ATV630U15N4
- اشنایدر الکتریک589 محصول
- overcurrent-relay-schneider-electric0 محصول
- اتوماسیون صنعتی (PLC)229 محصول
- الکتریکال262 محصول
- درایو – اینورتر52 محصول
- سافت استارتر46 محصول
- زیمنس3,624 محصول
- همه محصولات3,619 محصول
فیلترها
دستهبندی را انتخاب کنید
ATV630U15N4
range of product | Easy Altivar 610 |
---|---|
product or component type | Variable speed drive |
product specific application | Fan, pump, compressor, conveyor |
device short name | ATV610 |
variant | Standard version |
product destination | Asynchronous motors |
mounting mode | Cabinet mount |
EMC filter | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m |
IP degree of protection | IP20 |
type of cooling | Forced convection |
supply frequency | 50…60 Hz +/-5 % |
network number of phases | 3 phases |
[Us] rated supply voltage | 380…460 V – 15…10 % |
motor power kW | 110 kW for normal duty 90 kW for heavy duty |
motor power hp | 150 hp for normal duty 125 hp for heavy duty |
line current | 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty) |
prospective line Isc | 50 kA |
apparent power | 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty) |
continuous output current | 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty |
maximum transient current | 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty) |
asynchronous motor control profile | Variable torque standard Optimized torque mode Constant torque standard |
output frequency | 0.0001…0.5 kHz |
nominal switching frequency | 2.5 kHz |
switching frequency | 1…8 kHz adjustable |
number of preset speeds | 16 preset speeds |
communication port protocol | Modbus serial |
option card | Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card |
output voltage | <= power supply voltage |
---|---|
motor slip compensation | Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load |
acceleration and deceleration ramps | Linear adjustable separately from 0.01 to 9000 s S, U or customized |
braking to standstill | By DC injection |
protection type | Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive |
frequency resolution | Display unit: 0.1 Hz Analog input: 0.012/50 Hz |
electrical connection | Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm² |
connector type | 1 RJ45 (on the remote graphic terminal) for Modbus serial |
physical interface | 2-wire RS 485 for Modbus serial |
transmission frame | RTU for Modbus serial |
transmission rate | 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial |
type of polarization | No impedance for Modbus serial |
number of addresses | 1…247 for Modbus serial |
method of access | Slave |
supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection |
local signalling | 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage |
width | 320 mm |
height | 852 mm 1159 mm with IP21 conformity kit |
depth | 390 mm |
net weight | 82 kg |
analogue input number | 3 |
analogue input type | AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor |
discrete input number | 6 |
discrete input type | DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) |
input compatibility | DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68 |
discrete input logic | Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1) |
analogue output number | 2 |
analogue output type | Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits |
sampling duration | 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output |
accuracy | +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output |
linearity error | AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output |
relay output number | 3 |
relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
refresh time | Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms) |
minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
isolation | Between power and control terminals |
insulation resistance | > 1 MOhm 500 V DC for 1 minute to earth |
noise level | 76 dB conforming to 86/188/EEC |
---|---|
power dissipation in W | 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz |
operating position | Vertical +/- 10 degree |
electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
pollution degree | 2 conforming to EN/IEC 61800-5-1 |
vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
shock resistance | 6 gn for 11 ms conforming to IEC 60068-2-27 |
relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3 |
ambient air temperature for operation | -15…45 °C (without derating) 45…60 °C (with derating factor) |
operating altitude | <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m |
environmental characteristic | Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 |
standards | EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3 |
marking | CE |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 96.344 kg |
Package 1 Height | 47 cm |
Package 1 width | 67 cm |
Package 1 Length | 103 cm |