A9A26924

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4 cm
Package 1 Width8 cm
Package 1 Length10 cm
Package 1 Weight210 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.781 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight106.248 kg

A9D31606

RangeActi9
Product nameActi9 iDPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameIDPN N Vigi
Device applicationDistribution
Poles description1P + N
Number of protected poles1
Neutral positionLeft
[In] rated current6 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Suitability for isolationYes conforming to EN/IEC 60947-2
ComplementaryOutgoer
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
Magnetic tripping limit5…10 x In
residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage400 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch9 mm between phase and neutral
9 mm pitches4
Height85 mm
Width36 mm
Depth73 mm
Net weight125 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability20000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
Product certificationsVDE
GOST
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.5 cm
Package 1 Length10.0 cm
Package 1 Weight208 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.673 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight105.384 kg

A9D31610

RangeActi9
Product nameActi9 iDPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameIDPN N Vigi
Device applicationDistribution
Poles description1P + N
Number of protected poles1
Neutral positionLeft
[In] rated current10 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Suitability for isolationYes conforming to EN/IEC 60947-2
ComplementaryOutgoer
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
Magnetic tripping limit5…10 x In
residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage400 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch9 mm between phase and neutral
9 mm pitches4
Height85 mm
Width36 mm
Depth73 mm
Net weight125 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability20000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
Product certificationsVDE
GOST
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.5 cm
Package 1 Length10.0 cm
Package 1 Weight213 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.943 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight107.544 kg

A9D31616

RangeActi9
Product nameActi9 iDPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameIDPN N Vigi
Device applicationDistribution
Poles description1P + N
Number of protected poles1
Neutral positionLeft
[In] rated current16 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Suitability for isolationYes conforming to EN/IEC 60947-2
ComplementaryOutgoer
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
Magnetic tripping limit5…10 x In
residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage400 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch9 mm between phase and neutral
9 mm pitches4
Height85 mm
Width36 mm
Depth73 mm
Net weight125 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability20000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
Product certificationsVDE
GOST
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.0 cm
Package 1 Length10.0 cm
Package 1 Weight209 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.727 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight105.816 kg

A9D31625

RangeActi9
Product nameActi9 iDPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameIDPN N Vigi
Device applicationDistribution
Poles description1P + N
Number of protected poles1
Neutral positionLeft
[In] rated current25 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Suitability for isolationYes conforming to EN/IEC 60947-2
Device location in systemOutgoer
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
Magnetic tripping limit5…10 x In
residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage400 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch9 mm between phase and neutral
9 mm pitches4
Height85 mm
Width36 mm
Depth73 mm
Net weight125 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
Product certificationsVDE
GOST
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.0 cm
Package 1 Length10.0 cm
Package 1 Weight209 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.727 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight105.816 kg

A9D31632

RangeActi9
Product nameActi9 iDPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameIDPN N Vigi
Device applicationDistribution
Poles description1P + N
Number of protected poles1
Neutral positionLeft
[In] rated current32 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Suitability for isolationYes conforming to EN/IEC 60947-2
Device location in systemOutgoer
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
Magnetic tripping limit5…10 x In
residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage400 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch9 mm between phase and neutral
9 mm pitches4
Height85 mm
Width36 mm
Depth73 mm
Net weight125 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
Product certificationsVDE
GOST
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4 cm
Package 1 Width8.5 cm
Package 1 Length10 cm
Package 1 Weight224 g
Unit Type of Package 2BB1
Number of Units in Package 26
Package 2 Height9 cm
Package 2 Width10.7 cm
Package 2 Length25.5 cm
Package 2 Weight1.406 kg
Unit Type of Package 3S03
Number of Units in Package 354
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight13.179 kg

A9D31640

RangeActi9
Product nameActi9 iDPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameIDPN N Vigi
Device applicationDistribution
Poles description1P + N
Number of protected poles1
Neutral positionLeft
[In] rated current40 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Suitability for isolationYes conforming to EN/IEC 60947-2
ComplementaryOutgoer
Network frequency50 Hz
[Ue] rated operational voltage220…240 V AC 50 Hz
Magnetic tripping limit5…10 x In
residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 220…240 V AC 50 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage400 V AC 50 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch9 mm between phase and neutral
9 mm pitches4
Height85 mm
Width36 mm
Depth73 mm
Net weight125 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…16 mm² rigid
Single terminal top or bottom 1…10 mm² flexible
Single terminal top or bottom 1…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
Product certificationsVDE
GOST
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity95 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.5 cm
Package 1 Length10.0 cm
Package 1 Weight226 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight12.645 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight113.160 kg

A9D31710

RangeActi9
Product nameActi9 DPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameDPN N Vigi
Device applicationDistribution
Poles description3P + N
Number of protected poles3
Neutral positionLeft
[In] rated current10 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Suitability for isolationYes conforming to EN/IEC 60947-2
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
Magnetic tripping limit5…10 x In
residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch18 mm between phases
9 mm between phase and neutral
9 mm pitches10
Height91 mm
Width90 mm
Depth78.5 mm
Net weight498 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability20000 cycles
Locking options descriptionPadlocking device
Sealable
Connections – terminalsTunnel type terminal top or bottom 0.75…16 mm² rigid
Tunnel type terminal top or bottom 0.33…10 mm² flexible
Tunnel type terminal top or bottom 0.33…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity90 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-30…70 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.9 cm
Package 1 Width11.3 cm
Package 1 Length16.2 cm
Package 1 Weight553 g

A9D31732

RangeActi9
Product nameActi9 DPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameDPN N Vigi
Device applicationDistribution
Poles description3P + N
Number of protected poles3
Neutral positionLeft
[In] rated current32 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Suitability for isolationYes conforming to EN/IEC 60947-2
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
Magnetic tripping limit5…10 x In
residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch18 mm between phases
9 mm between phase and neutral
9 mm pitches10
Height91 mm
Width90 mm
Depth78.5 mm
Net weight498 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Locking options descriptionPadlocking device
Sealable
Connections – terminalsTunnel type terminal top or bottom 0.75…16 mm² rigid
Tunnel type terminal top or bottom 0.33…10 mm² flexible
Tunnel type terminal top or bottom 0.33…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity90 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-30…70 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9 cm
Package 1 Width11 cm
Package 1 Length16 cm
Package 1 Weight578 g

A9D31740

RangeActi9
Product nameActi9 DPN Vigi
Product or component typeResidual current breaker with overcurrent protection (RCBO)
Device short nameDPN N Vigi
Device applicationDistribution
Poles description3P + N
Number of protected poles3
Neutral positionLeft
[In] rated current40 A
Network typeAC
Trip unit technologyThermal-magnetic
Curve codeC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Breaking capacity6000 A Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Suitability for isolationYes conforming to EN/IEC 60947-2
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
Magnetic tripping limit5…10 x In
residual current tripping technologyVoltage independent
[Ics] rated service breaking capacity6000 A 100 % x Icn at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Rated breaking and making capacityIdm 6000 A at 380…415 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Limitation class3 conforming to EN/IEC 61009-2-1
[Ui] rated insulation voltage440 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage4 kV
Contact position indicatorYes
Control typeToggle
Local signallingON, OFF, fault trip
Mounting modeClip-on
Mounting supportDIN rail
Comb busbar and distribution block compatibilityTop or bottom: YES
Connection pitch18 mm between phases
9 mm between phase and neutral
9 mm pitches10
Height91 mm
Width90 mm
Depth78.5 mm
Net weight498 g
ColourWhite
Mechanical durability20000 cycles
Electrical durability10000 cycles
Locking options descriptionPadlocking device
Sealable
Connections – terminalsTunnel type terminal top or bottom 0.75…16 mm² rigid
Tunnel type terminal top or bottom 0.33…10 mm² flexible
Tunnel type terminal top or bottom 0.33…10 mm² flexible with ferrule
Wire stripping length15 mm for top or bottom connection
Tightening torque2 N.m top or bottom
Earth-leakage protectionIntegrated
StandardsEN/IEC 61009-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Overvoltage categoryIII conforming to IEC 60364
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61009-2-1
Tropicalisation2 conforming to IEC 60068-1
Relative humidity90 % at 55 °C
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-30…70 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9 cm
Package 1 Width11 cm
Package 1 Length16 cm
Package 1 Weight585 g

A9R11480

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description4P
Neutral positionLeft
[In] rated current80 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches8
Height91 mm
Width72 mm
Depth73.5 mm
Net weight0.37 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 10000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
Product certificationsSNI
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.2 cm
Package 1 Width7.5 cm
Package 1 Length10 cm
Package 1 Weight399 g
Unit Type of Package 2S03
Number of Units in Package 227
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight11.387 kg

A9R11491

Main
range Acti 9
product name Acti9 iID
product or component type Residual current circuit breaker (RCCB)
device short name IID
poles description 4P
neutral position Left
[In] rated current 100 A
network type AC
earth-leakage sensitivity 30 mA
earth-leakage protection time delay Instantaneous
earth-leakage protection class Type AC
Complementary
device location in system Outgoer
network frequency 50/60 Hz
[Ue] rated operational voltage 380…415 V AC 50/60 Hz
residual current tripping technology Voltage independent
rated breaking and making capacity Idm 1500 A
Im 1500 A
rated conditional short-circuit current 10 kA
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 6 kV
surge current 250 A
contact position indicator Yes
control type Toggle
mounting mode Clip-on
mounting support DIN rail
9 mm pitches 8
height 91 mm
width 72 mm
depth 73.5 mm
net weight 0.37 kg
colour White
mechanical durability 20000 cycles
electrical durability AC-1: 10000 cycles
locking options description Padlocking device
connections – terminals Single terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
wire stripping length 14 mm for top or bottom connection
tightening torque 3.5 N.m top or bottom
Environment
standards EN/IEC 61008-1
product certifications ISI
SNI
IP degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
pollution degree 3
electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
ambient air temperature for operation -5…60 °C
ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 411.0 g
Package 1 Height 8.2 cm
Package 1 width 7.5 cm
Package 1 Length 10 cm
Unit Type of Package 2 S03
Number of Units in Package 2 27
Package 2 Weight 11.552 kg
Package 2 Height 30 cm
Package 2 width 30 cm
Package 2 Length 40 cm

A9R14491

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description4P
Neutral positionLeft
[In] rated current100 A
Network typeAC
Earth-leakage sensitivity300 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage380…415 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches8
Height91 mm
Width72 mm
Depth73.5 mm
Net weight0.37 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 10000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
Product certificationsSNI
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height7.5 cm
Package 1 Width8.5 cm
Package 1 Length10 cm
Package 1 Weight356 g
Unit Type of Package 2S03
Number of Units in Package 227
Package 2 Height30 cm
Package 2 Width30 cm
Package 2 Length40 cm
Package 2 Weight10.224 kg

A9R41225

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current25 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4 cm
Package 1 Width8 cm
Package 1 Length10 cm
Package 1 Weight210 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.781 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight106.248 kg

A9R41240

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current40 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
StandardsEN/IEC 61008-1
EN/IEC 61008-2-1
IP degree of protectionIP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
Pollution degree3
Electromagnetic compatibility8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation-5…60 °C
Ambient air temperature for storage-40…85 °C
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.0 cm
Package 1 Width8.5 cm
Package 1 Length9.6 cm
Package 1 Weight209 g
Unit Type of Package 2S03
Number of Units in Package 254
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight11.727 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height44.4 cm
Package 3 Width80 cm
Package 3 Length120 cm
Package 3 Weight105.816 kg

A9R41263

RangeActi9
Product nameActi9 iID
Product or component typeResidual current circuit breaker (RCCB)
Device short nameIID
Poles description2P
Neutral positionLeft
[In] rated current63 A
Network typeAC
Earth-leakage sensitivity30 mA
Earth-leakage protection time delayInstantaneous
Earth-leakage protection classType AC
Device location in systemOutgoer
Network frequency50/60 Hz
[Ue] rated operational voltage220…240 V AC 50/60 Hz
residual current tripping technologyVoltage independent
Rated breaking and making capacityIdm 1500 A
Im 1500 A
Rated conditional short-circuit current10 kA
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage6 kV
Surge current250 A
Contact position indicatorYes
Control typeToggle
Mounting modeClip-on
Mounting supportDIN rail
9 mm pitches4
Height91 mm
Width36 mm
Depth73.5 mm
Net weight0.21 kg
ColourWhite
Mechanical durability20000 cycles
Electrical durabilityAC-1: 15000 cycles
Locking options descriptionPadlocking device
Connections – terminalsSingle terminal top or bottom 1…35 mm² rigid
Single terminal top or bottom 1…25 mm² flexible
Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length14 mm for top or bottom connection
Tightening torque3.5 N.m top or bottom
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm