LADN04
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D LC1D
TeSys D CAD
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 4 NC Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL 60947-5-1
600 V conforming to CSA C22.2 No 60947-5-1[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5product certifications IECEE CB Scheme
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
Screw clamp terminals 2 cable(s) 1…2.5 mm²rigidtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2colour Dark grey height 48 mm width 44 mm depth 42 mm net weight 0.05 kg environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN11
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 1 NO + 1 NC Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL 60947-5-1
600 V conforming to CSA C22.2 No 60947-5-1[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5product certifications IECEE CB Scheme
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
Screw clamp terminals 2 cable(s) 1…2.5 mm²rigidtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2colour Dark grey height 48 mm width 26 mm depth 42 mm environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN20
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 2 NO Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL
600 V conforming to CSA[Ith] conventional free air thermal current 10 A (at 60 °C) standards UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5
EN 50012product certifications CB
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable endtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2
1.7 N.m – with screwdriver pozidriv No 2colour Dark grey height 48 mm width 26 mm depth 42 mm environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN22
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 2 NO + 2 NC Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL 60947-5-1
600 V conforming to CSA C22.2 No 60947-5-1[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5product certifications IECEE CB Scheme
UL
CSA
CCC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
Screw clamp terminals 2 cable(s) 1…2.5 mm²rigidtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2colour Dark grey height 48 mm width 44 mm depth 42 mm net weight 0.05 kg environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN31
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 3 NO + 1 NC Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL 60947-5-1
600 V conforming to CSA C22.2 No 60947-5-1[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5product certifications IECEE CB Scheme
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
Screw clamp terminals 2 cable(s) 1…2.5 mm²rigidtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2colour Dark grey height 48 mm width 44 mm depth 42 mm net weight 0.05 kg environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN40
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 4 NO Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL
600 V conforming to CSA[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5
EN 50012product certifications CB
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable endtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2
1.7 N.m – with screwdriver pozidriv No 2colour Dark grey height 48 mm width 44 mm depth 42 mm net weight 0.05 kg environmental characteristic Normal environment IP degree of protection IP2x conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 60.8 g Package 1 Height 4.2 cm Package 1 width 5 cm Package 1 Length 5 cm Unit Type of Package 2 P06 Number of Units in Package 2 1280 Package 2 Weight 89.614 kg Package 2 Height 75 cm Package 2 width 80 cm Package 2 Length 60 cm Unit Type of Package 3 S03 Number of Units in Package 3 160 Package 3 Weight 10.202 kg Package 3 Height 30 cm Package 3 width 30 cm Package 3 Length 40 cm
LC1D09BD
Coil Voltage | 24 V dc |
Number of Poles | 3 |
Contact Current Rating | 9 A |
Power Rating | 4 kW |
Normal State Configuration | 3NO |
Contact Voltage Rating | 690 V ac |
Series | LC1D |
Range | TeSys D |
Number Of Auxiliary Contacts | 2 |
Terminal Type | Screw |
Width | 45mm |
Depth | 93mm |
Minimum Operating Temperature | -5°C |
Length | 77mm |
Maximum Operating Temperature | +60°C |
LC1D12M7
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Contactor device short name LC1D contactor application Resistive load
Motor controlutilisation category AC-4
AC-1
AC-3
AC-3epoles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC[Ie] rated operational current 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3e for power circuitmotor power kW 3 kW at 220…230 V AC 50/60 Hz (AC-3)
5.5 kW at 380…400 V AC 50/60 Hz (AC-3)
5.5 kW at 415…440 V AC 50/60 Hz (AC-3)
7.5 kW at 500 V AC 50/60 Hz (AC-3)
7.5 kW at 660…690 V AC 50/60 Hz (AC-3)
3.7 kW at 400 V AC 50/60 Hz (AC-4)
3 kW at 220…230 V AC 50/60 Hz (AC-3e)
5.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
5.5 kW at 415…440 V AC 50/60 Hz (AC-3e)
7.5 kW at 500 V AC 50/60 Hz (AC-3e)
7.5 kW at 660…690 V AC 50/60 Hz (AC-3e)motor power HP (UL / CSA) 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
3 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 230/240 V AC 50/60 Hz for 3 phases motors
7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
10 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit type AC at 50/60 Hz [Uc] control circuit voltage 220 V AC 50/60 Hz auxiliary contact composition 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 overvoltage category III [Ith] conventional free air thermal current 25 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuitIrms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current 105 A 40 °C – 10 s for power circuit
210 A 40 °C – 1 s for power circuit
30 A 40 °C – 10 min for power circuit
61 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
25 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 2.5 mOhm – Ith 25 A 50 Hz for power circuit [Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certifiedelectrical durability 2 Mcycles 12 A AC-3 at Ue <= 440 V
0.8 Mcycles 25 A AC-1 at Ue <= 440 V
2 Mcycles 12 A AC-3e at Ue <= 440 Vpower dissipation per pole 0.36 W AC-3
1.56 W AC-1
0.36 W AC-3eFront cover With mounting support Rail
Platestandards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1product certifications BV
GOST
CSA
RINA
LROS (Lloyds register of shipping)
DNV
UL
GL
CCC
UKCAconnections – terminals Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endtightening torque Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2operating time 12…22 ms closing
4…19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 15 Mcycles maximum operating rate 3600 cyc/h 60 °C coil technology Without built-in suppressor module control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hzinrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 2…3 W at 50/60 Hz auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25…400 Hz minimum switching current 5 mA for signalling circuit minimum switching voltage 17 V for signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuit IP degree of protection IP20 front face conforming to IEC 60529 protective treatment TH conforming to IEC 60068-2-30 pollution degree 3 ambient air temperature for operation -40…60 °C
60…70 °C with deratingambient air temperature for storage -60…80 °C operating altitude 0…3000 m fire resistance 850 °C conforming to IEC 60695-2-1 mechanical robustness Vibrations contactor open: 2 Gn, 5…300 Hz
Vibrations contactor closed: 4 Gn, 5…300 Hz
Shocks contactor open: 10 Gn for 11 ms
Shocks contactor closed: 15 Gn for 11 msheight 77 mm width 45 mm depth 86 mm net weight 0.325 kg
LC1D18BD
Coil Voltage | 24 V dc |
Number of Poles | 3 |
Contact Current Rating | 18 A |
Power Rating | 7.5 kW |
Normal State Configuration | 3NO |
Contact Voltage Rating | 690 V ac |
Series | LC1D |
Range | TeSys D |
Number Of Auxiliary Contacts | 2 |
Terminal Type | Screw |
Width | 45mm |
Depth | 93mm |
Maximum Operating Temperature | +60°C |
Minimum Operating Temperature | -5°C |
Length | 77mm |