Range of product |
Harmony XB4 |
Product or component type |
Illuminated push-button |
device short name |
XB4F |
Bezel material |
Chromium plated metal |
Fixing collar material |
Zamak |
Mounting diameter |
30.5 mm |
Sale per indivisible quantity |
1 |
Head type |
Built-in-flush |
Shape of signaling unit head |
Round |
Type of operator |
Spring return |
Operator profile |
Blue flush |
Operator additional information |
With plain lens |
Contacts type and composition |
1 NO + 1 NC |
Contact operation |
Slow-break |
Connections – terminals |
Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1 Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1 |
Light source |
Universal LED |
Bulb base |
Integral LED |
[Us] rated supply voltage |
24 V AC/DC at 50/60 Hz |
Complementary
Height |
47 mm |
Width |
36.6 mm |
Depth |
55 mm |
Terminals description ISO n°1 |
(13-14)NO (21-22)NC |
Product weight |
0.132 kg |
Resistance to high pressure washer |
7000000 Pa at 55 °C, distance : 0.1 m |
Device mounting |
Built-in |
Fixing mode |
By screws recommended torque: 0.8 N.m |
Contacts usage |
Standard contacts |
Positive opening |
With conforming to EN/IEC 60947-5-1 appendix K |
Operating travel |
1.5 mm (NC changing electrical state) 2.6 mm (NO changing electrical state) 4.3 mm (total travel) |
Operating force |
3.5 N NC changing electrical state 3.8 N |
Mechanical durability |
10000000 cycles |
Tightening torque |
0.8…1.2 N.m conforming to EN 60947-1 |
Shape of screw head |
Cross compatible with Philips no 1 screwdriver Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver |
Contacts material |
Silver alloy (Ag/Ni) |
Short-circuit protection |
10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1 |
[Ith] conventional free air thermal current |
10 A conforming to EN/IEC 60947-5-1 |
[Ui] rated insulation voltage |
600 V (pollution degree 3) conforming to EN/IEC 60947-1 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to EN/IEC 60947-1 |
[Ie] rated operational current |
3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1 0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1 1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1 |
Electrical durability |
1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C |
Electrical reliability |
Λ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4 Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4 |
Signalling type |
Steady |
Current consumption |
18 mA |
Service life |
100000 h at rated voltage and 25 °C |
Surge withstand |
1 kV conforming to IEC 61000-4-5 |
Supply voltage limits |
19.2…30 V DC 21.6…26.4 V AC |
Device presentation |
Complete product |
Environment
Protective treatment |
TH |
Ambient air temperature for storage |
-40…70 °C |
Ambient air temperature for operation |
-40…70 °C |
Electrical shock protection class |
Class I conforming to IEC 60536 |
IP degree of protection |
IP66 conforming to IEC 60529 IP67 conforming to IEC 60529 IP69 conforming to IEC 60529 IP69K conforming to ISO 20653 Type 13 conforming to UL 50 E Type 12 conforming to UL 50 E Type 4 conforming to UL 50 E Type 4X conforming to UL 50 E |
IK degree of protection |
IK06 conforming to IEC 50102 |
Standards |
CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60947-5-4 UL 508 EN/IEC 60947-1 JIS C8201-5-1 CE JIS C8201-1 |
Product certifications |
UL listed CSA CCC EAC |
Vibration resistance |
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 2 mm peak to peak (f= 2…10 Hz) conforming to IEC 60068-2-6 |
Shock resistance |
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27 25 gn (duration = 6 ms) for 1000 shocks on each axis conforming to IEC 60068-2-27 |
Resistance to fast transients |
2 kV conforming to IEC 61000-4-4 |
Resistance to electromagnetic fields |
10 V/m conforming to IEC 61000-4-3 |
Resistance to electrostatic discharge |
6 kV on contact (on metal parts) conforming to IEC 61000-4-2 8 kV in free air (in insulating parts) conforming to IEC 61000-4-2 |
Electromagnetic emission |
Class B conforming to IEC 55011 |
Packing Units
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Height |
8.7 cm |
Package 1 Width |
4.3 cm |
Package 1 Length |
5.2 cm |
Package 1 Weight |
127 g |
Unit Type of Package 2 |
S02 |
Number of Units in Package 2 |
40 |
Package 2 Height |
15 cm |
Package 2 Width |
30 cm |
Package 2 Length |
40 cm |
Package 2 Weight |
5.372 kg |