ATS01N106FT

  • range of productEasy Altivar 610
    product or component typeVariable speed drive
    product specific applicationFan, pump, compressor, conveyor
    device short nameATV610
    variantStandard version
    product destinationAsynchronous motors
    mounting modeCabinet mount
    EMC filterIntegrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protectionIP20
    type of coolingForced convection
    supply frequency50…60 Hz +/-5 %
    network number of phases3 phases
    [Us] rated supply voltage380…460 V – 15…10 %
    motor power kW110 kW for normal duty 90 kW for heavy duty
    motor power hp150 hp for normal duty 125 hp for heavy duty
    line current201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc50 kA
    apparent power140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profileVariable torque standard Optimized torque mode Constant torque standard
    output frequency0.0001…0.5 kHz
    nominal switching frequency2.5 kHz
    switching frequency1…8 kHz adjustable
    number of preset speeds16 preset speeds
    communication port protocolModbus serial
    option cardSlot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage<= power supply voltage
    motor slip compensationCan be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration rampsLinear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstillBy DC injection
    protection typeThermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolutionDisplay unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connectionControl, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface2-wire RS 485 for Modbus serial
    transmission frameRTU for Modbus serial
    transmission rate4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarizationNo impedance for Modbus serial
    number of addresses1…247 for Modbus serial
    method of accessSlave
    supplyExternal supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width320 mm
    height852 mm 1159 mm with IP21 conformity kit
    depth390 mm
    net weight82 kg
    analogue input number3
    analogue input typeAI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number6
    discrete input typeDI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibilityDI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logicPositive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number2
    analogue output typeSoftware-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number3
    relay output typeConfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh timeRelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching currentRelay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching currentRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolationBetween power and control terminals
    insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
    noise level76 dB conforming to 86/188/EEC
    power dissipation in W2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating positionVertical +/- 10 degree
    electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree2 conforming to EN/IEC 61800-5-1
    vibration resistance1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation-15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude<= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristicChemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standardsEN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    markingCE
    Unit Type of Package 1PCE
    Number of Units in Package 11
    Package 1 Weight96.344 kg
    Package 1 Height47 cm
    Package 1 width67 cm
    Package 1 Length103 cm