LADN04
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D LC1D
TeSys D CAD
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 4 NC Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL 60947-5-1
600 V conforming to CSA C22.2 No 60947-5-1[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5product certifications IECEE CB Scheme
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
Screw clamp terminals 2 cable(s) 1…2.5 mm²rigidtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2colour Dark grey height 48 mm width 44 mm depth 42 mm net weight 0.05 kg environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN11
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 1 NO + 1 NC Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL 60947-5-1
600 V conforming to CSA C22.2 No 60947-5-1[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5product certifications IECEE CB Scheme
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
Screw clamp terminals 2 cable(s) 1…2.5 mm²rigidtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2colour Dark grey height 48 mm width 26 mm depth 42 mm environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN20
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 2 NO Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL
600 V conforming to CSA[Ith] conventional free air thermal current 10 A (at 60 °C) standards UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5
EN 50012product certifications CB
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable endtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2
1.7 N.m – with screwdriver pozidriv No 2colour Dark grey height 48 mm width 26 mm depth 42 mm environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN22
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 2 NO + 2 NC Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL 60947-5-1
600 V conforming to CSA C22.2 No 60947-5-1[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5product certifications IECEE CB Scheme
UL
CSA
CCC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
Screw clamp terminals 2 cable(s) 1…2.5 mm²rigidtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2colour Dark grey height 48 mm width 44 mm depth 42 mm net weight 0.05 kg environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN31
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 3 NO + 1 NC Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ie] rated operational current 6 A at 120 V AC-15
1.04 A at 690 V AC-15
0.55 A at 125 V DC-13
0.1 A at 600 V DC-13[Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL 60947-5-1
600 V conforming to CSA C22.2 No 60947-5-1[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5product certifications IECEE CB Scheme
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…2.5 mm²rigid
Screw clamp terminals 2 cable(s) 1…2.5 mm²rigidtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2colour Dark grey height 48 mm width 44 mm depth 42 mm net weight 0.05 kg environmental characteristic Normal environment IP degree of protection IP20 conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m
LADN40
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Auxiliary contact block device short name LADN range compatibility TeSys D CAD
TeSys D LC1D
TeSys F LC1F
TeSys F CR1F
TeSys Deca CAD
TeSys Deca LC1Dmounting location Front pole contact composition 4 NO Contacts operation Instantaneous [Ue] rated operational voltage 690 V AC 25…400 Hz [Ui] rated insulation voltage 690 V conforming to IEC 60947-5-1
600 V conforming to UL
600 V conforming to CSA[Ith] conventional free air thermal current 10 A (at 60 °C) standards EN/IEC 60947-5-1
UL 60947-5-1
CSA C22.2 No 60947-5-1
GB/T 14048.5
EN 50012product certifications CB
UL
CSA
CCC
EAC
UKCAIrms rated making capacity 140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1permissible short-time rating 100 A 60 °C 1 s
120 A 60 °C 500 ms
140 A 60 °C 100 msprotection type GG fuse 10 A mechanical durability 30 Mcycles minimum switching current 5 mA minimum switching voltage 17 V non-overlap time 1.5 ms on de-energisation no overlap between NC and NO contact
1.5 ms on energisation no overlap between NC and NO contactinsulation resistance > 10 MOhm connections – terminals Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 1…4 mm²rigid without cable end
Screw clamp terminals 2 cable(s) 1…4 mm²rigid without cable endtightening torque 1.7 N.m – with screwdriver flat Ø 6 mm
1.7 N.m – with screwdriver Philips No 2
1.7 N.m – with screwdriver pozidriv No 2colour Dark grey height 48 mm width 44 mm depth 42 mm net weight 0.05 kg environmental characteristic Normal environment IP degree of protection IP2x conforming to IEC 60529 protective treatment TH conforming to IEC 60068 ambient air temperature for storage -60…80 °C ambient air temperature for operation -5…60 °C operating altitude 3000 m Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 60.8 g Package 1 Height 4.2 cm Package 1 width 5 cm Package 1 Length 5 cm Unit Type of Package 2 P06 Number of Units in Package 2 1280 Package 2 Weight 89.614 kg Package 2 Height 75 cm Package 2 width 80 cm Package 2 Length 60 cm Unit Type of Package 3 S03 Number of Units in Package 3 160 Package 3 Weight 10.202 kg Package 3 Height 30 cm Package 3 width 30 cm Package 3 Length 40 cm
LC1D09BD
Coil Voltage | 24 V dc |
Number of Poles | 3 |
Contact Current Rating | 9 A |
Power Rating | 4 kW |
Normal State Configuration | 3NO |
Contact Voltage Rating | 690 V ac |
Series | LC1D |
Range | TeSys D |
Number Of Auxiliary Contacts | 2 |
Terminal Type | Screw |
Width | 45mm |
Depth | 93mm |
Minimum Operating Temperature | -5°C |
Length | 77mm |
Maximum Operating Temperature | +60°C |
LC1D12M7
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Contactor device short name LC1D contactor application Resistive load
Motor controlutilisation category AC-4
AC-1
AC-3
AC-3epoles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC[Ie] rated operational current 25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
12 A (at <60 °C) at <= 440 V AC AC-3e for power circuitmotor power kW 3 kW at 220…230 V AC 50/60 Hz (AC-3)
5.5 kW at 380…400 V AC 50/60 Hz (AC-3)
5.5 kW at 415…440 V AC 50/60 Hz (AC-3)
7.5 kW at 500 V AC 50/60 Hz (AC-3)
7.5 kW at 660…690 V AC 50/60 Hz (AC-3)
3.7 kW at 400 V AC 50/60 Hz (AC-4)
3 kW at 220…230 V AC 50/60 Hz (AC-3e)
5.5 kW at 380…400 V AC 50/60 Hz (AC-3e)
5.5 kW at 415…440 V AC 50/60 Hz (AC-3e)
7.5 kW at 500 V AC 50/60 Hz (AC-3e)
7.5 kW at 660…690 V AC 50/60 Hz (AC-3e)motor power HP (UL / CSA) 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
2 hp at 230/240 V AC 50/60 Hz for 1 phase motors
3 hp at 200/208 V AC 50/60 Hz for 3 phases motors
3 hp at 230/240 V AC 50/60 Hz for 3 phases motors
7.5 hp at 460/480 V AC 50/60 Hz for 3 phases motors
10 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit type AC at 50/60 Hz [Uc] control circuit voltage 220 V AC 50/60 Hz auxiliary contact composition 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 overvoltage category III [Ith] conventional free air thermal current 25 A (at 60 °C) for power circuit
10 A (at 60 °C) for signalling circuitIrms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current 105 A 40 °C – 10 s for power circuit
210 A 40 °C – 1 s for power circuit
30 A 40 °C – 10 min for power circuit
61 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V coordination type 1 for power circuit
25 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 2.5 mOhm – Ith 25 A 50 Hz for power circuit [Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certifiedelectrical durability 2 Mcycles 12 A AC-3 at Ue <= 440 V
0.8 Mcycles 25 A AC-1 at Ue <= 440 V
2 Mcycles 12 A AC-3e at Ue <= 440 Vpower dissipation per pole 0.36 W AC-3
1.56 W AC-1
0.36 W AC-3eFront cover With mounting support Rail
Platestandards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1product certifications BV
GOST
CSA
RINA
LROS (Lloyds register of shipping)
DNV
UL
GL
CCC
UKCAconnections – terminals Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable endtightening torque Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver Philips No 2
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2operating time 12…22 ms closing
4…19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 15 Mcycles maximum operating rate 3600 cyc/h 60 °C coil technology Without built-in suppressor module control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hzinrush power in VA 70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 2…3 W at 50/60 Hz auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25…400 Hz minimum switching current 5 mA for signalling circuit minimum switching voltage 17 V for signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuit IP degree of protection IP20 front face conforming to IEC 60529 protective treatment TH conforming to IEC 60068-2-30 pollution degree 3 ambient air temperature for operation -40…60 °C
60…70 °C with deratingambient air temperature for storage -60…80 °C operating altitude 0…3000 m fire resistance 850 °C conforming to IEC 60695-2-1 mechanical robustness Vibrations contactor open: 2 Gn, 5…300 Hz
Vibrations contactor closed: 4 Gn, 5…300 Hz
Shocks contactor open: 10 Gn for 11 ms
Shocks contactor closed: 15 Gn for 11 msheight 77 mm width 45 mm depth 86 mm net weight 0.325 kg
LC1D18BD
Coil Voltage | 24 V dc |
Number of Poles | 3 |
Contact Current Rating | 18 A |
Power Rating | 7.5 kW |
Normal State Configuration | 3NO |
Contact Voltage Rating | 690 V ac |
Series | LC1D |
Range | TeSys D |
Number Of Auxiliary Contacts | 2 |
Terminal Type | Screw |
Width | 45mm |
Depth | 93mm |
Maximum Operating Temperature | +60°C |
Minimum Operating Temperature | -5°C |
Length | 77mm |
LC1D25BD
Coil Voltage | 24 V dc |
Number of Poles | 3 |
Contact Current Rating | 25 A |
Power Rating | 11 kW |
Normal State Configuration | 3NO |
Contact Voltage Rating | 690 V ac |
Series | LC1D |
Range | TeSys D |
Number Of Auxiliary Contacts | 2 |
Terminal Type | Screw |
Width | 45mm |
Depth | 99mm |
Maximum Operating Temperature | +60°C |
Length | 85mm |
Minimum Operating Temperature | -40°C |
LC1D65AM7
range TeSys
TeSys Decaproduct name TeSys D
TeSys Decaproduct or component type Contactor device short name LC1D contactor application Motor control
Resistive loadutilisation category AC-4
AC-1
AC-3
AC-3epoles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC[Ie] rated operational current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
65 A (at <60 °C) at <= 440 V AC AC-3e for power circuitmotor power kW 11 kW at 400 V AC 50/60 Hz (AC-4)
18.5 kW at 220…230 V AC 50/60 Hz (AC-3)
30 kW at 380…400 V AC 50/60 Hz (AC-3)
37 kW at 500 V AC 50/60 Hz (AC-3)
37 kW at 660…690 V AC 50/60 Hz (AC-3)
18.5 kW at 220…230 V AC 50/60 Hz (AC-3e)
30 kW at 380…400 V AC 50/60 Hz (AC-3e)
37 kW at 500 V AC 50/60 Hz (AC-3e)
37 kW at 660…690 V AC 50/60 Hz (AC-3e)motor power HP (UL / CSA) 40 hp at 460/480 V AC 50/60 Hz for 3 phases motors
5 hp at 115 V AC 50/60 Hz for 1 phase motors
10 hp at 230/240 V AC 50/60 Hz for 1 phase motors
20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
20 hp at 230/240 V AC 50/60 Hz for 3 phases motors
50 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit type AC at 50/60 Hz [Uc] control circuit voltage 220 V AC 50/60 Hz auxiliary contact composition 1 NO + 1 NC [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947 overvoltage category III [Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
80 A (at 60 °C) for power circuitIrms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
1000 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current 520 A 40 °C – 10 s for power circuit
900 A 40 °C – 1 s for power circuit
110 A 40 °C – 10 min for power circuit
260 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
125 A gG at <= 690 V coordination type 1 for power circuit
125 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 1.5 mOhm – Ith 80 A 50 Hz for power circuit [Ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1electrical durability 1.4 Mcycles 80 A AC-1 at Ue <= 440 V
1.45 Mcycles 65 A AC-3 at Ue <= 440 V
1.45 Mcycles 65 A AC-3e at Ue <= 440 Vpower dissipation per pole 9.6 W AC-1
6.3 W AC-3
6.3 W AC-3eFront cover With mounting support Rail
Platestandards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
IEC 60335-1product certifications UL
CCC
GOST
CSAconnections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible without cable end
Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible without cable end
Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²flexible with cable end
Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²flexible with cable end
Power circuit: EverLink BTR screw connectors 1 cable(s) 1…35 mm²solid without cable end
Power circuit: EverLink BTR screw connectors 2 cable(s) 1…25 mm²solid without cable endtightening torque Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver Philips No 2
Power circuit: 8 N.m – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal screw head 4 mm
Power circuit: 5 N.m – on EverLink BTR screw connectors – cable 1…25 mm² hexagonal screw head 4 mm
Control circuit: 1.7 N.m – on EverLink BTR screw connectors – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on EverLink BTR screw connectors – with screwdriver pozidriv No 2
– on EverLink BTR screw connectorsoperating time 4…19 ms opening
12…26 ms closingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 6 Mcycles maximum operating rate 3600 cyc/h 60 °C coil technology Without built-in suppressor module control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hzinrush power in VA 140 VA 60 Hz cos phi 0.75 (at 20 °C)
160 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C)
15 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation 4…5 W at 50/60 Hz auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25…400 Hz minimum switching current 5 mA for signalling circuit minimum switching voltage 17 V for signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuit IP degree of protection IP20 front face conforming to IEC 60529 climatic withstand Conforming to IACS E10
conforming to IEC 60947-1 Annex Q category Dprotective treatment TH conforming to IEC 60068-2-30 pollution degree 3 ambient air temperature for operation -40…60 °C
60…70 °C with deratingambient air temperature for storage -60…80 °C operating altitude 0…3000 m fire resistance 850 °C conforming to IEC 60695-2-1 mechanical robustness Vibrations contactor open: 2 Gn, 5…300 Hz
Vibrations contactor closed: 4 Gn, 5…300 Hz
Shocks contactor closed: 15 Gn for 11 ms
Shocks contactor open: 10 Gn for 11 msheight 122 mm width 55 mm depth 120 mm net weight 0.86 kg
LC1D80AM7
oil Voltage | 220 V ac |
Number of Poles | 3 |
Contact Current Rating | 66 A |
Power Rating | 37 kW |
Normal State Configuration | 1NC + 1NO |
Range | TeSys |
Function | Reversing |
LC1D95M5
range TeSys product name TeSys D
TeSys Decaproduct or component type Contactor device short name LC1D contactor application Resistive load
Motor controlutilisation category AC-1
AC-4
AC-3
AC-3epoles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: 1000 V AC 25…400 Hz [Ie] rated operational current 95 A (at <60 °C) at <= 440 V AC-3 for power circuit
125 A (at <60 °C) at <= 690 V AC-1 for power circuit
95 A (at <60 °C) at <= 440 V AC-3e for power circuitmotor power kW 25 kW at 220…230 V AC 50 Hz (AC-3)
45 kW at 380…400 V AC 50 Hz (AC-3)
45 kW at 415…440 V AC 50 Hz (AC-3)
55 kW at 500 V AC 50 Hz (AC-3)
45 kW at 660…690 V AC 50 Hz (AC-3)
45 kW at 1000 V AC 50 Hz (AC-3)motor power HP (UL / CSA) 7.5 hp at 120 V AC 60 Hz for 1 phase motors
15 hp at 230/240 V AC 60 Hz for 1 phase motors
30 hp at 200/208 V AC 60 Hz for 3 phases motors
30 hp at 230/240 V AC 60 Hz for 3 phases motors
60 hp at 460/480 V AC 60 Hz for 3 phases motors
60 hp at 575/600 V AC 60 Hz for 3 phases motorscontrol circuit type AC at 50 Hz [Uc] control circuit voltage 220 V AC 50 Hz auxiliary contact composition 1 NO + 1 NC [Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947 overvoltage category III [Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit
125 A (at 60 °C) for power circuitIrms rated making capacity 1100 A at 440 V AC for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 1100 A at 440 V for power circuit conforming to IEC 60947 [Icw] rated short-time withstand current 1100 A 40 °C – 1 s for power circuit
800 A 40 °C – 10 s for power circuit
400 A 40 °C – 1 min for power circuit
135 A 40 °C – 10 min for power circuit
140 A – 100 ms for signalling circuit
120 A – 500 ms for signalling circuit
100 A – 1 s for signalling circuitassociated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuitaverage impedance 0.8 mOhm – Ith 125 A 50 Hz for power circuit [Ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certifiedelectrical durability 1.2 Mcycles 95 A AC-3
1.3 Mcycles 125 A AC-1
1.2 Mcycles 95 A AC-3epower dissipation per pole 12.5 W AC-1
7.2 W AC-3
7.2 W AC-3eFront cover With mounting support Plate
Railstandards EN/IEC 60947-1
EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4product certifications IECEE CB Scheme
UL
CSA
CCC
EAC
LROS (Lloyds register of shipping)
RINA
BV
DNV-GLconnections – terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: connector 1 cable(s) 4…50 mm²flexible without cable end
Power circuit: connector 2 cable(s) 4…25 mm²flexible without cable end
Power circuit: connector 1 cable(s) 4…50 mm²flexible with cable end
Power circuit: connector 2 cable(s) 4…16 mm²flexible with cable end
Power circuit: connector 1 cable(s) 4…50 mm²solid without cable end
Power circuit: connector 2 cable(s) 4…25 mm²solid without cable endtightening torque Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2
Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm
Power circuit: 12 N.m – on connector hexagonal screw head 4 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver pozidriv No 2operating time 20…35 ms closing
6…20 ms openingsafety reliability level B10d = 1.3 Mcycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 10 Mcycles maximum operating rate 3600 cyc/h 60 °C coil technology Without built-in suppressor module control circuit voltage limits 0.3…0.6 Uc (-40…70 °C):drop-out AC 50 Hz
0.85…1.1 Uc (-40…55 °C):operational AC 50 Hz
1…1.1 Uc (55…70 °C):operational AC 50 Hzinrush power in VA 200 VA 50 Hz cos phi 0.75 (at 20 °C) hold-in power consumption in VA 20 VA 50 Hz cos phi 0.3 (at 20 °C) heat dissipation 6…10 W at 50 Hz auxiliary contacts type Type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency 25…400 Hz minimum switching current 5 mA for signalling circuit minimum switching voltage 17 V for signalling circuit non-overlap time 1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contactinsulation resistance > 10 MOhm for signalling circuit IP degree of protection IP20 front face conforming to IEC 60529 climatic withstand Conforming to IACS E10 protective treatment TH conforming to IEC 60068-2-30 pollution degree 3 ambient air temperature for operation -40…60 °C
60…70 °C with deratingambient air temperature for storage -60…80 °C operating altitude 0…3000 m fire resistance 850 °C conforming to IEC 60695-2-1 mechanical robustness Vibrations contactor open: 2 Gn, 5…300 Hz
Shocks contactor open: 8 Gn for 11 ms
Vibrations contactor closed: 3 Gn, 5…300 Hz
Shocks contactor closed: 10 Gn for 11 msheight 127 mm width 85 mm depth 130 mm net weight 1.61 kg
LC1DFKM7
range TeSys
TeSys Decaproduct name TeSys LC1D.K
TeSys Decaproduct or component type Capacitor duty contactor device short name LC1DFK device application Control contactor application Power factor correction utilisation category AC-6b poles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz reactive power rating 7 kvar at 230 V AC 50 Hz 60 °C
12.5 kvar at 400 V AC 50 Hz 60 °C
13 kvar at 440 V AC 50 Hz 60 °C
21 kvar at 690 V AC 50 Hz 60 °Ccontrol circuit type AC at 50/60 Hz [Uc] control circuit voltage 220 V AC 50/60 Hz auxiliary contact composition 1 NO + 2 NC instantaneous electrical durability 300000 cycles at Ue 400 V
200000 cycles at Ue 690 Vmounting support DIN rail
Platestandards EN/IEC 60947-1
EN/IEC 60947-4-1
IEC 60335-1product certifications IECEE CB Scheme
UKCAconnections – terminals Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: solid
Power circuit: screw clamp terminals 2 1.5…4 mm² – cable stiffness: solid
Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1.5…6 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1.5…4 mm² – cable stiffness: flexible with cable endtightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 1.7 N.m – on screw clamp terminalsmaximum operating rate 240 cyc/h auxiliary contacts type Type mechanically linked 1 NO + 2 NC conforming to IEC 60947-5-1 IP degree of protection IP20 front face conforming to IEC 60529 ambient air temperature for operation -5…60 °C ambient air temperature for storage -60…80 °C operating altitude 0…3000 m height 115 mm width 45 mm depth 121 mm net weight 0.53 kg
LC1DGKM7
range TeSys
TeSys Decaproduct name TeSys LC1D.K
TeSys Decaproduct or component type Capacitor duty contactor device short name LC1DGK device application Control contactor application Power factor correction utilisation category AC-6b poles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz reactive power rating 9.5 kvar at 230 V AC 50 Hz 60 °C
16.7 kvar at 400 V AC 50 Hz 60 °C
18 kvar at 440 V AC 50 Hz 60 °C
28.5 kvar at 690 V AC 50 Hz 60 °Ccontrol circuit type AC at 50/60 Hz [Uc] control circuit voltage 220 V AC 50/60 Hz auxiliary contact composition 1 NO + 2 NC instantaneous electrical durability 300000 cycles at Ue 400 V
200000 cycles at Ue 690 Vmounting support DIN rail
Platestandards EN/IEC 60947-1
EN/IEC 60947-4-1
IEC 60335-1product certifications IECEE CB Scheme
UKCAconnections – terminals Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…16 mm² – cable stiffness: solid
Power circuit: screw clamp terminals 2 2.5…6 mm² – cable stiffness: solid
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable endtightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 2.5 N.m – on screw clamp terminalsmaximum operating rate 240 cyc/h auxiliary contacts type Type mechanically linked 1 NO + 2 NC conforming to IEC 60947-5-1 IP degree of protection IP20 front face conforming to IEC 60529 ambient air temperature for operation -5…60 °C ambient air temperature for storage -60…80 °C operating altitude 0…3000 m height 125 mm width 45 mm depth 127 mm net weight 0.6 kg
LC1DMKM7
range TeSys
TeSys Decaproduct name TeSys LC1D.K
TeSys Decaproduct or component type Capacitor duty contactor device short name LC1DMK device application Control contactor application Power factor correction utilisation category AC-6b poles description 3P power pole contact composition 3 NO device location in system Line interruption
Inside delta interruption[Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz reactive power rating 14 kvar at 230 V AC 50 Hz 60 °C
25 kvar at 400 V AC 50 Hz 60 °C
27 kvar at 440 V AC 50 Hz 60 °C
42 kvar at 690 V AC 50 Hz 60 °Ccontrol circuit type AC at 50/60 Hz [Uc] control circuit voltage 220 V AC 50/60 Hz auxiliary contact composition 1 NO + 2 NC instantaneous electrical durability 300000 cycles at Ue 400 V
200000 cycles at Ue 690 Vmounting support DIN rail
Platestandards EN/IEC 60947-1
EN/IEC 60947-4-1
IEC 60335-1product certifications IECEE CB Scheme
UKCAconnections – terminals Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…16 mm² – cable stiffness: solid
Power circuit: screw clamp terminals 2 2.5…6 mm² – cable stiffness: solid
Power circuit: screw clamp terminals 1 1.5…10 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 1.5…6 mm² – cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 1 1…10 mm² – cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible with cable endtightening torque Control circuit: 1.7 N.m – on screw clamp terminals
Power circuit: 2.5 N.m – on screw clamp terminalsmaximum operating rate 240 cyc/h auxiliary contacts type Type mechanically linked 1 NO + 2 NC conforming to IEC 60947-5-1 IP degree of protection IP20 front face conforming to IEC 60529 ambient air temperature for operation -5…60 °C ambient air temperature for storage -60…80 °C operating altitude 0…3000 m height 125 mm width 45 mm depth 127 mm net weight 0.63 kg
LC1DWK12M7
range TeSys product name TeSys LC1D.K product or component type Capacitor duty contactor device short name LC1DWK device application Control contactor application Power factor correction utilisation category AC-6b poles description 3P power pole contact composition 3 NO [Ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz reactive power rating 35 kvar at 230 V AC 50 Hz 60 °C
63 kvar at 400 V AC 50 Hz 60 °C
67 kvar at 440 V AC 50 Hz 60 °C
104 kvar at 690 V AC 50 Hz 60 °C
30 kvar at 230 V AC 60 Hz 60 °C
60 kvar at 460 V AC 60 Hz 60 °C
80 kvar at 575 V AC 60 Hz 60 °Ccontrol circuit type AC at 50/60 Hz [Uc] control circuit voltage 220 V AC 50/60 Hz auxiliary contact composition 1 NO + 2 NC instantaneous electrical durability 300000 cycles at Ue 400 V
200000 cycles at Ue 690 Vmounting support DIN rail
Platestandards EN/IEC 60947-1
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1product certifications IECEE CB Scheme
UL
CSA
UKCAconnections – terminals Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: solid
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 2 1…4 mm² – cable stiffness: flexible without cable end
Control circuit: screw clamp terminals 1 1…4 mm² – cable stiffness: flexible with cable end
Control circuit: screw clamp terminals 2 1…2.5 mm² – cable stiffness: flexible with cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: solid
Power circuit: connector 2 4…25 mm² – cable stiffness: solid
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible without cable end
Power circuit: connector 2 4…25 mm² – cable stiffness: flexible without cable end
Power circuit: connector 1 4…50 mm² – cable stiffness: flexible with cable end
Power circuit: connector 2 4…16 mm² – cable stiffness: flexible with cable endtightening torque Power circuit: 9 N.m – on connector
Control circuit: 1.7 N.m – on screw clamp terminalsmaximum operating rate 240 cyc/h auxiliary contacts type Type mechanically linked 1 NO + 2 NC conforming to IEC 60947-5-1 IP degree of protection IP20 front face conforming to IEC 60529 ambient air temperature for operation -5…60 °C ambient air temperature for storage -60…80 °C operating altitude 0…3000 m height 180 mm width 85 mm depth 154 mm net weight 1.65 kg Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Weight 1.721 kg Package 1 Height 13 cm Package 1 width 17 cm Package 1 Length 19 cm Unit Type of Package 2 P06 Number of Units in Package 2 48 Package 2 Weight 90.608 kg Package 2 Height 75 cm Package 2 width 80 cm Package 2 Length 60 cm
LC1F115M7
range of product
Easy Altivar 610
product or component type
Variable speed drive
product specific application
Fan, pump, compressor, conveyor
device short name
ATV610
variant
Standard version
product destination
Asynchronous motors
mounting mode
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
IP20
type of cooling
Forced convection
supply frequency
50…60 Hz +/-5 %
network number of phases
3 phases
[Us] rated supply voltage
380…460 V – 15…10 %
motor power kW
110 kW for normal duty
90 kW for heavy duty
motor power hp
150 hp for normal duty
125 hp for heavy duty
line current
201 A at 380 V (normal duty)
175.7 A at 460 V (normal duty)
170 A at 380 V (heavy duty)
149.1 A at 460 V (heavy duty)
prospective line Isc
50 kA
apparent power
140.0 kVA at 460 V (normal duty)
118.8 kVA at 460 V (heavy duty)
continuous output current
211 A at 2.5 kHz for normal duty
173 A at 2.5 kHz for heavy duty
maximum transient current
232 A during 60 s (normal duty)
260 A during 60 s (heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
output frequency
0.0001…0.5 kHz
nominal switching frequency
2.5 kHz
switching frequency
1…8 kHz adjustable
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
option card
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
output voltage
<= power supply voltage
motor slip compensation
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 50…3 x 120 mm²
Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type
1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
320 mm
height
852 mm
1159 mm with IP21 conformity kit
depth
390 mm
net weight
82 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number
6
discrete input type
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility
DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm
LC1F185M5
range of product
Easy Altivar 610
product or component type
Variable speed drive
product specific application
Fan, pump, compressor, conveyor
device short name
ATV610
variant
Standard version
product destination
Asynchronous motors
mounting mode
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
IP20
type of cooling
Forced convection
supply frequency
50…60 Hz +/-5 %
network number of phases
3 phases
[Us] rated supply voltage
380…460 V – 15…10 %
motor power kW
110 kW for normal duty
90 kW for heavy duty
motor power hp
150 hp for normal duty
125 hp for heavy duty
line current
201 A at 380 V (normal duty)
175.7 A at 460 V (normal duty)
170 A at 380 V (heavy duty)
149.1 A at 460 V (heavy duty)
prospective line Isc
50 kA
apparent power
140.0 kVA at 460 V (normal duty)
118.8 kVA at 460 V (heavy duty)
continuous output current
211 A at 2.5 kHz for normal duty
173 A at 2.5 kHz for heavy duty
maximum transient current
232 A during 60 s (normal duty)
260 A during 60 s (heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
output frequency
0.0001…0.5 kHz
nominal switching frequency
2.5 kHz
switching frequency
1…8 kHz adjustable
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
option card
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
output voltage
<= power supply voltage
motor slip compensation
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 50…3 x 120 mm²
Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type
1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
320 mm
height
852 mm
1159 mm with IP21 conformity kit
depth
390 mm
net weight
82 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number
6
discrete input type
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility
DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm
LC1F265M7
range of product
Easy Altivar 610
product or component type
Variable speed drive
product specific application
Fan, pump, compressor, conveyor
device short name
ATV610
variant
Standard version
product destination
Asynchronous motors
mounting mode
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
IP20
type of cooling
Forced convection
supply frequency
50…60 Hz +/-5 %
network number of phases
3 phases
[Us] rated supply voltage
380…460 V – 15…10 %
motor power kW
110 kW for normal duty
90 kW for heavy duty
motor power hp
150 hp for normal duty
125 hp for heavy duty
line current
201 A at 380 V (normal duty)
175.7 A at 460 V (normal duty)
170 A at 380 V (heavy duty)
149.1 A at 460 V (heavy duty)
prospective line Isc
50 kA
apparent power
140.0 kVA at 460 V (normal duty)
118.8 kVA at 460 V (heavy duty)
continuous output current
211 A at 2.5 kHz for normal duty
173 A at 2.5 kHz for heavy duty
maximum transient current
232 A during 60 s (normal duty)
260 A during 60 s (heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
output frequency
0.0001…0.5 kHz
nominal switching frequency
2.5 kHz
switching frequency
1…8 kHz adjustable
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
option card
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
output voltage
<= power supply voltage
motor slip compensation
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 50…3 x 120 mm²
Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type
1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
320 mm
height
852 mm
1159 mm with IP21 conformity kit
depth
390 mm
net weight
82 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number
6
discrete input type
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility
DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm
LC1F330M7
range of product
Easy Altivar 610
product or component type
Variable speed drive
product specific application
Fan, pump, compressor, conveyor
device short name
ATV610
variant
Standard version
product destination
Asynchronous motors
mounting mode
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
IP20
type of cooling
Forced convection
supply frequency
50…60 Hz +/-5 %
network number of phases
3 phases
[Us] rated supply voltage
380…460 V – 15…10 %
motor power kW
110 kW for normal duty
90 kW for heavy duty
motor power hp
150 hp for normal duty
125 hp for heavy duty
line current
201 A at 380 V (normal duty)
175.7 A at 460 V (normal duty)
170 A at 380 V (heavy duty)
149.1 A at 460 V (heavy duty)
prospective line Isc
50 kA
apparent power
140.0 kVA at 460 V (normal duty)
118.8 kVA at 460 V (heavy duty)
continuous output current
211 A at 2.5 kHz for normal duty
173 A at 2.5 kHz for heavy duty
maximum transient current
232 A during 60 s (normal duty)
260 A during 60 s (heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
output frequency
0.0001…0.5 kHz
nominal switching frequency
2.5 kHz
switching frequency
1…8 kHz adjustable
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
option card
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
output voltage
<= power supply voltage
motor slip compensation
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 50…3 x 120 mm²
Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type
1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
320 mm
height
852 mm
1159 mm with IP21 conformity kit
depth
390 mm
net weight
82 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number
6
discrete input type
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility
DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm
LC1F400M7
range of product
Easy Altivar 610
product or component type
Variable speed drive
product specific application
Fan, pump, compressor, conveyor
device short name
ATV610
variant
Standard version
product destination
Asynchronous motors
mounting mode
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
IP20
type of cooling
Forced convection
supply frequency
50…60 Hz +/-5 %
network number of phases
3 phases
[Us] rated supply voltage
380…460 V – 15…10 %
motor power kW
110 kW for normal duty
90 kW for heavy duty
motor power hp
150 hp for normal duty
125 hp for heavy duty
line current
201 A at 380 V (normal duty)
175.7 A at 460 V (normal duty)
170 A at 380 V (heavy duty)
149.1 A at 460 V (heavy duty)
prospective line Isc
50 kA
apparent power
140.0 kVA at 460 V (normal duty)
118.8 kVA at 460 V (heavy duty)
continuous output current
211 A at 2.5 kHz for normal duty
173 A at 2.5 kHz for heavy duty
maximum transient current
232 A during 60 s (normal duty)
260 A during 60 s (heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
output frequency
0.0001…0.5 kHz
nominal switching frequency
2.5 kHz
switching frequency
1…8 kHz adjustable
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
option card
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
output voltage
<= power supply voltage
motor slip compensation
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 50…3 x 120 mm²
Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type
1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
320 mm
height
852 mm
1159 mm with IP21 conformity kit
depth
390 mm
net weight
82 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number
6
discrete input type
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility
DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm
LC1F500M7
range of product
Easy Altivar 610
product or component type
Variable speed drive
product specific application
Fan, pump, compressor, conveyor
device short name
ATV610
variant
Standard version
product destination
Asynchronous motors
mounting mode
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
IP20
type of cooling
Forced convection
supply frequency
50…60 Hz +/-5 %
network number of phases
3 phases
[Us] rated supply voltage
380…460 V – 15…10 %
motor power kW
110 kW for normal duty
90 kW for heavy duty
motor power hp
150 hp for normal duty
125 hp for heavy duty
line current
201 A at 380 V (normal duty)
175.7 A at 460 V (normal duty)
170 A at 380 V (heavy duty)
149.1 A at 460 V (heavy duty)
prospective line Isc
50 kA
apparent power
140.0 kVA at 460 V (normal duty)
118.8 kVA at 460 V (heavy duty)
continuous output current
211 A at 2.5 kHz for normal duty
173 A at 2.5 kHz for heavy duty
maximum transient current
232 A during 60 s (normal duty)
260 A during 60 s (heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
output frequency
0.0001…0.5 kHz
nominal switching frequency
2.5 kHz
switching frequency
1…8 kHz adjustable
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
option card
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
output voltage
<= power supply voltage
motor slip compensation
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 50…3 x 120 mm²
Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type
1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
320 mm
height
852 mm
1159 mm with IP21 conformity kit
depth
390 mm
net weight
82 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number
6
discrete input type
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility
DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm
LC1F630M7
range of product
Easy Altivar 610
product or component type
Variable speed drive
product specific application
Fan, pump, compressor, conveyor
device short name
ATV610
variant
Standard version
product destination
Asynchronous motors
mounting mode
Cabinet mount
EMC filter
Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection
IP20
type of cooling
Forced convection
supply frequency
50…60 Hz +/-5 %
network number of phases
3 phases
[Us] rated supply voltage
380…460 V – 15…10 %
motor power kW
110 kW for normal duty
90 kW for heavy duty
motor power hp
150 hp for normal duty
125 hp for heavy duty
line current
201 A at 380 V (normal duty)
175.7 A at 460 V (normal duty)
170 A at 380 V (heavy duty)
149.1 A at 460 V (heavy duty)
prospective line Isc
50 kA
apparent power
140.0 kVA at 460 V (normal duty)
118.8 kVA at 460 V (heavy duty)
continuous output current
211 A at 2.5 kHz for normal duty
173 A at 2.5 kHz for heavy duty
maximum transient current
232 A during 60 s (normal duty)
260 A during 60 s (heavy duty)
asynchronous motor control profile
Variable torque standard
Optimized torque mode
Constant torque standard
output frequency
0.0001…0.5 kHz
nominal switching frequency
2.5 kHz
switching frequency
1…8 kHz adjustable
number of preset speeds
16 preset speeds
communication port protocol
Modbus serial
option card
Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card
output voltage
<= power supply voltage
motor slip compensation
Can be suppressed
Adjustable
Not available in permanent magnet motor law
Automatic whatever the load
acceleration and deceleration ramps
Linear adjustable separately from 0.01 to 9000 s
S, U or customized
braking to standstill
By DC injection
protection type
Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control, screw terminal: 0.5…1.5 mm²
Line side, screw terminal: 2 x 50…3 x 120 mm²
Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type
1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling
2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
320 mm
height
852 mm
1159 mm with IP21 conformity kit
depth
390 mm
net weight
82 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number
6
discrete input type
DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility
DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic
Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number
2
analogue output type
Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input
5 ms +/- 1 ms (DI5, DI6)configurable – pulse input
10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
noise level
76 dB conforming to 86/188/EEC
power dissipation in W
2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position
Vertical +/- 10 degree
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree
2 conforming to EN/IEC 61800-5-1
vibration resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance
6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation
-15…45 °C (without derating)
45…60 °C (with derating factor)
operating altitude
<= 1000 m without derating
1000…4800 m with current derating 1 % per 100 m
environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Weight
96.344 kg
Package 1 Height
47 cm
Package 1 width
67 cm
Package 1 Length
103 cm