سافت استارتر

فیلترها

دسته‌بندی را انتخاب کنید

ATS01N103FT

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS01N106FT

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS01N109FT

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS01N112FT

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS01N125FT

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS01N206QN

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS01N209QN

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS01N212QN

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS01N222QN

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS01N232QN

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm

ATS22C11Q

  • Provide smooth starting, avoiding mechanical stresses and extending their service life
  • Reduce hearing discomfort for operators on the workfloor
  • Slim form factor improves versatility
  • Less cost to stock spares
  • Overcome difficult or high-torque starts
  • Environmental performance of the product

لینک صفحه اصلی

ATS22C14Q

  • range of product Easy Altivar 610
    product or component type Variable speed drive
    product specific application Fan, pump, compressor, conveyor
    device short name ATV610
    variant Standard version
    product destination Asynchronous motors
    mounting mode Cabinet mount
    EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
    IP degree of protection IP20
    type of cooling Forced convection
    supply frequency 50…60 Hz +/-5 %
    network number of phases 3 phases
    [Us] rated supply voltage 380…460 V – 15…10 %
    motor power kW 110 kW for normal duty 90 kW for heavy duty
    motor power hp 150 hp for normal duty 125 hp for heavy duty
    line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
    prospective line Isc 50 kA
    apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
    continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
    maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
    asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
    output frequency 0.0001…0.5 kHz
    nominal switching frequency 2.5 kHz
    switching frequency 1…8 kHz adjustable
    number of preset speeds 16 preset speeds
    communication port protocol Modbus serial
    option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
    output voltage <= power supply voltage
    motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
    acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
    braking to standstill By DC injection
    protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
    frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
    electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
    connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
    physical interface 2-wire RS 485 for Modbus serial
    transmission frame RTU for Modbus serial
    transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
    type of polarization No impedance for Modbus serial
    number of addresses 1…247 for Modbus serial
    method of access Slave
    supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
    local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
    width 320 mm
    height 852 mm 1159 mm with IP21 conformity kit
    depth 390 mm
    net weight 82 kg
    analogue input number 3
    analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
    discrete input number 6
    discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
    input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
    discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
    analogue output number 2
    analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
    sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
    accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
    linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
    relay output number 3
    relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
    refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
    minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
    maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
    isolation Between power and control terminals
    insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
    noise level 76 dB conforming to 86/188/EEC
    power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
    operating position Vertical +/- 10 degree
    electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
    pollution degree 2 conforming to EN/IEC 61800-5-1
    vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
    shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
    relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
    ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
    operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
    environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
    standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
    marking CE
    Unit Type of Package 1 PCE
    Number of Units in Package 1 1
    Package 1 Weight 96.344 kg
    Package 1 Height 47 cm
    Package 1 width 67 cm
    Package 1 Length 103 cm
فروشگاه
مقايسه
حساب من