محافظ جان سه فاز اشنایدر

فیلترها

دسته‌بندی را انتخاب کنید

A9R11480

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description4P
Neutral positionLeft
[In] rated current80 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches8
Height91 mm
Width72 mm
Depth73.5 mm
Net weight0.37 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 10000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
Product certificationsSNI
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.2 cm
Package 1 Width7.5 cm
Package 1 Length10 cm
Package 1 Weight399 g
Unit Type of Package 2S03
Number of Units in Package 227
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight11.387 kg

A9R14491

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description4P
Neutral positionLeft
[In] rated current100 A
Network typeAC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches8
Height91 mm
Width72 mm
Depth73.5 mm
Net weight0.37 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 10000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
Product certificationsSNI
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.5 cm
Package 1 Width8.5 cm
Package 1 Length10 cm
Package 1 Weight356 g
Unit Type of Package 2S03
Number of Units in Package 227
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight10.224 kg

A9R50425

RangeActi9
Product nameActi9 iID K
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID K
Poles description4P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Quality labelsVDE
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 500 A
Im 500 A
Rated conditional short-circuit currentGL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Contact position indicatorNo
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches8
Height85 mm
Width72 mm
Depth69 mm
Net weight0.37 kg
ColourWhite
Mechanical durability5000 cycles
Electrical durabilityAC-1: 2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Electromagnetic compatibility8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.5 cm
Package 1 Width8.5 cm
Package 1 Length10 cm
Package 1 Weight357 g
Unit Type of Package 2S03
Number of Units in Package 227
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight10.257 kg
Unit Type of Package 3P12
Number of Units in Package 3216
Package 3 Height50 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight93.008 kg