کلید حرارتی اشنایدر

فیلترها

دسته‌بندی را انتخاب کنید

GV3L25

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW11 kW at 400/415 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
18.5 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz
100 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current25 A
Magnetic tripping current350 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight996.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight72.760 kg

GV3L32

Main
RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Complementary
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz
100 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current32 A
Magnetic tripping current448 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Tightening torque5 N.m - on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 Hz
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width16.000 cm
Package 1 Length14.500 cm
Package 1 Weight989.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight72.340 kg

GV3L326

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz
100 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current32 A
Magnetic tripping current448 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.5 cm
Package 1 Width5.5 cm
Package 1 Length13.6 cm
Package 1 Weight898 g

GV3L40

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes
  • (GV2,GV3,GV4)Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current50 A
Magnetic tripping current700 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width16.000 cm
Package 1 Length14.500 cm
Package 1 Weight997.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight73.060 kg

GV3L50

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

Main
RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Complementary
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW30 kW at 400/415 V AC 50/60 Hz
37 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current65 A
Magnetic tripping current910 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Tightening torque5 N.m - on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 Hz
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight1.006 kg
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight136.480 kg

GV3L65

Main
RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Complementary
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW30 kW at 400/415 V AC 50/60 Hz
37 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current65 A
Magnetic tripping current910 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Tightening torque5 N.m - on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 Hz
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight1.006 kg
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight136.480 kg

GV3L73

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW37 kW at 400/415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity65 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
60 % at 400/415 V AC 50/60 Hz
60 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current73 A
Magnetic tripping current1120 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability20000 cycles for AC-3 at 415 V In
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 5 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.3 cm
Package 1 Width14.6 cm
Package 1 Length16.0 cm
Package 1 Weight1.017 kg

GV3L731

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW37 kW at 400/415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity65 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
60 % at 400/415 V AC 50/60 Hz
60 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current73 A
Magnetic tripping current1120 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability20000 cycles for AC-3 at 415 V In
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 5 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.8 cm
Package 1 Width6.5 cm
Package 1 Length14.6 cm
Package 1 Weight1.016 kg

GV3L736

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW37 kW at 400/415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity65 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
60 % at 400/415 V AC 50/60 Hz
60 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current73 A
Magnetic tripping current1120 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability20000 cycles for AC-3 at 415 V In
Tightening torque6 N.m – on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Connection pitch17.5 mm without spreaders
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 5 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.8 cm
Package 1 Width6.5 cm
Package 1 Length14.6 cm
Package 1 Weight1.016 kg

GV3L80

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

Main
RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Complementary
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW45 kW at 400/415 V AC 50/60 Hz maximum peak current 750 A
45 kW at 500 V AC 50/60 Hz maximum peak current 750 A
55 kW at 690 V AC 50/60 Hz maximum peak current 750 A
Breaking capacity65 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
60 % at 400/415 V AC 50/60 Hz
60 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current80 A
Magnetic tripping current1120 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability20000 cycles for AC-3 at 415 V In
Tightening torque5 N.m - on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 5 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 Hz
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.8 cm
Package 1 Width6.5 cm
Package 1 Length14.6 cm
Package 1 Weight1.334 kg
Unit Type of Package 2S02
Number of Units in Package 28
Package 2 Height15 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight8.414 kg
Unit Type of Package 3P06
Number of Units in Package 3120
Package 3 Height73.5 cm
Package 3 Width80 cm
Package 3 Length60 cm
Package 3 Weight136.72 kg

GV3P13

Main
RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Complementary
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW5.5 kW at 400/415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
11 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current13 A
Thermal protection adjustment range9…13 A conforming to IEC 60947-4-1
Magnetic tripping current182 A
[Ith] conventional free air thermal current13 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m - on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 Hz
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height15.500 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight982.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight71.920 kg

GV3P131

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW5.5 kW at 400/415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
11 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current13 A
Thermal protection adjustment range9…13 A conforming to IEC 60947-4-1
Magnetic tripping current182 A
[Ith] conventional free air thermal current13 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.0 cm
Package 1 Width6.5 cm
Package 1 Length14.5 cm
Package 1 Weight940.0 g