A9R11480
Range Acti9 Product name Acti9 iID Product or component type Residual current circuit breaker (RCCB) Device short name IID Poles description 4P Neutral position Left [In] rated current 80 A Network type AC Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 1500 A
Im 1500 ARated conditional short-circuit current 10 kA [Ui] rated insulation voltage 500 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 6 kV Surge current 250 A Contact position indicator Yes Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 91 mm Width 72 mm Depth 73.5 mm Net weight 0.37 kg Colour White Mechanical durability 20000 cycles Electrical durability AC-1: 10000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferruleWire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1 Product certifications SNI IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 8.2 cm Package 1 Width 7.5 cm Package 1 Length 10 cm Package 1 Weight 399 g Unit Type of Package 2 S03 Number of Units in Package 2 27 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 11.387 kg
A9R11491
range | Acti 9 |
---|---|
product name | Acti9 iID |
product or component type | Residual current circuit breaker (RCCB) |
device short name | IID |
poles description | 4P |
neutral position | Left |
[In] rated current | 100 A |
network type | AC |
earth-leakage sensitivity | 30 mA |
earth-leakage protection time delay | Instantaneous |
earth-leakage protection class | Type AC |
device location in system | Outgoer |
---|---|
network frequency | 50/60 Hz |
[Ue] rated operational voltage | 380…415 V AC 50/60 Hz |
residual current tripping technology | Voltage independent |
rated breaking and making capacity | Idm 1500 A Im 1500 A |
rated conditional short-circuit current | 10 kA |
[Ui] rated insulation voltage | 500 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 6 kV |
surge current | 250 A |
contact position indicator | Yes |
control type | Toggle |
mounting mode | Clip-on |
mounting support | DIN rail |
9 mm pitches | 8 |
height | 91 mm |
width | 72 mm |
depth | 73.5 mm |
net weight | 0.37 kg |
colour | White |
mechanical durability | 20000 cycles |
electrical durability | AC-1: 10000 cycles |
locking options description | Padlocking device |
connections – terminals | Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule |
wire stripping length | 14 mm for top or bottom connection |
tightening torque | 3.5 N.m top or bottom |
standards | EN/IEC 61008-1 |
---|---|
product certifications | ISI SNI |
IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
pollution degree | 3 |
electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 |
ambient air temperature for operation | -5…60 °C |
ambient air temperature for storage | -40…85 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 411.0 g |
Package 1 Height | 8.2 cm |
Package 1 width | 7.5 cm |
Package 1 Length | 10 cm |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 27 |
Package 2 Weight | 11.552 kg |
Package 2 Height | 30 cm |
Package 2 width | 30 cm |
Package 2 Length | 40 cm |
A9R14491
Range Acti9 Product name Acti9 iID Product or component type Residual current circuit breaker (RCCB) Device short name IID Poles description 4P Neutral position Left [In] rated current 100 A Network type AC Earth-leakage sensitivity 300 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 1500 A
Im 1500 ARated conditional short-circuit current 10 kA [Ui] rated insulation voltage 500 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 6 kV Contact position indicator Yes Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 91 mm Width 72 mm Depth 73.5 mm Net weight 0.37 kg Colour White Mechanical durability 20000 cycles Electrical durability AC-1: 10000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferruleWire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1 Product certifications SNI IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.5 cm Package 1 Width 8.5 cm Package 1 Length 10 cm Package 1 Weight 356 g Unit Type of Package 2 S03 Number of Units in Package 2 27 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 10.224 kg
A9R41425
Range Acti9 Product name Acti9 iID Product or component type Residual current circuit breaker (RCCB) Device short name IID Poles description 4P Neutral position Left [In] rated current 25 A Network type AC Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 1500 A
Im 1500 ARated conditional short-circuit current 10 kA [Ui] rated insulation voltage 500 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 6 kV Surge current 250 A Contact position indicator Yes Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 91 mm Width 72 mm Depth 73.5 mm Net weight 0.37 kg Colour White Mechanical durability 20000 cycles Electrical durability AC-1: 15000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferruleWire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1
EN/IEC 61008-2-1IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 8.5 cm Package 1 Width 7.5 cm Package 1 Length 10.0 cm Package 1 Weight 358.0 g Unit Type of Package 2 S03 Number of Units in Package 2 27 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 10.226 kg
A9R41440
Range Acti9 Product name Acti9 iID Product or component type Residual current circuit breaker (RCCB) Device short name IID Poles description 4P Neutral position Left [In] rated current 40 A Network type AC Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 1500 A
Im 1500 ARated conditional short-circuit current 10 kA [Ui] rated insulation voltage 500 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 6 kV Surge current 250 A Contact position indicator Yes Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 91 mm Width 72 mm Depth 73.5 mm Net weight 0.37 kg Colour White Mechanical durability 20000 cycles Electrical durability AC-1: 15000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferruleWire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1
EN/IEC 61008-2-1IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.6 cm Package 1 Width 8.5 cm Package 1 Length 10.0 cm Package 1 Weight 360.0 g Unit Type of Package 2 S03 Number of Units in Package 2 27 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 10.228 kg
A9R41463
Range Acti9 Product name Acti9 iID Product or component type Residual current circuit breaker (RCCB) Device short name IID Poles description 4P Neutral position Left [In] rated current 63 A Network type AC Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 1500 A
Im 1500 ARated conditional short-circuit current 10 kA [Ui] rated insulation voltage 500 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 6 kV Surge current 250 A Contact position indicator Yes Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 91 mm Width 72 mm Depth 73.5 mm Net weight 0.37 kg Colour White Mechanical durability 20000 cycles Electrical durability AC-1: 15000 cycles Locking options description Padlocking device Connections – terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferruleWire stripping length 14 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1
EN/IEC 61008-2-1IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 3 Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 8.5 cm Package 1 Width 7.6 cm Package 1 Length 10.0 cm Package 1 Weight 411.0 g Unit Type of Package 2 S03 Number of Units in Package 2 27 Package 2 Height 30.0 cm Package 2 Width 30.0 cm Package 2 Length 40.0 cm Package 2 Weight 11.537 kg
A9R44463
range | Acti 9 |
---|---|
product name | Acti9 iID |
product or component type | Residual current circuit breaker (RCCB) |
device short name | IID |
poles description | 4P |
neutral position | Left |
[In] rated current | 63 A |
network type | AC |
earth-leakage sensitivity | 300 mA |
earth-leakage protection time delay | Instantaneous |
earth-leakage protection class | Type AC |
device location in system | Outgoer |
---|---|
network frequency | 50/60 Hz |
[Ue] rated operational voltage | 380…415 V AC 50/60 Hz |
residual current tripping technology | Voltage independent |
rated breaking and making capacity | Idm 1500 A Im 1500 A |
rated conditional short-circuit current | 10 kA |
[Ui] rated insulation voltage | 500 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 6 kV |
surge current | 250 A |
contact position indicator | Yes |
control type | Toggle |
mounting mode | Clip-on |
mounting support | DIN rail |
9 mm pitches | 8 |
height | 91 mm |
width | 72 mm |
depth | 73.5 mm |
net weight | 0.37 kg |
colour | White |
mechanical durability | 20000 cycles |
electrical durability | AC-1: 15000 cycles |
locking options description | Padlocking device |
connections – terminals | Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule |
wire stripping length | 14 mm for top or bottom connection |
tightening torque | 3.5 N.m top or bottom |
standards | EN/IEC 61008-1 |
---|---|
IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
pollution degree | 3 |
electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 |
ambient air temperature for operation | -5…60 °C |
ambient air temperature for storage | -40…85 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 350.0 g |
Package 1 Height | 7.6 cm |
Package 1 width | 8.5 cm |
Package 1 Length | 10 cm |
Unit Type of Package 2 | S03 |
Number of Units in Package 2 | 27 |
Package 2 Weight | 10.027 kg |
Package 2 Height | 30 cm |
Package 2 width | 30 cm |
Package 2 Length | 40 cm |
A9R50425
Range Acti9 Product name Acti9 iID K Product or component type Residual current circuit breaker (RCCB) Device short name IID K Poles description 4P Neutral position Left [In] rated current 25 A Network type AC Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Quality labels VDE Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 500 A
Im 500 ARated conditional short-circuit current GL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA[Ui] rated insulation voltage 440 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 4 kV Surge current 250 A Contact position indicator No Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 85 mm Width 72 mm Depth 69 mm Net weight 0.37 kg Colour White Mechanical durability 5000 cycles Electrical durability AC-1: 2000 cycles Locking options description Padlocking device Connections – terminals Tunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferruleWire stripping length 16 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1
EN/IEC 61008-2-1IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 2 Electromagnetic compatibility 8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.5 cm Package 1 Width 8.5 cm Package 1 Length 10 cm Package 1 Weight 357 g Unit Type of Package 2 S03 Number of Units in Package 2 27 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 10.257 kg Unit Type of Package 3 P12 Number of Units in Package 3 216 Package 3 Height 50 cm Package 3 Width 80 cm Package 3 Length 120 cm Package 3 Weight 93.008 kg
A9R50440
Range Acti9 Product name Acti9 iID K Product or component type Residual current circuit breaker (RCCB) Device short name IID K Poles description 4P Neutral position Left [In] rated current 40 A Network type AC Earth-leakage sensitivity 30 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Quality labels VDE Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 500 A
Im 500 ARated conditional short-circuit current GL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA[Ui] rated insulation voltage 440 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 4 kV Surge current 250 A Contact position indicator No Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 85 mm Width 72 mm Depth 69 mm Net weight 0.37 kg Colour White Mechanical durability 5000 cycles Electrical durability AC-1: 2000 cycles Locking options description Padlocking device Connections – terminals Tunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferruleWire stripping length 16 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1
EN/IEC 61008-2-1IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 2 Electromagnetic compatibility 8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 8 cm Package 1 Width 7.5 cm Package 1 Length 10 cm Package 1 Weight 351 g Unit Type of Package 2 S03 Number of Units in Package 2 27 Package 2 Height 30 cm Package 2 Width 30 cm Package 2 Length 40 cm Package 2 Weight 10.993 kg Unit Type of Package 3 P12 Number of Units in Package 3 216 Package 3 Height 75 cm Package 3 Width 60 cm Package 3 Length 80 cm Package 3 Weight 95.944 kg
A9R75425
Range Acti9 Product name Acti9 iID K Product or component type Residual current circuit breaker (RCCB) Device short name IID K Poles description 4P Neutral position Left [In] rated current 25 A Network type AC Earth-leakage sensitivity 300 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Quality labels VDE Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 500 A
Im 500 ARated conditional short-circuit current GL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA[Ui] rated insulation voltage 440 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 4 kV Surge current 250 A Contact position indicator No Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 85 mm Width 72 mm Depth 69 mm Net weight 0.37 kg Colour White Mechanical durability 5000 cycles Electrical durability AC-1: 2000 cycles Locking options description Padlocking device Connections – terminals Tunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferruleWire stripping length 16 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1
EN/IEC 61008-2-1IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 2 Electromagnetic compatibility 8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.5 cm Package 1 Width 8.5 cm Package 1 Length 10 cm Package 1 Weight 352 g Unit Type of Package 2 BB1 Number of Units in Package 2 3 Package 2 Height 9 cm Package 2 Width 10.5 cm Package 2 Length 25.5 cm Package 2 Weight 1.152 kg Unit Type of Package 3 S03 Number of Units in Package 3 27 Package 3 Height 30 cm Package 3 Width 30 cm Package 3 Length 40 cm Package 3 Weight 11.028 kg
A9R75440
Range Acti9 Product name Acti9 iID K Product or component type Residual current circuit breaker (RCCB) Device short name IID K Poles description 4P Neutral position Left [In] rated current 40 A Network type AC Earth-leakage sensitivity 300 mA Earth-leakage protection time delay Instantaneous Earth-leakage protection class Type AC Quality labels VDE Device location in system Outgoer Network frequency 50/60 Hz [Ue] rated operational voltage 380…415 V AC 50/60 Hz residual current tripping technology Voltage independent Rated breaking and making capacity Idm 500 A
Im 500 ARated conditional short-circuit current GL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA[Ui] rated insulation voltage 440 V AC 50/60 Hz [Uimp] rated impulse withstand voltage 4 kV Surge current 250 A Contact position indicator No Control type Toggle Mounting mode Clip-on Mounting support DIN rail 9 mm pitches 8 Height 85 mm Width 72 mm Depth 69 mm Net weight 0.37 kg Colour White Mechanical durability 5000 cycles Electrical durability AC-1: 2000 cycles Locking options description Padlocking device Connections – terminals Tunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferruleWire stripping length 16 mm for top or bottom connection Tightening torque 3.5 N.m top or bottom Standards EN/IEC 61008-1
EN/IEC 61008-2-1IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529Pollution degree 2 Electromagnetic compatibility 8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1 Ambient air temperature for operation -5…60 °C Ambient air temperature for storage -40…85 °C Unit Type of Package 1 PCE Number of Units in Package 1 1 Package 1 Height 7.5 cm Package 1 Width 8.2 cm Package 1 Length 10 cm Package 1 Weight 352 g Unit Type of Package 2 BB1 Number of Units in Package 2 3 Package 2 Height 9 cm Package 2 Width 10.7 cm Package 2 Length 25.5 cm Package 2 Weight 1.147 kg Unit Type of Package 3 S03 Number of Units in Package 3 27 Package 3 Height 30 cm Package 3 Width 30 cm Package 3 Length 40 cm Package 3 Weight 11.08 kg