PLC اشنایدر

فیلترها

دسته‌بندی را انتخاب کنید

499TWD01100

Range of productTwido
Product or component typeTwidoPort interface module
Current consumption<= 180 mA at 5 V
[Us] rated supply voltage5 V
Supply circuit typeDC
Product compatibilityAll base controllers version >= 3.0
ConceptTransparent Ready
Integrated connection typeEthernet TCP/IP RJ45, , 10/100 Mbit/s, 1 twisted pair transparent ready class A10
Port Ethernet10BASE-T/100BASE-TX
Communication serviceTelnet
BOOTP function
Modbus messaging
Auto MDI/MDX function
SupplySupplied by Twido compact or modular base controller
Supply voltage limits4.5…5.5 V
MarkingCE
Status LED1 LED activity on Ethernet network (ETH ACT)
1 LED activity on the Modbus serial link (SER ACT)
1 LED binary rate 100 Mbit/s (100 MB)
1 LED controller status (STATUS)
1 LED Ethernet link status (LINK)
Net weight0.2 kg
Product certificationsUL
CSA
StandardsFCC Class A
CSA 1010
UL 508
EN 61131-2
Ambient air temperature for operation0…55 °C
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 % without condensation
IP degree of protectionIP20
Operating altitude0…2000 m
Storage altitude0…3000 m
Vibration resistance0.075 mm at 10…57 Hz on 35 mm symmetrical DIN rail
1 gn at 57…150 Hz on 35 mm symmetrical DIN rail
1.6 mm at 2…25 Hz on plate or panel with fixing kit
4 gn at 25…100 Hz on plate or panel with fixing kit
Shock resistance15 gn for 11 ms

 

Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width15.5 cm
Package 1 Length16.0 cm
Package 1 Weight260.0 g
Unit Type of Package 2S03
Number of Units in Package 220
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight5.8 kg

M221CE16T

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221C16R

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221C16T

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221C24R

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221C24T

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

 

TM221C40R

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221C40T

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221CE16R

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221CE16T

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221CE24R

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221CE24T

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221CE40R

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/O
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221CE40T

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221M16R

  • SD card and USB port
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • 2 analog inputs and a broad choice of I/O
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

 

Range of productModicon M221
Product or component typeLogic controller
[Us] rated supply voltage24 V DC
Discrete input number8, discrete input conforming to IEC 61131-2 Type 1
Analogue input number2 at 0…10 V
Discrete output typeRelay normally open
Discrete output number8 relay
Discrete output voltage5…125 V DC
5…250 V AC
Discrete output current2 A
Discrete I/O number16
Maximum number of I/O expansion module7 for relay output
Supply voltage limits20.4…28.8 V
Inrush current35 A
Maximum power consumption in W22.5 W at 24 V (with max number of I/O expansion module)
3.6 W at 24 V (without I/O expansion module)
Power supply output current0.52 A 5 V for expansion bus
0.46 A 24 V for expansion bus
Discrete input logicSink or source (positive/negative)
Discrete input voltage24 V
Discrete input voltage typeDC
Analogue input resolution10 bits
LSB value10 mV
Conversion time1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs+/- 30 V DC for 5 min (maximum) for analog input
+/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed>= 15 V for input
Voltage state 0 guaranteed<= 5 V for input
Discrete input current7 mA for discrete input
5 mA for fast input
Input impedance100 kOhm for analog input
3.4 kOhm for input
4.9 kOhm for fast input
Response time35 µs turn-off, I2…I5 terminal(s) for input
10 ms turn-on for output
10 ms turn-off for output
5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input
35 µs turn-on, other terminals terminal(s) for input
5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input
100 µs turn-off, other terminals terminal(s) for input
Configurable filtering time0 ms for input
3 ms for input
12 ms for input
Output voltage limits125 V DC
277 V AC
Maximum current per output common7 A
Absolute accuracy error+/- 1 % of full scale for analog input
Electrical durability100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency20 switching operations/minute with maximum load
Mechanical durability20000000 cycles for relay output
Minimum load1 mA at 5 V DC for relay output
Protection typeWithout protection at 5 A
Reset time1 s
Memory capacity256 kB for user application and data RAM with 10000 instructions
256 kB for internal variables RAM
Data backed up256 kB built-in flash memory for backup of application and data
Data storage equipment2 GB SD card (optional)
Battery typeBR2032 lithium non-rechargeable, battery life: 4 year(s)
Backup time1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction0.3 ms for event and periodic task
0.7 ms for other instruction
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Application structure1 configurable freewheeling/cyclic master task
1 cyclic auxiliary task
8 interrupt tasks
maximum size of object areas255 %TM timers
8000 %MW memory words
255 %C counters
512 %M memory bits
512 %KW constant words
Realtime clockWith
Clock drift<= 30 s/month at 25 °C
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Counting input number4 fast input (HSC mode) at 100 kHz 32 bits
counter functionPulse/direction
A/B
Single phase
Integrated connection typeUSB port with mini B USB 2.0 connector
Non isolated serial link serial 1 with RJ45 connector and RS485 interface
Non isolated serial link serial 2 with RJ45 connector and RS232/RS485 interface
Supply(Serial 1)serial link supply: 5 V, <200 mA
Transmission rate1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for USB
Communication port protocolUSB port: USB – SoMachine-Network
Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network
Communication serviceModbus slave
Modbus master
Local signalling1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED per channel (green) for I/O state
Electrical connectionTerminal block, 3 terminal(s) for connecting the 24 V DC power supply
connector, 4 terminal(s) for analogue inputs
Mini B USB 2.0 connector for a programming terminal
removable screw terminal block, 10 terminal(s) for inputs
removable screw terminal block, 11 terminal(s) for outputs
Maximum cable distance between devicesShielded cable: <10 m for fast input
Unshielded cable: <30 m for output
Unshielded cable: <30 m for digital input
Unshielded cable: <1 m for analog input
InsulationBetween input and internal logic at 500 V AC
Between fast input and internal logic at 500 V AC
Non-insulated between inputs
Between output and internal logic at 500 V AC
Between output groups at 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
MarkingCE
Mounting supportTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
Height90 mm
Depth70 mm
Width70 mm
Net weight0.264 kg
StandardsEN/IEC 61131-2
EN/IEC 60664-1
EN/IEC 61010-2-201
Product certificationsDNV-GL
ABS
LR
cULus
CSA
RCM
IACS E10
EAC
Environmental characteristicOrdinary and hazardous location
Resistance to electrostatic discharge8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
Resistance to electromagnetic fields10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3
Resistance to magnetic fields30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
Resistance to fast transients2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (I/O) conforming to EN/IEC 61000-4-4
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
Surge withstand2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV I/O common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
Resistance to conducted disturbances10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emissionConducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Radiated emissions – test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions – test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
immunity to microbreaks10 ms
Ambient air temperature for operation-10…55 °C (horizontal installation)
-10…35 °C (vertical installation)
Ambient air temperature for storage-25…70 °C
Relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protectionIP20 with protective cover in place
Pollution degree<= 2
Operating altitude0…2000 m
Storage altitude0…3000 m
Vibration resistance3.5 mm at 5…8.4 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
1 gn at 8.4…150 Hz on symmetrical rail
1 gn at 8.4…150 Hz on panel mounting
Shock resistance98 m/s² for 11 ms
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height10.041 cm
Package 1 Width10.83 cm
Package 1 Length12.81 cm
Package 1 Weight440.0 g
Unit Type of Package 2CAR
Number of Units in Package 224
Package 2 Height29.1 cm
Package 2 Width39.6 cm
Package 2 Length57.8 cm
Package 2 Weight11.66 kg
Unit Type of Package 3P12
Number of Units in Package 3288
Package 3 Height105.0 cm
Package 3 Width120.0 cm
Package 3 Length80.0 cm
Package 3 Weight148 kg

TM221M16T

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

 

TM221M32TK

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221ME16R

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

 

TM221ME16T

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

TM221ME32TK

  • SD card and USB port
  • 2 analog inputs and a broad choice of I/Os
  • Run/stop switch and cartridge extension
  • Ethernet and serial line ports
  • M221 controllers can connect to Modicon TM3 expansion modules for local, remote or distributed I/O configurations

 

TM241C24R

  • Intuitive machine programming with EcoStruxure Machine Expert
  • Ready-to-use applications and function blocks
  • Flexible and scalable machine control allowing an easy upgrade to higher performance platforms to improve efficiency
  • Connected everywhere via Ethernet, wireless access, web servers to simplify machine integration and maintenance

 

TM241C24T

  • Intuitive machine programming with EcoStruxure Machine Expert.
  • Ready-to-use applications and function blocks.
  • Flexible and scalable machine control allowing an easy upgrade to higher performance platforms to improve efficiency.
  • Connected everywhere via Ethernet, wireless access, web servers to simplify machine integration and maintenance.

 

TM241C40R

  • Intuitive machine programming with EcoStruxure Machine Expert.
  • Ready-to-use applications and function blocks.
  • Flexible and scalable machine control allowing an easy upgrade to higher performance platforms to improve efficiency.
  • Connected everywhere via Ethernet, wireless access, web servers to simplify machine integration and maintenance

 

TM241C40T

  • Intuitive machine programming with EcoStruxure Machine Expert.
  • Ready-to-use applications and function blocks.
  • Flexible and scalable machine control allowing an easy upgrade to higher performance platforms to improve efficiency.
  • Connected everywhere via Ethernet, wireless access, web servers to simplify machine integration and maintenance.

 