کلید حرارتی اشنایدر
- اشنایدر الکتریک589 محصول
- overcurrent-relay-schneider-electric0 محصول
- اتوماسیون صنعتی (PLC)229 محصول
- الکتریکال262 محصول
- درایو – اینورتر52 محصول
- سافت استارتر46 محصول
- زیمنس3,624 محصول
- همه محصولات3,619 محصول
فیلترها
GV3P136
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 5.5 kW at 400/415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
11 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 13 A Thermal protection adjustment range 9…13 A conforming to IEC 60947-4-1 Magnetic tripping current 182 A [Ith] conventional free air thermal current 13 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 6 N.m – on lugs-ring terminals Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Connection pitch 17.5 mm without spreaders Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1
GV3P186
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 7.5 kW at 400/415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
15 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 18 A Thermal protection adjustment range 12…18 A conforming to IEC 60947-4-1 Magnetic tripping current 252 A [Ith] conventional free air thermal current 18 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 6 N.m – on lugs-ring terminals Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Connection pitch 17.5 mm without spreaders Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1
GV3P25
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 11 kW at 400/415 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
18.5 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 25 A Thermal protection adjustment range 17…25 A conforming to IEC 60947-4-1 Magnetic tripping current 350 A [Ith] conventional free air thermal current 25 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 5 N.m – on screw clamp terminal Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.500 cm Package 1 Width 16.000 cm Package 1 Length 14.500 cm Package 1 Weight 993.000 g Unit Type of Package 2 P06 Number of Units in Package 2 120 Package 2 Height 75.000 cm Package 2 Width 60.000 cm Package 2 Length 80.000 cm Package 2 Weight 132.160 kg
GV3P32
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 32 A Thermal protection adjustment range 23…32 A conforming to IEC 60947-4-1 Magnetic tripping current 448 A [Ith] conventional free air thermal current 32 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 5 N.m – on screw clamp terminal Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 16.000 cm Package 1 Width 6.500 cm Package 1 Length 14.500 cm Package 1 Weight 1.001 kg Unit Type of Package 2 P06 Number of Units in Package 2 120 Package 2 Height 75.000 cm Package 2 Width 60.000 cm Package 2 Length 80.000 cm Package 2 Weight 133.120 kg
GV3P321
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 32 A Thermal protection adjustment range 23…32 A conforming to IEC 60947-4-1 Magnetic tripping current 448 A [Ith] conventional free air thermal current 32 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 5 N.m – on screw clamp terminal Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 16.0 cm Package 1 Width 6.5 cm Package 1 Length 14.5 cm Package 1 Weight 940.0 g
GV3P40
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 18.5 kW at 400/415 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 40 A Thermal protection adjustment range 30…40 A conforming to IEC 60947-4-1 Magnetic tripping current 560 A [Ith] conventional free air thermal current 40 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 5 N.m – on screw clamp terminal Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 16.000 cm Package 1 Width 6.500 cm Package 1 Length 14.600 cm Package 1 Weight 983.000 g Unit Type of Package 2 P06 Number of Units in Package 2 120 Package 2 Height 75.000 cm Package 2 Width 60.000 cm Package 2 Length 80.000 cm Package 2 Weight 133.960 kg
GV3P401
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 18.5 kW at 400/415 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 40 A Thermal protection adjustment range 30…40 A conforming to IEC 60947-4-1 Magnetic tripping current 560 A [Ith] conventional free air thermal current 40 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 5 N.m - on screw clamp terminal Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.500 cm Package 1 Width 16.000 cm Package 1 Length 14.700 cm Package 1 Weight 909.000 g Unit Type of Package 2 P06 Number of Units in Package 2 60 Package 2 Height 75.000 cm Package 2 Width 60.000 cm Package 2 Length 80.000 cm Package 2 Weight 67.540 kg
GV3P406
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 18.5 kW at 400/415 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 40 A Thermal protection adjustment range 30…40 A conforming to IEC 60947-4-1 Magnetic tripping current 560 A [Ith] conventional free air thermal current 40 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 6 N.m – on lugs-ring terminals Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Connection pitch 17.5 mm without spreaders
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm
GV3P50
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 50 A Thermal protection adjustment range 37…50 A conforming to IEC 60947-4-1 Magnetic tripping current 700 A [Ith] conventional free air thermal current 50 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 5 N.m – on screw clamp terminal Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 16.000 cm Package 1 Width 6.500 cm Package 1 Length 14.500 cm Package 1 Weight 1.008 kg Unit Type of Package 2 P06 Number of Units in Package 2 120 Package 2 Height 75.000 cm Package 2 Width 60.000 cm Package 2 Length 80.000 cm Package 2 Weight 136.960 kg
GV3P501
- New modern look & feel of all machines
- Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
- Easier to install and operate with multi-standard screws
- Safe and long-lasting power connection with EverLink terminals
- Digital customer experience for technical documents
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 50 A Thermal protection adjustment range 37…50 A conforming to IEC 60947-4-1 Magnetic tripping current 700 A [Ith] conventional free air thermal current 50 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 5 N.m – on screw clamp terminal Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 14.600 cm Package 1 Width 6.500 cm Package 1 Length 15.500 cm Package 1 Weight 932.000 g Unit Type of Package 2 P06 Number of Units in Package 2 60 Package 2 Height 75.000 cm Package 2 Width 60.000 cm Package 2 Length 80.000 cm Package 2 Weight 68.920 kg
GV3P506
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or component type Motor circuit breaker Device short name GV3P Device application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)Motor power kW 22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 HzBreaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2Control type Rotary handle [In] rated current 50 A Thermal protection adjustment range 37…50 A conforming to IEC 60947-4-1 Magnetic tripping current 700 A [Ith] conventional free air thermal current 50 A conforming to IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Suitability for isolation Yes conforming to IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles for AC-3 at 415 V In Rated duty Continuous conforming to IEC 60947-4-1 Tightening torque 6 N.m – on lugs-ring terminals Width 55 mm Height 132 mm Depth 136 mm Net weight 0.96 kg Colour Dark grey Connection pitch 17.5 mm without spreaders Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 conforming to IEC 60529 Climatic withstand Conforming to IACS E10 Ambient air temperature for storage -40…80 °C Fire resistance 960 °C conforming to IEC 60695-2-11 Ambient air temperature for operation -20…60 °C Mechanical robustness Shocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 HzOperating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 96.344 kg Package 1 Height 47 cm Package 1 width 67 cm Package 1 Length 103 cm
GV3P65
Range TeSys Deca Product name TeSys GV3
TeSys DecaProduct or Component Type Motor circuit breaker Device short name GV3P Device Application Motor protection Trip unit technology Thermal-magnetic Poles description 3P Network type AC Utilisation category AC-3 IEC 60947-4-1 Network frequency 50/60 Hz IEC 60947-4-1 Fixing mode 35 mm symmetrical DIN rail clipped
Panel screwed with 3 x M4 screws)Motor power kW 30 kW 400/415 V AC 50/60 Hz
45 kW 500 V AC 50/60 Hz
55 kW 690 V AC 50/60 HzBreaking capacity 100 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2
50 kA Icu 400/415 V AC 50/60 Hz IEC 60947-2
50 kA Icu 440 V AC 50/60 Hz IEC 60947-2
12 kA Icu 500 V AC 50/60 Hz IEC 60947-2
6 kA Icu 690 V AC 50/60 Hz IEC 60947-2[Ics] rated service short-circuit breaking capacity 100 % 230/240 V AC 50/60 Hz IEC 60947-2
100 % 400/415 V AC 50/60 Hz IEC 60947-2
100 % 440 V AC 50/60 Hz IEC 60947-2
50 % 500 V AC 50/60 Hz IEC 60947-2
50 % 690 V AC 50/60 Hz IEC 60947-2Control Type Rotary handle Line Rated Current 65 A Thermal protection adjustment range 48…65 A IEC 60947-4-1 Magnetic tripping current 910 A [Ith] conventional free air thermal current 65 A IEC 60947-4-1 [Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2 [Ui] rated insulation voltage 690 V AC 50/60 Hz IEC 60947-2 [Uimp] rated impulse withstand voltage 6 kV IEC 60947-2 Phase failure sensitivity Yes IEC 60947-4-1 Suitability for isolation Yes IEC 60947-1 Power dissipation per pole 8 W Mechanical durability 50000 cycles Electrical durability 50000 cycles AC-3 415 V In Rated duty Continuous IEC 60947-4-1 Tightening torque 44.25 lbf.in (5 N.m) screw clamp terminal Width 2.17 in (55 mm) Height 5.20 in (132 mm) Depth 5.35 in (136 mm) Net Weight 2.12 lb(US) (0.96 kg) color Dark grey Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1Product Certifications CCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCAIK degree of protection IK09 enclosure IP degree of protection IP20 IEC 60529 Climatic withstand IACS E10 Ambient Air Temperature for Storage -40…176 °F (-40…80 °C) Fire resistance 1760 °F (960 °C) IEC 60695-2-11 Ambient air temperature for operation -4…140 °F (-20…60 °C) Mechanical robustness Shocks 15 Gn for 11 ms contactor open
Shocks 30 Gn for 11 ms contactor closed
Vibrations 4 Gn, 5…300 HzOperating altitude 9842.52 ft (3000 m) Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 6.30 in (16.000 cm) Package 1 Width 2.56 in (6.500 cm) Package 1 Length 5.75 in (14.600 cm) Package 1 Weight 2.24 lb(US) (1.016 kg) Unit Type of Package 2 P06 Number of Units in Package 2 120 Package 2 Height 29.53 in (75.000 cm) Package 2 Width 23.62 in (60.000 cm) Package 2 Length 31.50 in (80.000 cm) Package 2 Weight 297.45 lb(US) (134.920 kg)