پاور میتر اشنایدر
- اشنایدر الکتریک589 محصول
- overcurrent-relay-schneider-electric0 محصول
- اتوماسیون صنعتی (PLC)229 محصول
- الکتریکال262 محصول
- درایو – اینورتر52 محصول
- سافت استارتر46 محصول
- زیمنس3,622 محصول
- همه محصولات3,617 محصول
فیلترها
METSEDM6200
Range of product PowerLogic Device short name DM6200 Product or component type Multimeter Device application Equipment monitoring
Power monitoring
Preventive maintenanceType of measurement Current
Voltage
Frequency
Power factor
Phase unbalance
Phase angle
RPM[Us] rated supply voltage 44…277 V AC 50/60 Hz
44…277 V DCNetwork frequency 45…65 Hz Maximum power consumption in VA 3 VA at 240 V AC Display type LED indicator Sampling rate 20 samples/cycle Measurement current 5 A
1 AAnalogue input type Current 0.05…6 A (impedance <= 0.1 Ohm) Measurement voltage 80…480 V AC phase to phase Measurement accuracy Frequency 0.1 %
Power factor 1 %
Voltage 1 % 46…277 V
Current 1 % 0.05…6 ACommunication port protocol Modbus Communication port support Terminal block: RS485 Transmission rate 19.2 kbauds Electromagnetic compatibility Electrostatic discharge immunity test: , conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: , conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: , conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: , conforming to IEC 61000-4-5
Conducted RF disturbances: , conforming to IEC 61000-4-6
Immunity to impulse waves: , conforming to IEC 61000-4-12
Conducted and radiated emissions: , A, conforming to CISPR 11
Immunity to microbreaks and voltage drops: , conforming to IEC 61000-4-11Mounting mode Flush-mounted Type of installation Indoor installation Overvoltage category III IP degree of protection IP40 back:
IP51 front face:Pollution degree 2 Ambient air temperature for operation -10…60 °C Ambient air temperature for storage -25…70 °C Relative humidity 95 % Operating altitude 0…2000 m Standards UL 508
IEC 61010Product certifications CE Width 96 mm Depth 80 mm Height 96 mm Net weight 0.4 kg Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 11 cm Package 1 Width 12.5 cm Package 1 Length 12.8 cm Package 1 Weight 537 g
METSEPM1200
Range of product PowerLogic PM1000 Device short name PM1200 Product or component type Power meter Power quality analysis Up to the 9th harmonic Type of measurement Current
Voltage
Frequency
Active and reactive power
Active and reactive energy
Power factorsupply voltage 44…277 V AC 50/60 Hz
44…277 V DCNetwork frequency 50/60 Hz Maximum power consumption in VA 3 VA at 240 V AC Display type LED Display resolution 3 lines with 4 digits Sampling rate 20 samples/cycle Measurement current 50…6000 mA input type Current 0…5 A (impedance <= 0.1 Ohm)
Current 0…1 A (impedance <= 0.1 Ohm)Measurement voltage 80…480 V AC 50/60 Hz phase to phase
0…999000 V AC 50/60 Hz with external VTMeasurement accuracy Power 1 %
Current 1 %
Voltage 1 %
Energy 1 %
Frequency 0.1 %
Power factor 1 %
Apparent power 1 %Accuracy class Class 2 reactive energy conforming to IEC 62053-23
Class 1 active energy conforming to IEC 62053-21Communication port protocol Modbus 19.2 kbauds Communication port support RS485 Electromagnetic compatibility Immunity to impulse waves: , conforming to IEC 61000-4-12
Electrostatic discharge immunity test: , conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: , conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: , conforming to IEC 61000-4-4
Conducted RF disturbances: , conforming to IEC 61000-4-6
1.2/50 µs shock waves immunity test: , conforming to IEC 61000-4-5
Immunity to microbreaks and voltage drops: , conforming to IEC 61000-4-11
Conducted and radiated emissions: , class A, conforming to CISPR 11Mounting mode Flush-mounted Mounting support Panel Type of installation Indoor installation Overvoltage category III IP degree of protection IP51 front face: conforming to IEC 60529
IP40 back: conforming to IEC 60529Relative humidity 5…95 % Ambient air temperature for operation -10…60 °C Ambient air temperature for storage -25…70 °C Operating altitude 0…2000 m Standards IEC 62053-21
IEC 62052-11Width 96 mm Depth 80 mm embedded: Height 96 mm Net weight 0.4 kg
METSEPM2120
- Bill checking to verify that you are only charged for the energy you use
- Aggregation of energy consumption and cost allocation within the same facility
- Energy cost and usage analysis to optimise energy usage
- Metering of electrical parameters to understand your electrical distribution system
Range | EasyLogic |
---|---|
Product name | EasyLogic PM2100 |
Device short name | PM2120 |
Product or component type | Power meter |
Device application | Sub billing Power monitoring |
---|---|
Power quality analysis | Total harmonic distortion up to the 15th harmonic |
Type of measurement | Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total |
Metering type | Current I, I1, I2, I3 Peak demand power PM, QM, SM Active, reactive, apparent energy (signed, four quadrant) Peak demand currents Active power P, P1, P2, P3 Calculated neutral current Voltage U, U21, U32, U13, V, V1, V2, V3 Unbalance current Reactive power Q, Q1, Q2, Q3 Demand power P, Q, S Apparent power S, S1, S2, S3 |
Accuracy class | Class 1 active energy conforming to IEC 62053-21 Class 1 reactive energy conforming to IEC 62053-24 Class 5 harmonic distorsion (I THD & U THD) |
Measurement accuracy | Apparent power +/- 1 % Active energy +/- 1 % Reactive energy +/- 1 % Active power +/- 1 % Voltage +/- 0.5 % Power factor +/- 0.01 Current +/- 0.5 % Frequency +/- 0.05 % |
Measurement current | 5…6000 mA |
Measurement voltage | 35…480 V AC 50/60 Hz between phases 20…277 V AC 50/60 Hz between phase and neutral 480…999000 V AC 50/60 Hz with external VT |
Frequency measurement range | 45…65 Hz |
[Us] rated supply voltage | 44…277 V AC 45…65 Hz +/- 10 % 44…277 V DC +/- 10 % |
Network frequency | 50 Hz 60 Hz |
Ride-through time | 100 ms 120 V AC typical 400 ms 230 V AC typical 50 ms 125 V DC typical |
[In] rated current | 1 A 5 A |
Maximum power consumption in VA | 6 VA at 277 V AC |
Maximum power consumption in W | 3.3 W (power lines (AC)) 2 W at 277 V (power lines (DC)) |
input impedance | Current (impedance <= 0.3 mOhm) Voltage (impedance > 5 MOhm) |
Tamperproof of settings | Protected by access code |
Display type | 7 segments LED |
Display colour | Red |
messages display capacity | 3 fields of 4 characters |
Display digits | 12 digit(s) – 14.2 mm in height |
Demand intervals | Configurable from 1 to 60 min |
Information displayed | Demand current (past value) Demand current (present value) Demand power (past value) Demand power (present value) Voltage Current Frequency Energy consumption Harmonic distortion Power factor Active power Apparent power Reactive power Unbalanced in % |
Control type | 3 x button |
Local signalling | Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh) Green LED: module operation and integrated communication |
Number of inputs | 0 |
Number of outputs | 0 |
Communication port protocol | Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V |
Communication port support | Screw terminal block: RS485 |
Data recording | Time stamping Min/max for 8 parameters |
Function available | Real time clock |
Sampling rate | 64 samples/cycle |
Cybersecurity | Enable/disable communication ports |
Communication service | Remote monitoring |
Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 RCM EAC C-Tick |
Mounting mode | Clip-on |
Mounting position | Vertical |
Mounting support | Framework |
Provided equipment | 1 x installation guide |
Measurement category | Category III 480 V Category II 480…600 V |
Electrical insulation class | Double insulation Class II |
Flame retardance | V-0 conforming to UL 94 |
Connections – terminals | Current transformer: screw connection (bottom) 6 Voltage inputs: screw connection (top) 4 |
Material | Polycarbonate |
Width | 96 mm |
Depth | 76.09 mm total: 61.64 mm embedded: |
Height | 96 mm |
Net weight | 300 g |
Compatibility code | PM2120 |
Service life | 7 year(s) |
---|---|
IP degree of protection | IP54 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529 |
Relative humidity | 5…95 % at 50 °C |
Pollution degree | 2 |
Ambient air temperature for operation | -10…60 °C |
Ambient air temperature for storage | -25…70 °C |
Operating altitude | <= 2000 m |
Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A |
Overvoltage category | III |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 9.6 cm |
Package 1 Width | 6.72 cm |
Package 1 Length | 10.16 cm |
Package 1 Weight | 302.5 g |
METSEPM2130
Range EasyLogic Product name EasyLogic PM2100 Device short name PM2130 Product or component type Power meter Device application Sub billing
Power monitoringPower quality analysis Total harmonic distortion
up to the 31st harmonicType of measurement Apparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy totalMetering type Peak demand currents
Active power P, P1, P2, P3
Demand power P, Q, S
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Active, reactive, apparent energy (signed, four quadrant)
Voltage U, U21, U32, U13, V, V1, V2, V3
Current I, I1, I2, I3
Calculated neutral current
Unbalance current
Peak demand power PM, QM, SMAccuracy class Class 1 reactive energy conforming to IEC 62053-24
Class 0.5S active energy conforming to IEC 62053-22
Class 5 harmonic distorsion (I THD & U THD)Measurement accuracy Apparent power +/- 0.5 %
Active energy +/- 0.5 %
Reactive energy +/- 1 %
Active power +/- 0.5 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %Measurement current 5…6000 mA Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VTFrequency measurement range 45…65 Hz [Us] rated supply voltage 80…277 V AC 45…65 Hz +/- 10 %
100…277 V DC +/- 10 %Network frequency 50 Hz
60 HzRide-through time 50 ms 120 V AC typical
50 ms 230 V AC typical
50 ms 125 V DC typical[In] rated current 1 A
5 AMaximum power consumption in VA 8 VA at 277 V AC Maximum power consumption in W 3.3 W (power lines (AC))
3.3 W at 277 V (power lines (DC))input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)Tamperproof of settings Protected by access code Display type 7 segments LED Display colour Red messages display capacity 3 fields of 4 characters Display digits 12 digit(s) – 14.2 mm in height Demand intervals Configurable from 1 to 60 min Information displayed Demand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %Control type 3 x button Local signalling Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communicationNumber of inputs 0 Number of outputs 0 Communication port protocol Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V Communication port support Screw terminal block: RS485 Data recording Power logs
Time stamping
Energy consumption logs
Min/max for 8 parametersFunction available Real time clock Sampling rate 64 samples/cycle Cybersecurity Enable/disable communication ports Communication service Remote monitoring Product certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-TickMounting mode Clip-on Mounting position Vertical Mounting support Framework Provided equipment 1 x installation guide Measurement category Category III 480 V
Category II 480…600 VElectrical insulation class Class II
Double insulationFlame retardance V-0 conforming to UL 94 Connections – terminals Current transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4Material Polycarbonate Width 96 mm Depth 76.09 mm total:
61.64 mm embedded:Height 96 mm Net weight 300 g Compatibility code PM2130 Service life 7 year(s) IP degree of protection IP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529Relative humidity 5…95 % at 50 °C Pollution degree 2 Ambient air temperature for operation -10…60 °C Ambient air temperature for storage -25…70 °C Operating altitude <= 2000 m Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class AOvervoltage category III Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 11.5 cm Package 1 Width 8.7 cm Package 1 Length 12.0 cm Package 1 Weight 404.0 g Unit Type of Package 2 S03 Number of Units in Package 2 18 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 7.71 kg Unit Type of Package 3 P12 Number of Units in Package 3 432 Package 3 Height 80.0 cm Package 3 Width 80.0 cm Package 3 Length 120.0 cm Package 3 Weight 197.112 kg
METSEPM2220
- Bill checking to verify that you are only charged for the energy you use
- Aggregation of energy consumption and cost allocation within the same facility
- Energy cost and usage analysis to optimise energy usage
- Metering of electrical parameters to understand your electrical distribution system
Range EasyLogic Product name EasyLogic PM2200 Device short name PM2220 Product or component type Power meter Device application Power monitoring
Sub billingPower quality analysis Total harmonic distortion
up to the 15th harmonicType of measurement Apparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy totalMetering type Active, reactive, apparent energy (signed, four quadrant)
Current I, I1, I2, I3
Peak demand currents
Peak demand power PM, QM, SM
Unbalance current
Active power P, P1, P2, P3
Reactive power Q, Q1, Q2, Q3
Demand power P, Q, S
Voltage U, U21, U32, U13, V, V1, V2, V3
Apparent power S, S1, S2, S3
Calculated neutral currentAccuracy class Class 1 active energy conforming to IEC 62053-21
Class 1 reactive energy conforming to IEC 62053-24
Class 5 harmonic distorsion (I THD & U THD)Measurement accuracy Apparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 1 %
Active power +/- 1 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %Measurement current 5…6000 mA Measurement voltage 35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VTFrequency measurement range 45…65 Hz [Us] rated supply voltage 44…277 V AC 45…65 Hz +/- 10 %
44…277 V DC +/- 10 %Network frequency 50 Hz
60 HzRide-through time 100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical[In] rated current 1 A
5 AMaximum power consumption in VA 6 VA at 277 V AC Maximum power consumption in W 3.3 W (power lines (AC))
2 W at 277 V (power lines (DC))input impedance Current (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)Tamperproof of settings Protected by access code Display type Backlit LCD Display colour Monochrome Display resolution 128 x 128 pixels Demand intervals Configurable from 1 to 60 min Information displayed Demand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Harmonic amplitudeControl type 4 x button Local signalling Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communicationNumber of inputs 0 Number of outputs 0 Communication port protocol Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V Communication port support Screw terminal block: RS485 Data recording Time stamping
Min/max for 8 parametersFunction available Real time clock Sampling rate 64 samples/cycle Cybersecurity Enable/disable communication ports Communication service Remote monitoring language Spanish
French
English
Russian
Portuguese
German
ChineseProduct certifications CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-TickMounting mode Clip-on Mounting position Vertical Mounting support Framework Provided equipment 1 x installation guide Measurement category Category III 480 V
Category II 480…600 VElectrical insulation class Double insulation
Class IIFlame retardance V-0 conforming to UL 94 Connections – terminals Current transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4Material Polycarbonate Width 96 mm Depth 76.09 mm total:
61.64 mm embedded:Height 96 mm Net weight 300 g Compatibility code PM2220 Service life 7 year(s) IP degree of protection IP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529Relative humidity 5…95 % at 50 °C Pollution degree 2 Ambient air temperature for operation -10…60 °C Ambient air temperature for storage -25…70 °C Operating altitude <= 2000 m Electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class AOvervoltage category III Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 8.9 cm Package 1 Width 12.2 cm Package 1 Length 11.7 cm Package 1 Weight 270 g
METSEPM2230
- Bill checking to verify that you are only charged for the energy you use
- Aggregation of energy consumption and cost allocation within the same facility
- Energy cost and usage analysis to optimise energy usage
- Metering of electrical parameters to understand your electrical distribution system
Range | EasyLogic |
---|---|
Product name | EasyLogic PM2200 |
Device short name | PM2230 |
Product or component type | Power meter |
Device application | Power monitoring Sub billing |
---|---|
Power quality analysis | Total harmonic distortion up to the 31st harmonic |
Type of measurement | Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total |
Metering type | Calculated neutral current Active power P, P1, P2, P3 Current I, I1, I2, I3 Peak demand power PM, QM, SM Voltage U, U21, U32, U13, V, V1, V2, V3 Peak demand currents Reactive power Q, Q1, Q2, Q3 Demand power P, Q, S Unbalance current Active, reactive, apparent energy (signed, four quadrant) Apparent power S, S1, S2, S3 |
Accuracy class | Class 1 reactive energy conforming to IEC 62053-24 Class 0.5S active energy conforming to IEC 62053-22 Class 5 harmonic distorsion (I THD & U THD) |
Measurement accuracy | Apparent power +/- 0.5 % Active energy +/- 0.5 % Reactive energy +/- 1 % Active power +/- 0.5 % Voltage +/- 0.5 % Power factor +/- 0.01 Current +/- 0.5 % Frequency +/- 0.05 % |
Measurement current | 5…6000 mA |
Measurement voltage | 35…480 V AC 50/60 Hz between phases 20…277 V AC 50/60 Hz between phase and neutral 480…999000 V AC 50/60 Hz with external VT |
Frequency measurement range | 45…65 Hz |
[Us] rated supply voltage | 80…277 V AC 45…65 Hz +/- 10 % 100…277 V DC +/- 10 % |
Network frequency | 60 Hz 50 Hz |
Ride-through time | 50 ms 120 V AC typical 50 ms 230 V AC typical 50 ms 125 V DC typical |
[In] rated current | 5 A 1 A |
Maximum power consumption in VA | 8 VA at 277 V AC |
Maximum power consumption in W | 3.3 W (power lines (AC)) 3.3 W at 277 V (power lines (DC)) |
input impedance | Current (impedance <= 0.3 mOhm) Voltage (impedance > 5 MOhm) |
Tamperproof of settings | Protected by access code |
Display type | Backlit LCD |
Display colour | Monochrome |
Display resolution | 128 x 128 pixels |
Demand intervals | Configurable from 1 to 60 min |
Information displayed | Demand current (past value) Demand current (present value) Demand power (past value) Demand power (present value) Voltage Current Frequency Energy consumption Harmonic distortion Power factor Active power Apparent power Reactive power Unbalanced in % Harmonic amplitude |
Control type | 4 x button |
Local signalling | Red LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh) Green LED: module operation and integrated communication |
Number of inputs | 0 |
Number of outputs | 0 |
Communication port protocol | Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V |
Communication port support | Screw terminal block: RS485 |
Data recording | Energy consumption logs Power logs Time stamping Min/max for 8 parameters |
Function available | Real time clock |
Sampling rate | 64 samples/cycle |
Cybersecurity | Enable/disable communication ports |
Communication service | Remote monitoring |
language | Russian French Portuguese English Spanish Chinese German |
Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 RCM EAC C-Tick |
Mounting mode | Clip-on |
Mounting position | Vertical |
Mounting support | Framework |
Provided equipment | 1 x installation guide |
Measurement category | Category III 480 V Category II 480…600 V |
Electrical insulation class | Double insulation Class II |
Flame retardance | V-0 conforming to UL 94 |
Connections – terminals | Current transformer: screw connection (bottom) 6 Voltage inputs: screw connection (top) 4 |
Material | Polycarbonate |
Width | 96 mm |
Depth | 76.09 mm total: 61.64 mm embedded: |
Height | 96 mm |
Net weight | 300 g |
Compatibility code | PM2230 |
noise level | 76 dB conforming to 86/188/EEC |
---|---|
power dissipation in W | 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz |
operating position | Vertical +/- 10 degree |
electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
pollution degree | 2 conforming to EN/IEC 61800-5-1 |
vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
shock resistance | 6 gn for 11 ms conforming to IEC 60068-2-27 |
relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
ambient air temperature for operation | -15…45 °C (without derating) 45…60 °C (with derating factor) |
operating altitude | <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m |
environmental characteristic | Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 |
standards | EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3 |
marking | CE |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 96.344 kg |
Package 1 Height | 47 cm |
Package 1 width | 67 cm |
Package 1 Length | 103 cm |