محافظ جان تک فاز

فیلترها

دسته‌بندی را انتخاب کنید

A9A26924

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4 cm
Package 1 Width8 cm
Package 1 Length10 cm
Package 1 Weight210 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.781 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight106.248 kg

A9R41225

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4 cm
Package 1 Width8 cm
Package 1 Length10 cm
Package 1 Weight210 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.781 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight106.248 kg

A9R41240

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current40 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.5 cm
Package 1 Length9.6 cm
Package 1 Weight209 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.727 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight105.816 kg

A9R41263

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current63 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

A9R44263

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current63 A
Network typeAC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4 cm
Package 1 Width8 cm
Package 1 Length10 cm
Package 1 Weight211 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.835 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight106.680 kg

A9R50225

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4 cm
Package 1 Width8 cm
Package 1 Length10 cm
Package 1 Weight210 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.781 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight106.248 kg

A9R75225

RangeActi9
Product nameActi9 iID K
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID K
Poles description2P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Quality labelsVDE
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 500 A
Im 500 A
Rated conditional short-circuit currentGL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Contact position indicatorNo
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height85 mm
Width36 mm
Depth69 mm
Net weight0.21 kg
ColourWhite
Mechanical durability5000 cycles
Electrical durabilityAC-1: 2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Electromagnetic compatibility8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.1 cm
Package 1 Width8.2 cm
Package 1 Length10 cm
Package 1 Weight202 g
Unit Type of Package 2BB1
Number of Units in Package 26
Package 2 Height10.5 cm
Package 2 Width9.5 cm
Package 2 Length25.5 cm
Package 2 Weight1.307 kg
Unit Type of Package 3S03
Number of Units in Package 354
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight12.409 kg

A9R75240

RangeActi9
Product nameActi9 iID K
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID K
Poles description2P
Neutral positionLeft
[In] rated current40 A
Network typeAC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 500 A
Im 500 A
Rated conditional short-circuit currentGL63: Inc 4.5 kA
K60: Inc 6 kA
C60: Inc 6 kA
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Surge current250 A
Contact position indicatorNo
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height85 mm
Width36 mm
Depth69 mm
Net weight0.21 kg
ColourWhite
Mechanical durability5000 cycles
Electrical durabilityAC-1: 2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminals top or bottom 1…35 mm² rigid
Tunnel type terminals top or bottom 1…25 mm² flexible
Tunnel type terminals top or bottom 1…25 mm² flexible with ferrule
Wire stripping length16 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree2
Electromagnetic compatibility8/20 µs impulse withstand, 200 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.5 cm
Package 1 Width4 cm
Package 1 Length10 cm
Package 1 Weight202 g
Unit Type of Package 2BB1
Number of Units in Package 26
Package 2 Height10.5 cm
Package 2 Width9 cm
Package 2 Length25.5 cm
Package 2 Weight1.311 kg
Unit Type of Package 3S03
Number of Units in Package 354
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight12.03 kg

M9R11225

RangeMulti9
Product nameMulti9 ID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameID
Device applicationDistribution
Poles description2P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 250 A conforming to EN/IEC 61008-1
Rated conditional short-circuit currentInc 10 kA
[Ui] rated insulation voltage440 V AC 50 Hz conforming to EN/IEC 61008-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 61008-1
Surge current250 A
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height81 mm
Width36 mm
Depth73 mm
Net weight0.23 kg
ColourGrey
Mechanical durability20000 cycles
Electrical durability2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminal (top or bottom) 1…35 mm² – rigid
Tunnel type terminal (top or bottom) 1…25 mm² – flexible
Tunnel type terminal (top or bottom) 3 cable(s) 16 mm² – rigid
Tunnel type terminal (top or bottom) 3 cable(s) 10 mm² – flexible
Tunnel type terminal (top or bottom) 1…25 mm² – flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
Product certificationsCE
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…40 °C
Ambient air temperature for storage-40…60 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.5 cm
Package 1 Length8.7 cm
Package 1 Weight205 g
Unit Type of Package 2S03
Number of Units in Package 236
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight7.821 kg
Unit Type of Package 3P12
Number of Units in Package 3288
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight74.568 kg

M9R11240

RangeMulti9
Product nameMulti9 ID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameID
Device applicationDistribution
Poles description2P
Neutral positionLeft
[In] rated current40 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 400 A conforming to EN/IEC 61008-1
Rated conditional short-circuit currentInc 10 kA
[Ui] rated insulation voltage440 V AC 50 Hz conforming to EN/IEC 61008-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 61008-1
Surge current250 A
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height81 mm
Width36 mm
Depth73 mm
Net weight0.23 kg
ColourGrey
Mechanical durability20000 cycles
Electrical durability2000 cycles
Locking options descriptionPadlocking device
Connections – terminalsTunnel type terminal (top or bottom) 1…35 mm² – rigid
Tunnel type terminal (top or bottom) 1…25 mm² – flexible
Tunnel type terminal (top or bottom) 3 cable(s) 16 mm² – rigid
Tunnel type terminal (top or bottom) 3 cable(s) 10 mm² – flexible
Tunnel type terminal (top or bottom) 1…25 mm² – flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
Product certificationsCE
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…40 °C
Ambient air temperature for storage-40…60 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.5 cm
Package 1 Length9.0 cm
Package 1 Weight205 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.511 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight104.088 kg
فروشگاه
مقايسه
حساب من