GV3P656
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 30 kW at 400/415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 65 A Thermal protection adjustment range 48…65 A conforming to IEC 60947-4-1 Magnetic tripping current 910 A [Ith] conventional free air thermal current 65 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 6 N.m – on lugs-ring terminals Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Connection pitch 17.5 mm without spreaders Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 16.000 cm Package 1 Width 6.500 cm Package 1 Length 14.500 cm Package 1 Weight 927.000 g Unit Type of Package 2 P06 Number of Units in Package 2 60 Package 2 Height 75.000 cm Package 2 Width 60.000 cm Package 2 Length 80.000 cm Package 2 Weight 68.620 kg
GV3P731
range of product | Easy Altivar 610 |
---|---|
product or component type | Variable speed drive |
product specific application | Fan, pump, compressor, conveyor |
device short name | ATV610 |
variant | Standard version |
product destination | Asynchronous motors |
mounting mode | Cabinet mount |
EMC filter | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m |
IP degree of protection | IP20 |
type of cooling | Forced convection |
supply frequency | 50…60 Hz +/-5 % |
network number of phases | 3 phases |
[Us] rated supply voltage | 380…460 V – 15…10 % |
motor power kW | 110 kW for normal duty 90 kW for heavy duty |
motor power hp | 150 hp for normal duty 125 hp for heavy duty |
line current | 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty) |
prospective line Isc | 50 kA |
apparent power | 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty) |
continuous output current | 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty |
maximum transient current | 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty) |
asynchronous motor control profile | Variable torque standard Optimized torque mode Constant torque standard |
output frequency | 0.0001…0.5 kHz |
nominal switching frequency | 2.5 kHz |
switching frequency | 1…8 kHz adjustable |
number of preset speeds | 16 preset speeds |
communication port protocol | Modbus serial |
option card | Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card |
output voltage | <= power supply voltage |
---|---|
motor slip compensation | Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load |
acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 s S, U or customized |
braking to standstill | By DC injection |
protection type | Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive |
frequency resolution | Display unit: 0.1 Hz Analog input: 0.012/50 Hz |
electrical connection | Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm² |
connector type | 1 RJ45 (on the remote graphic terminal) for Modbus serial |
physical interface | 2-wire RS 485 for Modbus serial |
transmission frame | RTU for Modbus serial |
transmission rate | 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
type of polarization | No impedance for Modbus serial |
number of addresses | 1…247 for Modbus serial |
method of access | Slave |
supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
local signalling | 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage |
width | 320 mm |
height | 852 mm 1159 mm with IP21 conformity kit |
depth | 390 mm |
net weight | 82 kg |
analogue input number | 3 |
analogue input type | AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor |
discrete input number | 6 |
discrete input type | DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
input compatibility | DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68 |
discrete input logic | Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
analogue output number | 2 |
analogue output type | Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits |
sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output |
accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output |
relay output number | 3 |
relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
isolation | Between power and control terminals |
insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
noise level | 76 dB conforming to 86/188/EEC |
---|---|
power dissipation in W | 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz |
operating position | Vertical +/- 10 degree |
electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
pollution degree | 2 conforming to EN/IEC 61800-5-1 |
vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
shock resistance | 6 gn for 11 ms conforming to IEC 60068-2-27 |
relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
ambient air temperature for operation | -15…45 °C (without derating) 45…60 °C (with derating factor) |
operating altitude | <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m |
environmental characteristic | Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 |
standards | EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3 |
marking | CE |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 96.344 kg |
Package 1 Height | 47 cm |
Package 1 width | 67 cm |
Package 1 Length | 103 cm |