شاسی اشنایدر

فیلترها

دسته‌بندی را انتخاب کنید

XB4BA21

range of product Easy Altivar 610
product or component type Variable speed drive
product specific application Fan, pump, compressor, conveyor
device short name ATV610
variant Standard version
product destination Asynchronous motors
mounting mode Cabinet mount
EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection IP20
type of cooling Forced convection
supply frequency 50…60 Hz +/-5 %
network number of phases 3 phases
[Us] rated supply voltage 380…460 V – 15…10 %
motor power kW 110 kW for normal duty 90 kW for heavy duty
motor power hp 150 hp for normal duty 125 hp for heavy duty
line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
prospective line Isc 50 kA
apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
output frequency 0.0001…0.5 kHz
nominal switching frequency 2.5 kHz
switching frequency 1…8 kHz adjustable
number of preset speeds 16 preset speeds
communication port protocol Modbus serial
option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
output voltage <= power supply voltage
motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
braking to standstill By DC injection
protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface 2-wire RS 485 for Modbus serial
transmission frame RTU for Modbus serial
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization No impedance for Modbus serial
number of addresses 1…247 for Modbus serial
method of access Slave
supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
width 320 mm
height 852 mm 1159 mm with IP21 conformity kit
depth 390 mm
net weight 82 kg
analogue input number 3
analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number 6
discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number 2
analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
relay output number 3
relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation Between power and control terminals
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

XB4BA22

range of product Easy Altivar 610
product or component type Variable speed drive
product specific application Fan, pump, compressor, conveyor
device short name ATV610
variant Standard version
product destination Asynchronous motors
mounting mode Cabinet mount
EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection IP20
type of cooling Forced convection
supply frequency 50…60 Hz +/-5 %
network number of phases 3 phases
[Us] rated supply voltage 380…460 V – 15…10 %
motor power kW 110 kW for normal duty 90 kW for heavy duty
motor power hp 150 hp for normal duty 125 hp for heavy duty
line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
prospective line Isc 50 kA
apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
output frequency 0.0001…0.5 kHz
nominal switching frequency 2.5 kHz
switching frequency 1…8 kHz adjustable
number of preset speeds 16 preset speeds
communication port protocol Modbus serial
option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
output voltage <= power supply voltage
motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
braking to standstill By DC injection
protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface 2-wire RS 485 for Modbus serial
transmission frame RTU for Modbus serial
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization No impedance for Modbus serial
number of addresses 1…247 for Modbus serial
method of access Slave
supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
width 320 mm
height 852 mm 1159 mm with IP21 conformity kit
depth 390 mm
net weight 82 kg
analogue input number 3
analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number 6
discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number 2
analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
relay output number 3
relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation Between power and control terminals
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

XB4BA31

  • Quick and easy assembly and disassembly
  • Robustness to withstand harsh environments
  • Various types of connection: screw clamp, connector, Faston connector or spring terminal
  • Excellent mechanical connection with operator head
  • A wide choice of contact blocks for general purposes or specific applications (low current, standard)

Range of productHarmony XB4
Product or component typePush-button
Device short nameXB4
Bezel materialChromium plated metal
Fixing collar materialZamak
Mounting diameter22 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatorSpring return
Operator profileGreen flush, unmarked
Head typeStandard
Contacts type and composition1 NO
Contact operationSlow-break
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1
Height47 mm
Width30 mm
Depth52 mm
Terminals description ISO n°1(13-14)NO
Net weight0.08 kg
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Contacts usageStandard contacts
Positive openingWithout
Operating travel2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Operating force3.8 N NO changing electrical state
Mechanical durability10000000 cycles
Tightening torque0.8…1.2 N.m conforming to EN 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4
Device presentationComplete product
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Overvoltage categoryClass I conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP67
IP69
IP69K
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK06 conforming to IEC 50102
StandardsJIS C8201-5-1
EN/IEC 60947-5-5
UL 508
EN/IEC 60947-1
EN/IEC 60947-5-4
EN/IEC 60947-5-1
CSA C22.2 No 14
JIS C8201-1
Product certificationsCSA
GL
BV
UL listed
DNV
LROS (Lloyds register of shipping)
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height3.500 cm
Package 1 Width5.500 cm
Package 1 Length8.500 cm
Package 1 Weight78.800 g
Unit Type of Package 2S03
Number of Units in Package 2150
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight12.257 kg
Unit Type of Package 3P06
Number of Units in Package 31200
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight106.056 kg

XB4BA3351

Range of productHarmony XB4
Product or component typePush-button
device short nameXB4
bezel materialChromium plated metal
Fixing collar materialZamak
Mounting diameter22 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatorSpring return
Operator profileBlack flush, down arrow (white)
Head typeStandard
contacts type and composition1 NO
contact operationSlow-break
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1
Net weight0.08 kg
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
contacts usageStandard contacts
Positive openingWithout
Operating travel2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Operating force3.8 N NO changing electrical state
Mechanical durability10000000 cycles
Tightening torque0.8…1.2 N.m conforming to EN 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4
device presentationComplete product
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Overvoltage categoryClass I conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP67
IP69
IP69K
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK06 conforming to IEC 50102
StandardsUL 508
EN/IEC 60947-1
EN/IEC 60947-5-5
EN/IEC 60947-5-4
CSA C22.2 No 14
EN/IEC 60947-5-1
JIS C8201-5-1
JIS C8201-1
product certificationsLROS (Lloyds register of shipping)
BV
CSA
GL
UL listed
DNV
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.800 cm
Package 1 Width3.400 cm
Package 1 Length5.400 cm
Package 1 Weight79.000 g
Unit Type of Package 2BB1
Number of Units in Package 25
Package 2 Height8.800 cm
Package 2 Width3.400 cm
Package 2 Length26.500 cm
Package 2 Weight397.000 g
Unit Type of Package 3S03
Number of Units in Package 3150
Package 3 Height30 cm
Package 3 Width30 cm
Package 3 Length40 cm
Package 3 Weight12.386 kg

XB4BA42

range of product Easy Altivar 610
product or component type Variable speed drive
product specific application Fan, pump, compressor, conveyor
device short name ATV610
variant Standard version
product destination Asynchronous motors
mounting mode Cabinet mount
EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection IP20
type of cooling Forced convection
supply frequency 50…60 Hz +/-5 %
network number of phases 3 phases
[Us] rated supply voltage 380…460 V – 15…10 %
motor power kW 110 kW for normal duty 90 kW for heavy duty
motor power hp 150 hp for normal duty 125 hp for heavy duty
line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
prospective line Isc 50 kA
apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
output frequency 0.0001…0.5 kHz
nominal switching frequency 2.5 kHz
switching frequency 1…8 kHz adjustable
number of preset speeds 16 preset speeds
communication port protocol Modbus serial
option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
output voltage <= power supply voltage
motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
braking to standstill By DC injection
protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface 2-wire RS 485 for Modbus serial
transmission frame RTU for Modbus serial
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization No impedance for Modbus serial
number of addresses 1…247 for Modbus serial
method of access Slave
supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
width 320 mm
height 852 mm 1159 mm with IP21 conformity kit
depth 390 mm
net weight 82 kg
analogue input number 3
analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number 6
discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number 2
analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
relay output number 3
relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation Between power and control terminals
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

XB4BA61

range of product Easy Altivar 610
product or component type Variable speed drive
product specific application Fan, pump, compressor, conveyor
device short name ATV610
variant Standard version
product destination Asynchronous motors
mounting mode Cabinet mount
EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection IP20
type of cooling Forced convection
supply frequency 50…60 Hz +/-5 %
network number of phases 3 phases
[Us] rated supply voltage 380…460 V – 15…10 %
motor power kW 110 kW for normal duty 90 kW for heavy duty
motor power hp 150 hp for normal duty 125 hp for heavy duty
line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
prospective line Isc 50 kA
apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
output frequency 0.0001…0.5 kHz
nominal switching frequency 2.5 kHz
switching frequency 1…8 kHz adjustable
number of preset speeds 16 preset speeds
communication port protocol Modbus serial
option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
output voltage <= power supply voltage
motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
braking to standstill By DC injection
protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface 2-wire RS 485 for Modbus serial
transmission frame RTU for Modbus serial
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization No impedance for Modbus serial
number of addresses 1…247 for Modbus serial
method of access Slave
supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
width 320 mm
height 852 mm 1159 mm with IP21 conformity kit
depth 390 mm
net weight 82 kg
analogue input number 3
analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number 6
discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number 2
analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
relay output number 3
relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation Between power and control terminals
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

XB4BACUST01

Range of productHarmony XB4
Product or component typePush-button
device short nameXB4
Bezel materialChromium plated metal
Fixing collar materialZamak
Mounting diameter22 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatorSpring return
Operator profileWhite flush, unmarked
Head typeStandard
Contacts type and composition1 NO
Contact operationSlow-break
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1
Height47 mm
Width30 mm
Depth52 mm
Terminals description ISO n°1(13-14)NO
Product weight0.08 kg
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Contacts usageStandard contacts
Positive openingWithout
Operating travel2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Operating force3.8 N NO changing electrical state
Mechanical durability10000000 cycles
Tightening torque0.8…1.2 N.m conforming to EN 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4
Device presentationComplete product
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Overvoltage categoryClass I conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP67
IP69
IP69K
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK06 conforming to IEC 50102
StandardsCSA C22.2 No 14
EN/IEC 60947-5-1
EN/IEC 60947-5-4
UL 508
EN/IEC 60947-5-5
EN/IEC 60947-1
JIS C8201-5-1
JIS C8201-1
Product certificationsBV
UL listed
CSA
GL
DNV
LROS (Lloyds register of shipping)
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height3.5 cm
Package 1 Width5.4 cm
Package 1 Length8.8 cm
Package 1 Weight79.0 g

XB4BD33

range of product Easy Altivar 610
product or component type Variable speed drive
product specific application Fan, pump, compressor, conveyor
device short name ATV610
variant Standard version
product destination Asynchronous motors
mounting mode Cabinet mount
EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection IP20
type of cooling Forced convection
supply frequency 50…60 Hz +/-5 %
network number of phases 3 phases
[Us] rated supply voltage 380…460 V – 15…10 %
motor power kW 110 kW for normal duty 90 kW for heavy duty
motor power hp 150 hp for normal duty 125 hp for heavy duty
line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
prospective line Isc 50 kA
apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
output frequency 0.0001…0.5 kHz
nominal switching frequency 2.5 kHz
switching frequency 1…8 kHz adjustable
number of preset speeds 16 preset speeds
communication port protocol Modbus serial
option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
output voltage <= power supply voltage
motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
braking to standstill By DC injection
protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface 2-wire RS 485 for Modbus serial
transmission frame RTU for Modbus serial
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization No impedance for Modbus serial
number of addresses 1…247 for Modbus serial
method of access Slave
supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
width 320 mm
height 852 mm 1159 mm with IP21 conformity kit
depth 390 mm
net weight 82 kg
analogue input number 3
analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number 6
discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number 2
analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
relay output number 3
relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation Between power and control terminals
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

XB4BS8442

Main
Range of productHarmony XB4
Product or component typeEmergency switching off push-button
Emergency stop push-button
Device short nameXB4
Bezel materialChromium plated metal
Fixing collar materialZamak
Mounting diameter22 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatorTrigger action and mechanical latching
Head typeStandard
resetTurn to release
Operator profileRed mushroom Ø 40 mm, unmarked
Contact operationSlow-break
Connections - terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1
Complementary
Height47 mm
Width40 mm
Depth82 mm
Terminals description ISO n°1(21-22)NC
Net weight0.118 kg
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Contacts usageStandard contacts
Positive openingWith conforming to EN/IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state)
4.3 mm (total travel)
Mechanical durability300000 cycles
Tightening torque0.8…1.2 N.m conforming to EN 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to EN 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5-4
Device presentationComplete product
Environment
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Electrical shock protection classClass I conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP67
IP69
IP69K
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK06 conforming to IEC 50102
StandardsEN/IEC 60947-5-1
UL 508
CSA C22.2 No 14
EN/ISO 13850
EN/IEC 60947-5-5
JIS C8201-5-1
EN/IEC 60947-1
EN/IEC 60947-5-4
EN/IEC 60204-1
IEC 60364-5-53
JIS C8201-1
Product certificationsCSA
BV
UL listed
LROS (Lloyds register of shipping)
GL
DNV
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.500 cm
Package 1 Width5.500 cm
Package 1 Length9.000 cm
Package 1 Weight124.300 g
Unit Type of Package 2S03
Number of Units in Package 280
Package 2 Height30.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight10.369 kg
Unit Type of Package 3P06
Number of Units in Package 3640
Package 3 Height75.000 cm
Package 3 Width80.000 cm
Package 3 Length60.000 cm
Package 3 Weight90.949 kg

XB4BVM3

range of product Easy Altivar 610
product or component type Variable speed drive
product specific application Fan, pump, compressor, conveyor
device short name ATV610
variant Standard version
product destination Asynchronous motors
mounting mode Cabinet mount
EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection IP20
type of cooling Forced convection
supply frequency 50…60 Hz +/-5 %
network number of phases 3 phases
[Us] rated supply voltage 380…460 V – 15…10 %
motor power kW 110 kW for normal duty 90 kW for heavy duty
motor power hp 150 hp for normal duty 125 hp for heavy duty
line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
prospective line Isc 50 kA
apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
output frequency 0.0001…0.5 kHz
nominal switching frequency 2.5 kHz
switching frequency 1…8 kHz adjustable
number of preset speeds 16 preset speeds
communication port protocol Modbus serial
option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
output voltage <= power supply voltage
motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
braking to standstill By DC injection
protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface 2-wire RS 485 for Modbus serial
transmission frame RTU for Modbus serial
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization No impedance for Modbus serial
number of addresses 1…247 for Modbus serial
method of access Slave
supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
width 320 mm
height 852 mm 1159 mm with IP21 conformity kit
depth 390 mm
net weight 82 kg
analogue input number 3
analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number 6
discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number 2
analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
relay output number 3
relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation Between power and control terminals
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

XB4BVM4

range of product Easy Altivar 610
product or component type Variable speed drive
product specific application Fan, pump, compressor, conveyor
device short name ATV610
variant Standard version
product destination Asynchronous motors
mounting mode Cabinet mount
EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection IP20
type of cooling Forced convection
supply frequency 50…60 Hz +/-5 %
network number of phases 3 phases
[Us] rated supply voltage 380…460 V – 15…10 %
motor power kW 110 kW for normal duty 90 kW for heavy duty
motor power hp 150 hp for normal duty 125 hp for heavy duty
line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
prospective line Isc 50 kA
apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
output frequency 0.0001…0.5 kHz
nominal switching frequency 2.5 kHz
switching frequency 1…8 kHz adjustable
number of preset speeds 16 preset speeds
communication port protocol Modbus serial
option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
output voltage <= power supply voltage
motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
braking to standstill By DC injection
protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface 2-wire RS 485 for Modbus serial
transmission frame RTU for Modbus serial
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization No impedance for Modbus serial
number of addresses 1…247 for Modbus serial
method of access Slave
supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
width 320 mm
height 852 mm 1159 mm with IP21 conformity kit
depth 390 mm
net weight 82 kg
analogue input number 3
analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number 6
discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number 2
analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
relay output number 3
relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation Between power and control terminals
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

XB4BVM5

range of product Easy Altivar 610
product or component type Variable speed drive
product specific application Fan, pump, compressor, conveyor
device short name ATV610
variant Standard version
product destination Asynchronous motors
mounting mode Cabinet mount
EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection IP20
type of cooling Forced convection
supply frequency 50…60 Hz +/-5 %
network number of phases 3 phases
[Us] rated supply voltage 380…460 V – 15…10 %
motor power kW 110 kW for normal duty 90 kW for heavy duty
motor power hp 150 hp for normal duty 125 hp for heavy duty
line current 201 A at 380 V (normal duty) 175.7 A at 460 V (normal duty) 170 A at 380 V (heavy duty) 149.1 A at 460 V (heavy duty)
prospective line Isc 50 kA
apparent power 140.0 kVA at 460 V (normal duty) 118.8 kVA at 460 V (heavy duty)
continuous output current 211 A at 2.5 kHz for normal duty 173 A at 2.5 kHz for heavy duty
maximum transient current 232 A during 60 s (normal duty) 260 A during 60 s (heavy duty)
asynchronous motor control profile Variable torque standard Optimized torque mode Constant torque standard
output frequency 0.0001…0.5 kHz
nominal switching frequency 2.5 kHz
switching frequency 1…8 kHz adjustable
number of preset speeds 16 preset speeds
communication port protocol Modbus serial
option card Slot A: communication card, Profibus DP V1 Slot A: digital or analog I/O extension card Slot A: relay output card
output voltage <= power supply voltage
motor slip compensation Can be suppressed Adjustable Not available in permanent magnet motor law Automatic whatever the load
acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s S, U or customized
braking to standstill By DC injection
protection type Thermal protection: motor Motor phase break: motor Thermal protection: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
frequency resolution Display unit: 0.1 Hz Analog input: 0.012/50 Hz
electrical connection Control, screw terminal: 0.5…1.5 mm² Line side, screw terminal: 2 x 50…3 x 120 mm² Motor, screw terminal: 3 x 50…3 x 120 mm²
connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
physical interface 2-wire RS 485 for Modbus serial
transmission frame RTU for Modbus serial
transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
type of polarization No impedance for Modbus serial
number of addresses 1…247 for Modbus serial
method of access Slave
supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
local signalling 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage
width 320 mm
height 852 mm 1159 mm with IP21 conformity kit
depth 390 mm
net weight 82 kg
analogue input number 3
analogue input type AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits AI2, AI3 software-configurable temperature probe or water level sensor
discrete input number 6
discrete input type DI1…DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
input compatibility DI1…DI6: logic input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
discrete input logic Positive logic (source): DI1…DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1) Negative logic (sink): DI1…DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1) Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
analogue output number 2
analogue output type Software-configurable current AQ1, AQ2: 0…20 mA, resolution 10 bits Software-configurable voltage AQ1, AQ2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input 2 ms +/- 0.5 ms (DI1…DI6)configurable – discrete input 5 ms +/- 1 ms (DI5, DI6)configurable – pulse input 10 ms +/- 1 ms (AQ1, AQ2) – analog output
accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
relay output number 3
relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation Between power and control terminals
insulation resistance > 1 MOhm 500 V DC for 1 minute to earth
noise level 76 dB conforming to 86/188/EEC
power dissipation in W 2026 W(forced convection) at 380 V, switching frequency 2.5 kHz
operating position Vertical +/- 10 degree
electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs – 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
pollution degree 2 conforming to EN/IEC 61800-5-1
vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
shock resistance 6 gn for 11 ms conforming to IEC 60068-2-27
relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
ambient air temperature for operation -15…45 °C (without derating) 45…60 °C (with derating factor)
operating altitude <= 1000 m without derating 1000…4800 m with current derating 1 % per 100 m
environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
standards EN/IEC 61800-3 Environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 60721-3
marking CE
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Weight 96.344 kg
Package 1 Height 47 cm
Package 1 width 67 cm
Package 1 Length 103 cm

فروشگاه
مقايسه
حساب من