همه محصولات

فیلترها

دسته‌بندی را انتخاب کنید

XB5AW3445

Range of productsHarmony XB5
Product or component typeIlluminated push-button
device short nameXB5
bezel materialDark gray plastic
Fixing collar materialPlastic
Head typeStandard
Mounting diameter22mm
Sale per indivisible quantity1
Shape of signaling head unitRound
Type of operatorSpring return
Profile operatorsRed flush, unmarked
Operator additional informationWith plain lenses
contacts type and composition1 NO + 1 NC
contact operationSlow-break
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1
Light sourcesIncandescent
bulb baseBA 9s
Light block supplyVia integral transformer 1.2 VA 6 V
[Us] rated supply voltage220…240 V AC 50/60 Hz
Cap/operator or lens colorEd
Height42mm
Width30mm
Depth101mm
Terminals description ISO n°1(21-22)NC
(13-14)NO
net weight0.129 kgs
Resistance to high pressure washers7000000 Pa at 55 °C, distance : 0.1 m
contacts usageStandard contacts
Positive openingWith conforming to EN/IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
operating force3.5 N NC changing electrical state
3.8 N
Mechanical durability10000000 cycles
Tightening torque0.8…1.2 Nm conforming to EN 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC- 13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V
, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C 1000000
cycles , DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5 -4
Signaling typeSteady
presentation devicesComplete product
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…55 °C
Overvoltage categoryClass II conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP69
IP69K
IP67
NEMA degrees of protectionNEMA 13
NEMA 4X
IK degree of protectionIK05 conforming to IEC 50102
StandardsEN/IEC 60947-1
UL 508
EN/IEC 60947-5-4
EN/IEC 60947-5-1
JIS C8201-5-1
CSA C22.2 No 14
JIS C8201-1
product certificationsLROS (Lloyds register of shipping)
DNV
UL listed
GL
CSA
BV
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height12.8cm
Package 1 Width3.4cm
Package 1 Length4.8cm
Package 1 Weight129.0 g

XB5AW35B1

Range of productHarmony XB5
Product or component typeIlluminated push-button
device short nameXB5
bezel materialDark grey plastic
Fixing collar materialPlastic
Head typeStandard
Mounting diameter22 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatorSpring return
Operator profileOrange flush, unmarked
Operator additional informationWith plain lens
contacts type and composition1 NO
contact operationSlow-break
Light sourceUniversal LED
[Us] rated supply voltage24 V AC/DC 50/60 Hz
Cap/operator or lens colourOrange
Terminals description ISO n°1(21-22)NC
(13-14)NO
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
contacts usageStandard contacts
Positive openingWith conforming to EN/IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Operating force3.5 N NC changing electrical state
3.8 N
Mechanical durability10000000 cycles
Tightening torque0.8…1.2 N.m conforming to EN 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4
Signalling typeSteady
Supply voltage limits19.2…30 V DC
21.6…26.4 V AC
current consumption18 mA
Service life100000 h at rated voltage and 25 °C
Surge withstand1 kV conforming to IEC 61000-4-5
device presentationComplete product
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Overvoltage categoryClass II conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP69
IP69K
IP67
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK05 conforming to IEC 50102
StandardsUL 508
EN/IEC 60947-1
EN/IEC 60947-5-4
JIS C8201-5-1
EN/IEC 60947-5-1
CSA C22.2 No 14
JIS C8201-1
product certificationsDNV
UL listed
BV
CSA
GL
LROS (Lloyds register of shipping)
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Resistance to fast transients2 kV conforming to IEC 61000-4-4
Resistance to electromagnetic fields10 V/m conforming to IEC 61000-4-3
Resistance to electrostatic discharge6 kV on contact (on metal parts) conforming to IEC 61000-4-2
8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Electromagnetic emissionClass B conforming to IEC 55011
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.8 cm
Package 1 Width3.4 cm
Package 1 Length5.4 cm
Package 1 Weight50.0 g

XB5FA11

AttributeValue
Mounting TypeFlush Mount
Contact ConfigurationSPST
Push Button StyleRound
Push Button ColourWhite
Panel Cut Out Diameter30mm
SeriesXB5
IP RatingIP69
Push Button MaterialPlastic
Push Button Diameter36.6mm
Better World ProductYes
Operating Temperature Range– 40 → +70°C
Manufacturer Part No.XB5FA11
Terminal TypeScrew
Minimum Operating Temperature-40°C
Better World VerificationGreen Premium
Maximum AC Voltage600V
Maximum DC Voltage600V
Body MaterialPlastic
Maximum Operating Temperature+70°C

XB5FA51C0

Number of command points1
shape of the buttonflat
color of the buttonred
design of the lensaround
hole diameter30.5mm
Suitable for lightingno
Switching function latchingno
gropingYes
supply voltage of the lamp0v
Number of contacts as normally open1
Execution of the electrical connectionscrew connection
With front ringYes
Material of the front ringplastic
Color front ringblack
IP protection)IP66
Degree of protection (NEMA)4X

XB5FA61

Range of productsHarmony XB5
Product or component typePush-button
device short nameXB5F
Product compatibilityZBYF2101
ZBYF4101
ZBYF6101
ZBYF6102
ZBZF32
ZBZF33
ZB4FBZ007
Material bezelsPlastic
Dark gray plastic
Head typeBuilt-in-flush
Fixing collar materialPlastic
mounting diameter30.5mm
Sale per indivisible quantity1
Shape of signaling unit headRounds
Type of operatorSpring returns
Profile operatorsBlue flush, unmarked
Contacts type and composition1 NO
contact operationSlow-break
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable ends conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable ends conforming to EN/IEC 60947-1
Heights42mm
widths36.6mm
depth55mm
Terminals description ISO n°1(13-14)NO
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Contacts usageStandard contacts
Positive openingWithout
Operating travel2.6 mm (NO changing electrical state)
4.3 mm (total travel)
operating force3.8 N NO changing electrical state
Mechanical durability10000000 cycles
Tightening torque0.8…1.2 Nm conforming to EN 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC- 13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000 cycles AC-15, 3 A at 120 V,
operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C
1000000 cycles AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C
1000000 cycles DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000
cycles DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V and 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA in clean environment conforming to EN/IEC 60947-5 -4
Presentation devicesComplete product
CustomizableNo
Customizable1
GCR BRIDGEXB5FACUST01
Compatibility codeXB5
Protective treatmentTh
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Overvoltage categoriesClass II conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP67
IP69
IP69K
Type 13 conforming to UL 50 E
Type 12 conforming to UL 50 E
Type 4 conforming to UL 50 E
Type 4X conforming to UL 50 E
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK03 conforming to IEC 50102
StandardsEN/IEC 60947-1
UL 508
JIS C8201-5-1
EN/IEC 60947-5-4
EN/IEC 60947-5-1
CSA C22.2 No 14
JIS C8201-1
ISO 22196:2011
ISO 21702
Product certificationsUL listed
CSA
vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
2 mm peak to peak (f= 2…10 Hz) conforming to IEC 60068-2-6
shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
25 gn (duration = 6 ms) for 1000 shocks on each axis conforming to IEC 60068-2-27
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.3cm
Package 1 width5.3cm
Package 1 Length8.6cm
Package 1 Weight43.0 g
Unit Type of Package 2S02
Number of Units in Package 240
Package 2 Heights15.0cm
Package 2 Widths30.0cm
Package 2 lengths40.0cm
Package 2 Weight2015 kg

XB5FACUST02

Range of productHarmony XB5
Product or component typePush-button
device short nameXB5
Mounting diameter22 mm
Device presentationComplete product
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.6 cm
Package 1 Width4.3 cm
Package 1 Length5.2 cm
Package 1 Weight43.0 g

XB5FLCUST02

Main
range of productHarmony XB5
product or component typePush-button
device short nameXB5
mounting diameter22 mm
device presentationComplete product

XB5FW31G5

Range of productHarmony XB5
Product or component typeIlluminated push-button
device short nameXB5F
Bezel materialDark grey plastic
Fixing collar materialPlastic
Head typeBuilt-in-flush
Mounting diameter30.5 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatorSpring return
Operator profileWhite flush, unmarked
Operator additional informationWith plain lens
Contacts type and composition1 NO + 1 NC
Contact operationSlow-break
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1
Light sourceUniversal LED
Bulb baseIntegral LED
[Us] rated supply voltage110…120 V AC 50/60 Hz
Cap/operator or lens colourWhite
Height42 mm
Width36.6 mm
Depth55 mm
Terminals description ISO n°1(21-22)NC
(13-14)NO
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Contacts usageStandard contacts
Positive openingWith conforming to EN/IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Operating force3.5 N NC changing electrical state
3.8 N
Mechanical durability10000000 cycles
Tightening torque0.8…1.2 N.m conforming to EN 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4
Signalling typeSteady
Supply voltage limits100…132 V AC
Current consumption14 mA
Service life100000 h at rated voltage and 25 °C
Surge withstand1 kV conforming to IEC 61000-4-5
Device presentationComplete product
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Overvoltage categoryClass II conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP67
IP69
IP69K
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK03 conforming to IEC 50102
StandardsEN/IEC 60947-1
UL 508
JIS C8201-5-1
EN/IEC 60947-5-4
EN/IEC 60947-5-1
CSA C22.2 No 14
JIS C8201-1
ISO 22196:2011
ISO 21702
Product certificationsUL listed
CSA
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Resistance to fast transients2 kV conforming to IEC 61000-4-4
Resistance to electromagnetic fields10 V/m conforming to IEC 61000-4-3
Resistance to electrostatic discharge6 kV on contact (on metal parts) conforming to IEC 61000-4-2
8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Electromagnetic emissionClass B conforming to IEC 55011
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height5.33 cm
Package 1 Width4.32 cm
Package 1 Length9.14 cm
Package 1 Weight0.06 kg

XB5FW33M5C0

Range of ProductHarmony XB5
Product or Component TypeIlluminated push-button
device short nameXB5F
Bezel materialPlastic colour plated grey
Fixing collar materialPlastic
Head typeBuilt-in-flush
Mounting diameter1.20 in (30.5 mm)
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatorSpring return
Operator profileGreen flush, unmarked
Operator additional informationWith plain lens
Contacts type and composition1 NO + 1 NC
Contact operationSlow-break
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable end EN/IEC 60947-1
Light sourceUniversal LED
Bulb baseIntegral LED
[Us] rated supply voltage220…240 V AC 50/60 Hz
Cap/operator or lens colourGreen
Height1.65 in (42 mm)
Width1.44 in (36.6 mm)
Depth2.17 in (55 mm)
Terminals description ISO n°1(21-22)NC
(13-14)NO
Resistance to high pressure washer1015.26 psi (7000000 Pa) 131 °F (55 °C) 0.1 m
Contacts usageStandard contacts
Positive openingWith EN/IEC 60947-5-1 appendix K
Operating travel0.06 in (1.5 mm) NC changing electrical state)
0.10 in (2.6 mm) NO changing electrical state)
0.17 in (4.3 mm) total travel)
Operating force3.5 N NC changing electrical state
3.8 N
Mechanical durability10000000 cycles
Tightening torque7.08…10.62 lbf.in (0.8…1.2 N.m) EN 60947-1
Shape of screw headCross Philips no 1
Cross pozidriv No 1
Slotted flat Ø 4 mm
Slotted flat Ø 5.5 mm
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse gG EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V 3)EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV EN/IEC 60947-1
[Ie] rated operational current3 A 240 V, AC-15, A600 EN/IEC 60947-5-1
6 A 120 V, AC-15, A600 EN/IEC 60947-5-1
0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1
0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1
0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1
1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A 230 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A 120 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A 110 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A 24 V 3600 cyc/h 0.5 EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) 5 V, 1 mA in clean environment EN/IEC 60947-5-4
Λ < 10exp(-8) 17 V, 5 mA in clean environment EN/IEC 60947-5-4
Signalling typeSteady
Supply voltage limits195…264 V AC
Current Consumption14 mA
Service life100000 h at rated voltage and 25 °C
Surge withstand1 kV IEC 61000-4-5
Device presentationComplete product
Protective treatmentTH
Ambient Air Temperature for Storage-40…158 °F (-40…70 °C)
Ambient Air Temperature for Operation-40…158 °F (-40…70 °C)
Overvoltage categoryClass II IEC 60536
IP degree of protectionIP66 IEC 60529
IP67
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK03 IEC 50102
StandardsEN/IEC 60947-1
UL 508
JIS C8201-5-1
EN/IEC 60947-5-4
EN/IEC 60947-5-1
CSA C22.2 No 14
JIS C8201-1
Product CertificationsUL Listed
CSA
Vibration resistance5 gn 2…500 Hz)IEC 60068-2-6
Shock resistance30 gn 18 ms) half sine wave acceleration IEC 60068-2-27
50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Resistance to fast transients2 kV IEC 61000-4-4
Resistance to electromagnetic fields9.14 V/m (10 V/m) IEC 61000-4-3
Resistance to electrostatic discharge6 kV on contact (on metal parts) IEC 61000-4-2
8 kV in free air (in insulating parts) IEC 61000-4-2
Electromagnetic emissionClass B IEC 55011
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height3.39 in (8.6 cm)
Package 1 Width1.69 in (4.3 cm)
Package 1 Length2.05 in (5.2 cm)
Package 1 Weight1.83 oz (52.0 g)

XB5FW35G5

Range of productHarmony XB5
Product or component typeIlluminated push-button
device short nameXB5F
Bezel materialDark grey plastic
Fixing collar materialPlastic
Head typeBuilt-in-flush
Mounting diameter30.5 mm
Sale per indivisible quantity1
Shape of signaling unit headRound
Type of operatorSpring return
Operator profileOrange flush, unmarked
Operator additional informationWith plain lens
Contacts type and composition1 NO + 1 NC
Contact operationSlow-break
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1
Light sourceUniversal LED
Bulb baseIntegral LED
[Us] rated supply voltage110…120 V AC 50/60 Hz
Cap/operator or lens colourOrange
Height42 mm
Width36.6 mm
Depth55 mm
Terminals description ISO n°1(21-22)NC
(13-14)NO
Resistance to high pressure washer7000000 Pa at 55 °C, distance : 0.1 m
Contacts usageStandard contacts
Positive openingWith conforming to EN/IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Operating force3.5 N NC changing electrical state
3.8 N
Mechanical durability10000000 cycles
Tightening torque0.8…1.2 N.m conforming to EN 60947-1
Shape of screw headCross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage600 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to EN/IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to EN/IEC 60947-5-4
Signalling typeSteady
Supply voltage limits100…132 V AC
Current consumption14 mA
Service life100000 h at rated voltage and 25 °C
Surge withstand1 kV conforming to IEC 61000-4-5
Device presentationComplete product
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
Overvoltage categoryClass II conforming to IEC 60536
IP degree of protectionIP66 conforming to IEC 60529
IP67
IP69
IP69K
NEMA degree of protectionNEMA 13
NEMA 4X
IK degree of protectionIK03 conforming to IEC 50102
StandardsEN/IEC 60947-1
UL 508
JIS C8201-5-1
EN/IEC 60947-5-4
EN/IEC 60947-5-1
CSA C22.2 No 14
JIS C8201-1
ISO 22196:2011
ISO 21702
Product certificationsUL listed
CSA
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Resistance to fast transients2 kV conforming to IEC 61000-4-4
Resistance to electromagnetic fields10 V/m conforming to IEC 61000-4-3
Resistance to electrostatic discharge6 kV on contact (on metal parts) conforming to IEC 61000-4-2
8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Electromagnetic emissionClass B conforming to IEC 55011
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.3 cm
Package 1 Width5.3 cm
Package 1 Length8.6 cm
Package 1 Weight52.0 g

XB5FWCUST01

Range of productHarmony XB5
Product or component typeIlluminated push-button
device short nameXB5
Mounting diameter22 mm
Device presentationComplete product
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8.6 cm
Package 1 Width4.3 cm
Package 1 Length5.2 cm
Package 1 Weight52.0 g

XB7NA11341

Range of productHarmony XB7
Product or component typePush-button
device short nameXB7
Mounting diameter22 mm
Sale per indivisible quantity10
IP degree of protectionIP20 (rear face) conforming to IEC 60529
IP65 (front face) conforming to IEC 60529
Shape of signaling unit headRound
Type of operatorSpring return
Operator profileWhite flush, up arrow (black)
Contacts type and composition1 NO
Connections – terminalsScrew clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.34…2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1
Device presentationMonolithic product
CAD overall width29 mm
CAD overall height29 mm
CAD overall depth51.5 mm
Terminals description ISO n°1(13-14)NO
Product weight0.021 kg
Device mountingFixing hole – diameter: 22.5 mm 22.3 +0.4/0 conforming to EN/IEC 60947-1
Fixing center>= 30 x 40 mm (support panel) metal – thickness: 1…6 mm
>= 30 x 40 mm (support panel) plastic – thickness: 2…6 mm
Fixing modeFixing nut beneath head: 2…2.4 N.m
Contact operationSlow-break
Positive openingWith (only NO)
Mechanical durability1000000 cycles
Tightening torque0.8…1.2 N.m conforming to EN 60947-1
Shape of screw headCross compatible with JIS No 1 screwdriver
Cross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Short-circuit protection4 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
[Ui] rated insulation voltage250 V (pollution degree 3) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage4 kV conforming to EN/IEC 60947-1
[Ie] rated operational current0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1
0.22 A at 125 V, DC-13, R300 conforming to EN/IEC 60947-5-1
0.3 A at 240 V, AC-14, D300 conforming to EN/IEC 60947-5-1
0.6 A at 120 V, AC-14, D300 conforming to EN/IEC 60947-5-1
Electrical durability1000000 cycles, DC-13, 0.3 A at 24 V, operating rate <216000 cyc/mn, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 0.03 A at 230 V, operating rate <216000 cyc/mn, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 0.09 A at 240 V, operating rate <108000 cyc/mn, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Electrical reliabilityΛ <= 10exp(-6) at 17 V, 5 mA conforming to EN/IEC 60947-5-4
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-25…70 °C
Overvoltage categoryClass II conforming to IEC 61140
NEMA degree of protectionNEMA 12 conforming to UL 50 E
NEMA 3 conforming to UL 50 E
StandardsJIS C8201-5-1
EN/IEC 60947-5-1
UL 508
CSA C22.2 No 14
EN/IEC 60947-1
JIS C8201-1
Product certificationsCCC
GOST
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height8 cm
Package 1 Width5 cm
Package 1 Length15 cm
Package 1 Weight20 g

فروشگاه
مقايسه
حساب من