پاور میتر اشنایدر

فیلترها

دسته‌بندی را انتخاب کنید

METSEDM6200

Range of productPowerLogic
Device short nameDM6200
Product or component typeMultimeter
Device applicationEquipment monitoring
Power monitoring
Preventive maintenance
Type of measurementCurrent
Voltage
Frequency
Power factor
Phase unbalance
Phase angle
RPM
[Us] rated supply voltage44…277 V AC 50/60 Hz
44…277 V DC
Network frequency45…65 Hz
Maximum power consumption in VA3 VA at 240 V AC
Display typeLED indicator
Sampling rate20 samples/cycle
Measurement current5 A
1 A
Analogue input typeCurrent 0.05…6 A (impedance <= 0.1 Ohm)
Measurement voltage80…480 V AC phase to phase
Measurement accuracyFrequency 0.1 %
Power factor 1 %
Voltage 1 % 46…277 V
Current 1 % 0.05…6 A
Communication port protocolModbus
Communication port supportTerminal block: RS485
Transmission rate19.2 kbauds
Electromagnetic compatibilityElectrostatic discharge immunity test: , conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: , conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: , conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: , conforming to IEC 61000-4-5
Conducted RF disturbances: , conforming to IEC 61000-4-6
Immunity to impulse waves: , conforming to IEC 61000-4-12
Conducted and radiated emissions: , A, conforming to CISPR 11
Immunity to microbreaks and voltage drops: , conforming to IEC 61000-4-11
Mounting modeFlush-mounted
Type of installationIndoor installation
Overvoltage categoryIII
IP degree of protectionIP40 back:
IP51 front face:
Pollution degree2
Ambient air temperature for operation-10…60 °C
Ambient air temperature for storage-25…70 °C
Relative humidity95 %
Operating altitude0…2000 m
StandardsUL 508
IEC 61010
Product certificationsCE
Width96 mm
Depth80 mm
Height96 mm
Net weight0.4 kg
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11 cm
Package 1 Width12.5 cm
Package 1 Length12.8 cm
Package 1 Weight537 g

METSEPM1200

Range of productPowerLogic PM1000
Device short namePM1200
Product or component typePower meter
Power quality analysisUp to the 9th harmonic
Type of measurementCurrent
Voltage
Frequency
Active and reactive power
Active and reactive energy
Power factor
supply voltage44…277 V AC 50/60 Hz
44…277 V DC
Network frequency50/60 Hz
Maximum power consumption in VA3 VA at 240 V AC
Display typeLED
Display resolution3 lines with 4 digits
Sampling rate20 samples/cycle
Measurement current50…6000 mA
input typeCurrent 0…5 A (impedance <= 0.1 Ohm)
Current 0…1 A (impedance <= 0.1 Ohm)
Measurement voltage80…480 V AC 50/60 Hz phase to phase
0…999000 V AC 50/60 Hz with external VT
Measurement accuracyPower 1 %
Current 1 %
Voltage 1 %
Energy 1 %
Frequency 0.1 %
Power factor 1 %
Apparent power 1 %
Accuracy classClass 2 reactive energy conforming to IEC 62053-23
Class 1 active energy conforming to IEC 62053-21
Communication port protocolModbus 19.2 kbauds
Communication port supportRS485
Electromagnetic compatibilityImmunity to impulse waves: , conforming to IEC 61000-4-12
Electrostatic discharge immunity test: , conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: , conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: , conforming to IEC 61000-4-4
Conducted RF disturbances: , conforming to IEC 61000-4-6
1.2/50 µs shock waves immunity test: , conforming to IEC 61000-4-5
Immunity to microbreaks and voltage drops: , conforming to IEC 61000-4-11
Conducted and radiated emissions: , class A, conforming to CISPR 11
Mounting modeFlush-mounted
Mounting supportPanel
Type of installationIndoor installation
Overvoltage categoryIII
IP degree of protectionIP51 front face: conforming to IEC 60529
IP40 back: conforming to IEC 60529
Relative humidity5…95 %
Ambient air temperature for operation-10…60 °C
Ambient air temperature for storage-25…70 °C
Operating altitude0…2000 m
StandardsIEC 62053-21
IEC 62052-11
Width96 mm
Depth80 mm embedded:
Height96 mm
Net weight0.4 kg

METSEPM2120

  • Bill checking to verify that you are only charged for the energy you use
  • Aggregation of energy consumption and cost allocation within the same facility
  • Energy cost and usage analysis to optimise energy usage
  • Metering of electrical parameters to understand your electrical distribution system
RangeEasyLogic
Product nameEasyLogic PM2100
Device short namePM2120
Product or component typePower meter
Device applicationSub billing
Power monitoring
Power quality analysisTotal harmonic distortion
up to the 15th harmonic
Type of measurementApparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy total
Metering typeCurrent I, I1, I2, I3
Peak demand power PM, QM, SM
Active, reactive, apparent energy (signed, four quadrant)
Peak demand currents
Active power P, P1, P2, P3
Calculated neutral current
Voltage U, U21, U32, U13, V, V1, V2, V3
Unbalance current
Reactive power Q, Q1, Q2, Q3
Demand power P, Q, S
Apparent power S, S1, S2, S3
Accuracy classClass 1 active energy conforming to IEC 62053-21
Class 1 reactive energy conforming to IEC 62053-24
Class 5 harmonic distorsion (I THD & U THD)
Measurement accuracyApparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 1 %
Active power +/- 1 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current5…6000 mA
Measurement voltage35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range45…65 Hz
[Us] rated supply voltage44…277 V AC 45…65 Hz +/- 10 %
44…277 V DC +/- 10 %
Network frequency50 Hz
60 Hz
Ride-through time100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical
[In] rated current1 A
5 A
Maximum power consumption in VA6 VA at 277 V AC
Maximum power consumption in W3.3 W (power lines (AC))
2 W at 277 V (power lines (DC))
input impedanceCurrent (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settingsProtected by access code
Display type7 segments LED
Display colourRed
messages display capacity3 fields of 4 characters
Display digits12 digit(s) – 14.2 mm in height
Demand intervalsConfigurable from 1 to 60 min
Information displayedDemand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Control type3 x button
Local signallingRed LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communication
Number of inputs0
Number of outputs0
Communication port protocolModbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V
Communication port supportScrew terminal block: RS485
Data recordingTime stamping
Min/max for 8 parameters
Function availableReal time clock
Sampling rate64 samples/cycle
CybersecurityEnable/disable communication ports
Communication serviceRemote monitoring
Product certificationsCE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick
Mounting modeClip-on
Mounting positionVertical
Mounting supportFramework
Provided equipment1 x installation guide
Measurement categoryCategory III 480 V
Category II 480…600 V
Electrical insulation classDouble insulation
Class II
Flame retardanceV-0 conforming to UL 94
Connections – terminalsCurrent transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4
MaterialPolycarbonate
Width96 mm
Depth76.09 mm total:
61.64 mm embedded:
Height96 mm
Net weight300 g
Compatibility codePM2120
Service life7 year(s)
IP degree of protectionIP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity5…95 % at 50 °C
Pollution degree2
Ambient air temperature for operation-10…60 °C
Ambient air temperature for storage-25…70 °C
Operating altitude<= 2000 m
Electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class A
Overvoltage categoryIII
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height9.6 cm
Package 1 Width6.72 cm
Package 1 Length10.16 cm
Package 1 Weight302.5 g

METSEPM2130

RangeEasyLogic
Product nameEasyLogic PM2100
Device short namePM2130
Product or component typePower meter
Device applicationSub billing
Power monitoring
Power quality analysisTotal harmonic distortion
up to the 31st harmonic
Type of measurementApparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy total
Metering typePeak demand currents
Active power P, P1, P2, P3
Demand power P, Q, S
Reactive power Q, Q1, Q2, Q3
Apparent power S, S1, S2, S3
Active, reactive, apparent energy (signed, four quadrant)
Voltage U, U21, U32, U13, V, V1, V2, V3
Current I, I1, I2, I3
Calculated neutral current
Unbalance current
Peak demand power PM, QM, SM
Accuracy classClass 1 reactive energy conforming to IEC 62053-24
Class 0.5S active energy conforming to IEC 62053-22
Class 5 harmonic distorsion (I THD & U THD)
Measurement accuracyApparent power +/- 0.5 %
Active energy +/- 0.5 %
Reactive energy +/- 1 %
Active power +/- 0.5 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current5…6000 mA
Measurement voltage35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range45…65 Hz
[Us] rated supply voltage80…277 V AC 45…65 Hz +/- 10 %
100…277 V DC +/- 10 %
Network frequency50 Hz
60 Hz
Ride-through time50 ms 120 V AC typical
50 ms 230 V AC typical
50 ms 125 V DC typical
[In] rated current1 A
5 A
Maximum power consumption in VA8 VA at 277 V AC
Maximum power consumption in W3.3 W (power lines (AC))
3.3 W at 277 V (power lines (DC))
input impedanceCurrent (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settingsProtected by access code
Display type7 segments LED
Display colourRed
messages display capacity3 fields of 4 characters
Display digits12 digit(s) – 14.2 mm in height
Demand intervalsConfigurable from 1 to 60 min
Information displayedDemand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Control type3 x button
Local signallingRed LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communication
Number of inputs0
Number of outputs0
Communication port protocolModbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V
Communication port supportScrew terminal block: RS485
Data recordingPower logs
Time stamping
Energy consumption logs
Min/max for 8 parameters
Function availableReal time clock
Sampling rate64 samples/cycle
CybersecurityEnable/disable communication ports
Communication serviceRemote monitoring
Product certificationsCE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick
Mounting modeClip-on
Mounting positionVertical
Mounting supportFramework
Provided equipment1 x installation guide
Measurement categoryCategory III 480 V
Category II 480…600 V
Electrical insulation classClass II
Double insulation
Flame retardanceV-0 conforming to UL 94
Connections – terminalsCurrent transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4
MaterialPolycarbonate
Width96 mm
Depth76.09 mm total:
61.64 mm embedded:
Height96 mm
Net weight300 g
Compatibility codePM2130
Service life7 year(s)
IP degree of protectionIP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity5…95 % at 50 °C
Pollution degree2
Ambient air temperature for operation-10…60 °C
Ambient air temperature for storage-25…70 °C
Operating altitude<= 2000 m
Electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class A
Overvoltage categoryIII
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height11.5 cm
Package 1 Width8.7 cm
Package 1 Length12.0 cm
Package 1 Weight404.0 g
Unit Type of Package 2S03
Number of Units in Package 218
Package 2 Height30.0 cm
Package 2 Width30.0 cm
Package 2 Length40.0 cm
Package 2 Weight7.71 kg
Unit Type of Package 3P12
Number of Units in Package 3432
Package 3 Height80.0 cm
Package 3 Width80.0 cm
Package 3 Length120.0 cm
Package 3 Weight197.112 kg

METSEPM2220

  • Bill checking to verify that you are only charged for the energy you use
  • Aggregation of energy consumption and cost allocation within the same facility
  • Energy cost and usage analysis to optimise energy usage
  • Metering of electrical parameters to understand your electrical distribution system

 

RangeEasyLogic
Product nameEasyLogic PM2200
Device short namePM2220
Product or component typePower meter
Device applicationPower monitoring
Sub billing
Power quality analysisTotal harmonic distortion
up to the 15th harmonic
Type of measurementApparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy total
Metering typeActive, reactive, apparent energy (signed, four quadrant)
Current I, I1, I2, I3
Peak demand currents
Peak demand power PM, QM, SM
Unbalance current
Active power P, P1, P2, P3
Reactive power Q, Q1, Q2, Q3
Demand power P, Q, S
Voltage U, U21, U32, U13, V, V1, V2, V3
Apparent power S, S1, S2, S3
Calculated neutral current
Accuracy classClass 1 active energy conforming to IEC 62053-21
Class 1 reactive energy conforming to IEC 62053-24
Class 5 harmonic distorsion (I THD & U THD)
Measurement accuracyApparent power +/- 1 %
Active energy +/- 1 %
Reactive energy +/- 1 %
Active power +/- 1 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current5…6000 mA
Measurement voltage35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range45…65 Hz
[Us] rated supply voltage44…277 V AC 45…65 Hz +/- 10 %
44…277 V DC +/- 10 %
Network frequency50 Hz
60 Hz
Ride-through time100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical
[In] rated current1 A
5 A
Maximum power consumption in VA6 VA at 277 V AC
Maximum power consumption in W3.3 W (power lines (AC))
2 W at 277 V (power lines (DC))
input impedanceCurrent (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settingsProtected by access code
Display typeBacklit LCD
Display colourMonochrome
Display resolution128 x 128 pixels
Demand intervalsConfigurable from 1 to 60 min
Information displayedDemand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Harmonic amplitude
Control type4 x button
Local signallingRed LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communication
Number of inputs0
Number of outputs0
Communication port protocolModbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V
Communication port supportScrew terminal block: RS485
Data recordingTime stamping
Min/max for 8 parameters
Function availableReal time clock
Sampling rate64 samples/cycle
CybersecurityEnable/disable communication ports
Communication serviceRemote monitoring
languageSpanish
French
English
Russian
Portuguese
German
Chinese
Product certificationsCE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick
Mounting modeClip-on
Mounting positionVertical
Mounting supportFramework
Provided equipment1 x installation guide
Measurement categoryCategory III 480 V
Category II 480…600 V
Electrical insulation classDouble insulation
Class II
Flame retardanceV-0 conforming to UL 94
Connections – terminalsCurrent transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4
MaterialPolycarbonate
Width96 mm
Depth76.09 mm total:
61.64 mm embedded:
Height96 mm
Net weight300 g
Compatibility codePM2220
Service life7 year(s)
IP degree of protectionIP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
Relative humidity5…95 % at 50 °C
Pollution degree2
Ambient air temperature for operation-10…60 °C
Ambient air temperature for storage-25…70 °C
Operating altitude<= 2000 m
Electromagnetic compatibilityElectrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Emission tests conforming to FCC part 15 class A
Overvoltage categoryIII
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.9 cm
Package 1 Width12.2 cm
Package 1 Length11.7 cm
Package 1 Weight270 g

METSEPM2230

  • Bill checking to verify that you are only charged for the energy you use
  • Aggregation of energy consumption and cost allocation within the same facility
  • Energy cost and usage analysis to optimise energy usage
  • Metering of electrical parameters to understand your electrical distribution system

 

RangeEasyLogic
Product nameEasyLogic PM2200
Device short namePM2230
Product or component typePower meter
Device applicationPower monitoring
Sub billing
Power quality analysisTotal harmonic distortion
up to the 31st harmonic
Type of measurementApparent power min/max, total
Active and reactive power min/max, total
Current min/max, avg
Voltage min/max, avg
Frequency min/max, avg
Total current harmonic distortion THD (I) per phase
Total voltage harmonic distortion THD (U) per phase
Power factor min/max, avg
Apparent energy total
Active and reactive energy total
Metering typeCalculated neutral current
Active power P, P1, P2, P3
Current I, I1, I2, I3
Peak demand power PM, QM, SM
Voltage U, U21, U32, U13, V, V1, V2, V3
Peak demand currents
Reactive power Q, Q1, Q2, Q3
Demand power P, Q, S
Unbalance current
Active, reactive, apparent energy (signed, four quadrant)
Apparent power S, S1, S2, S3
Accuracy classClass 1 reactive energy conforming to IEC 62053-24
Class 0.5S active energy conforming to IEC 62053-22
Class 5 harmonic distorsion (I THD & U THD)
Measurement accuracyApparent power +/- 0.5 %
Active energy +/- 0.5 %
Reactive energy +/- 1 %
Active power +/- 0.5 %
Voltage +/- 0.5 %
Power factor +/- 0.01
Current +/- 0.5 %
Frequency +/- 0.05 %
Measurement current5…6000 mA
Measurement voltage35…480 V AC 50/60 Hz between phases
20…277 V AC 50/60 Hz between phase and neutral
480…999000 V AC 50/60 Hz with external VT
Frequency measurement range45…65 Hz
[Us] rated supply voltage80…277 V AC 45…65 Hz +/- 10 %
100…277 V DC +/- 10 %
Network frequency60 Hz
50 Hz
Ride-through time50 ms 120 V AC typical
50 ms 230 V AC typical
50 ms 125 V DC typical
[In] rated current5 A
1 A
Maximum power consumption in VA8 VA at 277 V AC
Maximum power consumption in W3.3 W (power lines (AC))
3.3 W at 277 V (power lines (DC))
input impedanceCurrent (impedance <= 0.3 mOhm)
Voltage (impedance > 5 MOhm)
Tamperproof of settingsProtected by access code
Display typeBacklit LCD
Display colourMonochrome
Display resolution128 x 128 pixels
Demand intervalsConfigurable from 1 to 60 min
Information displayedDemand current (past value)
Demand current (present value)
Demand power (past value)
Demand power (present value)
Voltage
Current
Frequency
Energy consumption
Harmonic distortion
Power factor
Active power
Apparent power
Reactive power
Unbalanced in %
Harmonic amplitude
Control type4 x button
Local signallingRed LED: output signal 1…9999000 pulse/ k_h (kWh, kVAh, kVARh)
Green LED: module operation and integrated communication
Number of inputs0
Number of outputs0
Communication port protocolModbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none – 2 wires, insulation 2500 V
Communication port supportScrew terminal block: RS485
Data recordingEnergy consumption logs
Power logs
Time stamping
Min/max for 8 parameters
Function availableReal time clock
Sampling rate64 samples/cycle
CybersecurityEnable/disable communication ports
Communication serviceRemote monitoring
languageRussian
French
Portuguese
English
Spanish
Chinese
German
Product certificationsCE conforming to IEC 61010-1
CULus conforming to UL 61010-1
CULus conforming to CSA C22.2 No 61010-1
RCM
EAC
C-Tick
Mounting modeClip-on
Mounting positionVertical
Mounting supportFramework
Provided equipment1 x installation guide
Measurement categoryCategory III 480 V
Category II 480…600 V
Electrical insulation classDouble insulation
Class II
Flame retardanceV-0 conforming to UL 94
Connections – terminalsCurrent transformer: screw connection (bottom) 6
Voltage inputs: screw connection (top) 4
MaterialPolycarbonate
Width96 mm
Depth76.09 mm total:
61.64 mm embedded:
Height96 mm
Net weight300 g
Compatibility codePM2230
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm
فروشگاه