GV3P136

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW5.5 kW at 400/415 V AC 50/60 Hz
7.5 kW at 500 V AC 50/60 Hz
11 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current13 A
Thermal protection adjustment range9…13 A conforming to IEC 60947-4-1
Magnetic tripping current182 A
[Ith] conventional free air thermal current13 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque6 N.m – on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Connection pitch17.5 mm without spreaders
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11

GV3P18

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW7.5 kW at 400/415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
15 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current18 A
Thermal protection adjustment range12…18 A conforming to IEC 60947-4-1
Magnetic tripping current252 A
[Ith] conventional free air thermal current18 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width16.000 cm
Package 1 Length14.500 cm
Package 1 Weight996.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight72.760 kg

GV3P186

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW7.5 kW at 400/415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
15 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current18 A
Thermal protection adjustment range12…18 A conforming to IEC 60947-4-1
Magnetic tripping current252 A
[Ith] conventional free air thermal current18 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque6 N.m – on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Connection pitch17.5 mm without spreaders
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11

GV3P25

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW11 kW at 400/415 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
18.5 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current25 A
Thermal protection adjustment range17…25 A conforming to IEC 60947-4-1
Magnetic tripping current350 A
[Ith] conventional free air thermal current25 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width16.000 cm
Package 1 Length14.500 cm
Package 1 Weight993.000 g
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight132.160 kg

GV3P256

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW11 kW at 400/415 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
18.5 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current25 A
Thermal protection adjustment range17…25 A conforming to IEC 60947-4-1
Magnetic tripping current350 A
[Ith] conventional free air thermal current25 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque6 N.m – on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Connection pitch17.5 mm without spreaders
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11

GV3P32

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current32 A
Thermal protection adjustment range23…32 A conforming to IEC 60947-4-1
Magnetic tripping current448 A
[Ith] conventional free air thermal current32 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight1.001 kg
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight133.120 kg

GV3P321

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current32 A
Thermal protection adjustment range23…32 A conforming to IEC 60947-4-1
Magnetic tripping current448 A
[Ith] conventional free air thermal current32 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.0 cm
Package 1 Width6.5 cm
Package 1 Length14.5 cm
Package 1 Weight940.0 g

GV3P326

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW15 kW at 400/415 V AC 50/60 Hz
18.5 kW at 500 V AC 50/60 Hz
22 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current32 A
Thermal protection adjustment range23…32 A conforming to IEC 60947-4-1
Magnetic tripping current448 A
[Ith] conventional free air thermal current32 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque6 N.m – on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Connection pitch17.5 mm without spreaders
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.5 cm
Package 1 Width14.5 cm
Package 1 Length16 cm
Package 1 Weight926 g
Unit Type of Package 2S04
Number of Units in Package 216
Package 2 Height30 cm
Package 2 Width40 cm
Package 2 Length60 cm
Package 2 Weight15.988 kg

GV3P40

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW18.5 kW at 400/415 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current40 A
Thermal protection adjustment range30…40 A conforming to IEC 60947-4-1
Magnetic tripping current560 A
[Ith] conventional free air thermal current40 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.600 cm
Package 1 Weight983.000 g
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight133.960 kg

GV3P401

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

Main
RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Complementary
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW18.5 kW at 400/415 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current40 A
Thermal protection adjustment range30…40 A conforming to IEC 60947-4-1
Magnetic tripping current560 A
[Ith] conventional free air thermal current40 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m - on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Environment
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5...300 Hz
Operating altitude3000 m
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height6.500 cm
Package 1 Width16.000 cm
Package 1 Length14.700 cm
Package 1 Weight909.000 g
Unit Type of Package 2P06
Number of Units in Package 260
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight67.540 kg

GV3P406

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW18.5 kW at 400/415 V AC 50/60 Hz
22 kW at 500 V AC 50/60 Hz
37 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current40 A
Thermal protection adjustment range30…40 A conforming to IEC 60947-4-1
Magnetic tripping current560 A
[Ith] conventional free air thermal current40 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque6 N.m – on lugs-ring terminals
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
Connection pitch17.5 mm without spreaders
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

GV3P50

  • New modern look & feel of all machines
  • Wide range of GVs: Magnetic, thermal magnetic, different sizes (GV2,GV3,GV4)
  • Easier to install and operate with multi-standard screws
  • Safe and long-lasting power connection with EverLink terminals
  • Digital customer experience for technical documents

 

RangeTeSys Deca
Product nameTeSys GV3
TeSys Deca
Product or component typeMotor circuit breaker
Device short nameGV3P
Device applicationMotor protection
Trip unit technologyThermal-magnetic
Poles description3P
Network typeAC
Utilisation categoryAC-3 conforming to IEC 60947-4-1
Network frequency50/60 Hz conforming to IEC 60947-4-1
Fixing mode35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Motor power kW22 kW at 400/415 V AC 50/60 Hz
30 kW at 500 V AC 50/60 Hz
45 kW at 690 V AC 50/60 Hz
Breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control typeRotary handle
[In] rated current50 A
Thermal protection adjustment range37…50 A conforming to IEC 60947-4-1
Magnetic tripping current700 A
[Ith] conventional free air thermal current50 A conforming to IEC 60947-4-1
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-2
Phase failure sensitivityYes conforming to IEC 60947-4-1
Suitability for isolationYes conforming to IEC 60947-1
Power dissipation per pole8 W
Mechanical durability50000 cycles
Electrical durability50000 cycles for AC-3 at 415 V In
Rated dutyContinuous conforming to IEC 60947-4-1
Tightening torque5 N.m – on screw clamp terminal
Width55 mm
Height132 mm
Depth136 mm
Net weight0.96 kg
ColourDark grey
StandardsEN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
Product certificationsCCC
UL
CSA
EAC
ATEX
LROS (Lloyds register of shipping)
BV
ABS
DNV-GL
UKCA
IK degree of protectionIK09 enclosure
IP degree of protectionIP20 conforming to IEC 60529
Climatic withstandConforming to IACS E10
Ambient air temperature for storage-40…80 °C
Fire resistance960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation-20…60 °C
Mechanical robustnessShocks: 15 Gn for 11 ms contactor open
Shocks: 30 Gn for 11 ms contactor closed
Vibrations: 4 Gn, 5…300 Hz
Operating altitude3000 m
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height16.000 cm
Package 1 Width6.500 cm
Package 1 Length14.500 cm
Package 1 Weight1.008 kg
Unit Type of Package 2P06
Number of Units in Package 2120
Package 2 Height75.000 cm
Package 2 Width60.000 cm
Package 2 Length80.000 cm
Package 2 Weight136.960 kg