GV3P401

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

Main
RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Complementary
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW18.5 kW at 400/415 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current40 A
Thermal protection adjustment range30…40 A conforming to IEC 60947-4-1
Magnetic tripping current560 A
[Ith] conventional free air thermal current40 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m - on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 Hz
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width16.000 cm
Package 1 Length14.700 cm
Package 1 Weight909.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight67.540 kg

GV3P406

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW18.5 kW at 400/415 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current40 A
Thermal protection adjustment range30…40 A conforming to IEC 60947-4-1
Magnetic tripping current560 A
[Ith] conventional free air thermal current40 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque6 N.m – on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Connection pitch17.5 mm without spreaders
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

GV3P50

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current50 A
Thermal protection adjustment range37…50 A conforming to IEC 60947-4-1
Magnetic tripping current700 A
[Ith] conventional free air thermal current50 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight1.008 kg
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight136.960 kg

GV3P501

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current50 A
Thermal protection adjustment range37…50 A conforming to IEC 60947-4-1
Magnetic tripping current700 A
[Ith] conventional free air thermal current50 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height14.600 cm
Package 1 Width6.500 cm
Package 1 Length15.500 cm
Package 1 Weight932.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight68.920 kg

GV3P506

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current50 A
Thermal protection adjustment range37…50 A conforming to IEC 60947-4-1
Magnetic tripping current700 A
[Ith] conventional free air thermal current50 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque6 N.m – on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Connection pitch17.5 mm without spreaders
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Weight96.344 kg
Package 1 Height47 cm
Package 1 width67 cm
Package 1 Length103 cm

GV3P65

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or Component TypeMotor circuit breaker
Device short nameGV3P
Device ApplicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 IEC 60947-4-1
Network frequency50/60 Hz IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail clipped
Panel screwed with 3 x M4 screws)
Motor power kW30 kW 400/415 V AC 50/60 Hz
45 kW 500 V AC 50/60 Hz
55 kW 690 V AC 50/60 Hz
Breaking capacity100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
12 kA Icu 500 V AC 50/60 Hz IEC 60947-2
6 kA Icu 690 V AC 50/60 Hz IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % 230/240 V AC 50/60 Hz IEC 60947-2
100 % 400/415 V AC 50/60 Hz IEC 60947-2
100 % 440 V AC 50/60 Hz IEC 60947-2
50 % 500 V AC 50/60 Hz IEC 60947-2
50 % 690 V AC 50/60 Hz IEC 60947-2
Control TypeRotary handle
Line Rated Current65 A
Thermal protection adjustment range48…65 A IEC 60947-4-1
Magnetic tripping current910 A
[Ith] conventional free air thermal current65 A IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV IEC 60947-2
Phase failure sensitivityYes IEC 60947-4-1
Suitability for isolationYes IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles AC-3 415 V In
Rated dutyContinuous IEC 60947-4-1
Tightening torque44.25 lbf.in (5 N.m) screw clamp terminal
Width2.17 in (55 mm)
Height5.20 in (132 mm)
Depth5.35 in (136 mm)
Net Weight2.12 lb(US) (0.96 kg)
colorDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product CertificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 IEC 60529
Climatic withstandIACS E10
Ambient Air Temperature for Storage-40…176 °F (-40…80 °C)
Fire resistance1760 °F (960 °C) IEC 60695-2-11
Ambient air temperature for operation-4…140 °F (-20…60 °C)
Mechanical robustnessShocks 15 Gn for 11 ms contactor open
Shocks 30 Gn for 11 ms contactor closed
Vibrations 4 Gn, 5…300 Hz
Operating altitude9842.52 ft (3000 m)
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.30 in (16.000 cm)
Package 1 Width2.56 in (6.500 cm)
Package 1 Length5.75 in (14.600 cm)
Package 1 Weight2.24 lb(US) (1.016 kg)
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height29.53 in (75.000 cm)
Package 2 Width23.62 in (60.000 cm)
Package 2 Length31.50 in (80.000 cm)
Package 2 Weight297.45 lb(US) (134.920 kg)

GV3P651

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW30 kW at 400/415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current65 A
Thermal protection adjustment range48…65 A conforming to IEC 60947-4-1
Magnetic tripping current910 A
[Ith] conventional free air thermal current65 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight936.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight70.360 kg

GV3P656

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW30 kW at 400/415 V AC 50/60 Hz
45 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current65 A
Thermal protection adjustment range48…65 A conforming to IEC 60947-4-1
Magnetic tripping current910 A
[Ith] conventional free air thermal current65 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque6 N.m – on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Connection pitch17.5 mm without spreaders
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight927.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight68.620 kg

GV3P73

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3L
Device applicationMotor protection
Trip unit technologyMagnetic
Poles description3P
Network typeAC
Utilisation categoryCategory A conforming to IEC 60947-2
Network frequency50/60 Hz
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
Control typeRotary handle
[In] rated current50 A
Magnetic tripping current700 A
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width16.000 cm
Package 1 Length14.500 cm
Package 1 Weight997.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight73.060 kg

فروشگاه
مقايسه
حساب من