW
110 kW for normal duty
90 kW for heavy duty
motor power hp
150 hp for normal duty
125 hp for heavy duty
line current
201 A at 380 V (normal duty)
175.7 A at 460 V (normal duty)
170 A at 380 V (heavy duty)
149.1 A at 460 V (heavy duty)
prospective line Isc
50 kA
apparent power
140.0 kVA at 460 V (normal duty)
118.8 kVA at 460 V (heavy duty)
continuous output current
211 A at 2.5 kHz for normal duty
173 A at 2.5 kHz for heavy duty
maximum transient current
232 A during 60 s (normal duty)
260 A during 60 s (heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
output frequency
0.0001…0.5 kHz
nominal switching frequency
2.5 kHz
switching frequency
1…8 kHz adjustable
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
option card
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
output voltage
<= power supply voltage
motor slip compensation
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 50…3 x 120 mm²
Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type
1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
320 mm
height
852 mm
1159 mm with IP21 conformity kit
depth
390 mm
net weight
82 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number
6
discrete input type
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility
DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm
plc-6ES7405-0KR02-0AA0
1,350,000 تومان
range of product
Easy Altivar 610
product or component type
Variable speed drive
product specific application
Fan, pump, compressor, conveyor
device short name
ATV610
variant
Standard version
product destination
Asynchronous motors
mounting mode
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
IP20
type of cooling
Forced convection
supply frequency
50…60 Hz +/-5 %
network number of phases
3 phases
[Us] rated supply voltage
380…460 V – 15…10 %
motor power kW
110 kW for normal duty
90 kW for heavy duty
motor power hp
150 hp for normal duty
125 hp for heavy duty
line current
201 A at 380 V (normal duty)
175.7 A at 460 V (normal duty)
170 A at 380 V (heavy duty)
149.1 A at 460 V (heavy duty)
prospective line Isc
50 kA
apparent power
140.0 kVA at 460 V (normal duty)
118.8 kVA at 460 V (heavy duty)
continuous output current
211 A at 2.5 kHz for normal duty
173 A at 2.5 kHz for heavy duty
maximum transient current
232 A during 60 s (normal duty)
260 A during 60 s (heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
output frequency
0.0001…0.5 kHz
nominal switching frequency
2.5 kHz
switching frequency
1…8 kHz adjustable
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
option card
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
output voltage
<= power supply voltage
motor slip compensation
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 50…3 x 120 mm²
Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type
1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
320 mm
height
852 mm
1159 mm with IP21 conformity kit
depth
390 mm
net weight
82 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number
6
discrete input type
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility
DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm
Product terminal cover 3-pole 1 unit accessory for: 3VA2 100/160/250 List Price Show prices Customer Price Show prices DataSheet in PDF Download Service & Support (Manuals, Certificates, FAQs…) Download
|
|
|