پاورمیتر اشنایدر، اشنایدر الکتریک
- اشنایدر الکتریک589 محصول
- overcurrent-relay-schneider-electric0 محصول
- اتوماسیون صنعتی (PLC)229 محصول
- الکتریکال262 محصول
- درایو – اینورتر52 محصول
- سافت استارتر46 محصول
- زیمنس3,624 محصول
- همه محصولات3,619 محصول
فیلترها
METSEPM1200
Range of product PowerLogic PM1000 Device short name PM1200 Product or component type Power meter Power quality analysis Up to the 9th harmonic Type of measurement Current
Voltage
Frequency
Active and reactive power
Active and reactive energy
Power factorsupply voltage 44…277 V AC 50/60 Hz
44…277 V DCNetwork frequency 50/60 Hz Maximum power consumption in VA 3 VA at 240 V AC Display type LED Display resolution 3 lines with 4 digits Sampling rate 20 samples/cycle Measurement current 50…6000 mA input type Current 0…5 A (impedance <= 0.1 Ohm)
Current 0…1 A (impedance <= 0.1 Ohm)Measurement voltage 80…480 V AC 50/60 Hz phase to phase
0…999000 V AC 50/60 Hz with external VTMeasurement accuracy Power 1 %
Current 1 %
Voltage 1 %
Energy 1 %
Frequency 0.1 %
Power factor 1 %
Apparent power 1 %Accuracy class Class 2 reactive energy conforming to IEC 62053-23
Class 1 active energy conforming to IEC 62053-21Communication port protocol Modbus 19.2 kbauds Communication port support RS485 Electromagnetic compatibility Immunity to impulse waves: , conforming to IEC 61000-4-12
Electrostatic discharge immunity test: , conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: , conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: , conforming to IEC 61000-4-4
Conducted RF disturbances: , conforming to IEC 61000-4-6
1.2/50 µs shock waves immunity test: , conforming to IEC 61000-4-5
Immunity to microbreaks and voltage drops: , conforming to IEC 61000-4-11
Conducted and radiated emissions: , class A, conforming to CISPR 11Mounting mode Flush-mounted Mounting support Panel Type of installation Indoor installation Overvoltage category III IP degree of protection IP51 front face: conforming to IEC 60529
IP40 back: conforming to IEC 60529Relative humidity 5…95 % Ambient air temperature for operation -10…60 °C Ambient air temperature for storage -25…70 °C Operating altitude 0…2000 m Standards IEC 62053-21
IEC 62052-11Width 96 mm Depth 80 mm embedded: Height 96 mm Net weight 0.4 kg
METSEPM2120
- Bill checking to verify that you are only charged for the energy you use
- Aggregation of energy consumption and cost allocation within the same facility
- Energy cost and usage analysis to optimise energy usage
- Metering of electrical parameters to understand your electrical distribution system
Range | EasyLogic |
---|---|
Product name | EasyLogic PM2100 |
Device short name | PM2120 |
Product or component type | Power meter |
Device application | Sub billing Power monitoring |
---|---|
Power quality analysis | Total harmonic distortion up to the 15th harmonic |
Type of measurement | Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total |
Metering type | Current I, I1, I2, I3 Peak demand power PM, QM, SM Active, reactive, apparent energy (signed, four quadrant) Peak demand currents Active power P, P1, P2, P3 Calculated neutral current Voltage U, U21, U32, U13, V, V1, V2, V3 Unbalance current Reactive power Q, Q1, Q2, Q3 Demand power P, Q, S Apparent power S, S1, S2, S3 |
Accuracy class | Class 1 active energy conforming to IEC 62053-21 Class 1 reactive energy conforming to IEC 62053-24 Class 5 harmonic distorsion (I THD & U THD) |
Measurement accuracy | Apparent power +/- 1 % Active energy +/- 1 % Reactive energy +/- 1 % Active power +/- 1 % Voltage +/- 0.5 % Power factor +/- 0.01 Current +/- 0.5 % Frequency +/- 0.05 % |
Measurement current | 5…6000 mA |
Measurement voltage | 35…480 V AC 50/60 Hz between phases 20…277 V AC 50/60 Hz between phase and neutral 480…999000 V AC 50/60 Hz with external VT |
Frequency measurement range | 45…65 Hz |
[Us] rated supply voltage | 44…277 V AC 45…65 Hz +/- 10 % 44…277 V DC +/- 10 % |
Network frequency | 50 Hz 60 Hz |
Ride-through time | 100 ms 120 V AC typical 400 ms 230 V AC typical 50 ms 125 V DC typical |
[In] rated current | 1 A 5 A |
Maximum power consumption in VA | 6 VA at 277 V AC |
Maximum power consumption in W | 3.3 W (power lines (AC)) 2 W at 277 V (power lines (DC)) |
input impedance | Current (impedance <= 0.3 mOhm) Voltage (impedance > 5 MOhm) |
Tamperproof of settings | Protected by access code |
Display type | 7 segments LED |
Display colour | Red |
messages display capacity | 3 fields of 4 characters |
Display digits | 12 digit(s) – 14.2 mm in height |
Demand intervals | Configurable from 1 to 60 min |
Information displayed | Demand current (past value) Demand current (present value) Demand power (past value) Demand power (present value) Voltage Current Frequency Energy consumption Harmonic distortion Power factor Active power Apparent power Reactive power Unbalanced in % |
Control type | 3 x button |
Local signalling | Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh) Green LED: module operation and integrated communication |
Number of inputs | 0 |
Number of outputs | 0 |
Communication port protocol | Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V |
Communication port support | Screw terminal block: RS485 |
Data recording | Time stamping Min/max for 8 parameters |
Function available | Real time clock |
Sampling rate | 64 samples/cycle |
Cybersecurity | Enable/disable communication ports |
Communication service | Remote monitoring |
Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 RCM EAC C-Tick |
Mounting mode | Clip-on |
Mounting position | Vertical |
Mounting support | Framework |
Provided equipment | 1 x installation guide |
Measurement category | Category III 480 V Category II 480…600 V |
Electrical insulation class | Double insulation Class II |
Flame retardance | V-0 conforming to UL 94 |
Connections – terminals | Current transformer: screw connection (bottom) 6 Voltage inputs: screw connection (top) 4 |
Material | Polycarbonate |
Width | 96 mm |
Depth | 76.09 mm total: 61.64 mm embedded: |
Height | 96 mm |
Net weight | 300 g |
Compatibility code | PM2120 |
Service life | 7 year(s) |
---|---|
IP degree of protection | IP54 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529 |
Relative humidity | 5…95 % at 50 °C |
Pollution degree | 2 |
Ambient air temperature for operation | -10…60 °C |
Ambient air temperature for storage | -25…70 °C |
Operating altitude | <= 2000 m |
Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A |
Overvoltage category | III |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 9.6 cm |
Package 1 Width | 6.72 cm |
Package 1 Length | 10.16 cm |
Package 1 Weight | 302.5 g |